34-059-20324

Well Details

Well ID: 34-059-20324
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Liberty Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: WALKER RAGAN D
License Status: Storage Well
License Date:
Spud Date: 1942-11-19
Spud Drilling Contractor:
Final Drill Date: 1942-12-23
Well Total Depth: 3286.00 ft
Configuration: Vertical
Latitude: 40.150000
Longitude: -81.610000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1942-11-19 809.4 GL
Completed 1942-12-23 809.4 GL
Reached Total Depth 1942-12-23 809.4 GL
Change of Owner 2011-08-17 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-22 809.4 GL

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1593194859 2019-4-18 0:00: SO No Violations 0.20
-1634603927 2016-10-19 0:00 SO No Violations 0.50
-369550775 2019-8-15 0:00: SO No Violations 0.50
-41614495 2016-4-12 0:00: SO No Violations 5.50
-629124788 2018-10-31 0:00 SO No Violations 0.10
-805765466 2016-4-13 0:00: SO No Violations 1.00
-84464753 2019-8-15 0:00: SO No Violations 0.70
0041614495 2016-04-12 Storage Well No Violations On the day of my inspection I was on location for the topping off of the 7 inch surface casing. I witnessed that Hagan Well Service was on site and ran 1 inch tubing inside the 10 inch conductor pipe tagging up at 50 feet. C & J Services was on site and cemented the 7 inch surface casing with 200 sacks of Class A cement weighing 15.6ppg and a yield of 1.18cuft/sack. Cement weight was verified with pressurized mud scales and 5bbls of cement was circulated to surface. HWS will install a WDI 5000psi wellhead in preparation for upcoming re-frac of the well.
0531668326 2017-10-05 Storage Well No Violations On the day of my inspection I witnessed that the well was equipped with 7 inch diameter casing with valves in the open position and well identification was present with no violations.
0629124788 2018-10-31 Storage Well No Violations The purpose of my inspection was a status check on a natural gas storage well. During my inspection the well was equipped with 6.625-inch diameter casing with a flange casing head, a master valve, and a 3.5-inch diameter steel line leading to a drip tank. Identification was located at the wellhead.
0782297584 2015-02-04 Storage Well No Violations On the day of my inspection I witnessed that the well was equipped with 6.625 inch casing with valves in the open position and well identification was present with no violations.
0805765466 2016-04-13 Storage Well No Violations On the day of my inspection I witnessed the 5000psi wellhead was installed, pressured tested to 2000psi and the cement remained at the surface. Hagan Well Service will retrieve bridge plug tomorrow and turn well back over to Columbia Gas.
1440075649 2015-08-20 Storage Well No Violations There were no violations during the time of my inspection. Well was properly identified.
1593194859 2019-04-18 Storage Well No Violations The purpose of my inspection was a status check on a natural gas storage well. During my inspection the well was equipped with 6.625-inch diameter casing with a flange casing head, a master valve, and a 3.5-inch diameter steel line leading to a drip tank. Identification was legible and correct was located at the wellhead.
1634603927 2016-10-19 Storage Well No Violations On the day of my inspection I witnessed that the well was equipped with 7 inch casing with valves in the open position and well identification was present with no violations.
2009306964 2016-01-28 Storage Well No Violations My inspection today found this well to be in compliance, with no issues of concern. Required identification is attached to the well and the main valve is in the closed position.
2063791760 2013-10-21 Storage Well No Violations On the day of my inspection I witnessed that the valves were closed and the well identification was incorrect. Working with Columbia gas to correct the identification.
2144915173 2020-4-2 0:00:0 SO No Violations 0.50
531668326 2017-10-5 0:00: SO No Violations 0.50
782297584 2015-2-4 0:00:0 SO No Violations 0.50