34-055-22065

Well Details

Well ID: 34-055-22065
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Parkman Township
Operator Name: DJR WELL SERVICES INC.
Well Pad ID:
Farm/Lease Name: TROYER UNIT
License Status: Producing
License Date: 2008-08-01
Spud Date: 2008-08-02
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING
Final Drill Date: 2008-08-07
Well Total Depth: 4370.00 ft
Configuration: Vertical
Latitude: 41.400000
Longitude: -81.030000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-08-01 Proposed Formations:CLINTON, Issued Date:8/1/2008, Expired Date:8/1/2009 6:00:00 AM, Drilling unit acres:82.52, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-08-07 INITIAL PRODUCTION BASED ON REGIONAL AVERAGE
Completion Report Received 2009-02-03 INITIAL PRODUCTION BASED ON REGIONAL AVERAGE
Construction Permit Expires 2009-08-01 INITIAL PRODUCTION BASED ON REGIONAL AVERAGE
Record Last Modified 2017-02-15 INITIAL PRODUCTION BASED ON REGIONAL AVERAGE

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-03-12 4097 4148 20
4097 4148 20
4097 4148 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 69000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 WILKES ENERGY INC 0.00 221.00 365
2009 WILKES ENERGY INC 1427.00 947.00 255
2010 WILKES ENERGY INC 4050.00 1245.00 255
2011 WILKES ENERGY INC 2400.00 838.00 365
2012 WILKES ENERGY INC 2245.00 1349.00 366
2013 WILKES ENERGY INC 1680.00 606.00 365
2014 WILKES ENERGY INC 1936.00 546.00 365
2015 WILKES ENERGY INC 1847.00 530.00 365
2016 WILKES ENERGY INC 1448.00 394.00 365
2017 WILKES ENERGY INC 1214.00 509.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 WILKES ENERGY INC Brine 0 365
2009 WILKES ENERGY INC Brine 637 255
2010 WILKES ENERGY INC Brine 275 255
2011 WILKES ENERGY INC Brine 207 365
2012 WILKES ENERGY INC Brine 236 366
2013 WILKES ENERGY INC Brine 165 365
2014 WILKES ENERGY INC Brine 192 365
2015 WILKES ENERGY INC Brine 108 365
2016 WILKES ENERGY INC Brine 70 365
2017 WILKES ENERGY INC Brine 94 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1408121204 2008-8-2 0:00:0 DD No Violations
-1840697382 2008-8-8 0:00:0 DD No Violations
-790279529 2008-8-2 0:00:0 DD No Violations
-9762277 2008-8-4 0:00:0 DD No Violations
0009762277 2008-08-04 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pits and the pit liners were in good shape. The location was in good shape. There were no violations at this time.
0790279529 2008-08-02 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 11 3/4 conductor pipe. I found no violations at this time.
1218201565 2008-08-07 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pit liners were in good shape. The location was in good shape. There were no violations at this time.
1352992960 2008-08-04 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 8 5/8 casing. There were no violations at this time.
1365086540 2013-04-04 Preliminary Restoration No Violations My inspection found the well to be equipped with a pump jack. The annulus valve was open. The well and tank battery are in good repair. The tank battery consists of two 100 BBL production tanks, two 35 BBL poly brine tanks, and a mechanical separator. One of the 35 BBL poly brine tanks has a damaged top and was not plumbed into any other tank. I contacted the well tender to have the tank removed. The proper identification is located on the tank battery. The lease road is in stable condition. The area has been graded, seeded, and vegetation has established. Preliminary restoration has passed.
1408121204 2008-08-02 Drill / Deepen / Reopen No Violations I preformed a rig inspection. I GPSd the well. The pits and pit liners were in good shape. The location was in good shape. There were no violations at this time.
1416925194 2014-11-21 Production Wells No Violations My inspection found the well to be equipped with a pumpjack. The annulus valve was open. The well and tank battery are in good repair. The tank battery consists of two 100 BBL production tanks, two 35 BBL poly brine tanks, and a mechanical separator. One of the 35 BBL poly brine tanks has a damaged top and was not plumbed into any other tank. I contacted the well tender to have the tank removed. The proper identification is located on the tank battery. The lease road is in stable condition.
1840697382 2008-08-08 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 4 1/2 casing. There were no violations at this time.

For data sources see[9]

References