X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22061

Well Details

Well ID: 34-055-22061
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Parkman Township
Operator Name: DJR WELL SERVICES INC.
Well Pad ID:
Farm/Lease Name: YODER-SOLTIS UNIT
License Status: Producing
License Date: 2008-07-18
Spud Date: 2008-08-14
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING
Final Drill Date: 2008-08-19
Well Total Depth: 4212.00 ft
Configuration: Vertical
Latitude: 41.420000
Longitude: -81.010000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-07-18 Proposed Formations:CLINTON, Issued Date:7/18/2008, Expired Date:7/18/2009 6:00:00 AM, Drilling unit acres:89.5, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-08-19 INITIAL PRODUCTION BASED ON REGIONAL AVERAGE
Completion Report Received 2009-01-30 INITIAL PRODUCTION BASED ON REGIONAL AVERAGE
Construction Permit Expires 2009-07-18 INITIAL PRODUCTION BASED ON REGIONAL AVERAGE
Record Last Modified 2017-02-15 INITIAL PRODUCTION BASED ON REGIONAL AVERAGE

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-03-12 3970 4008 22
3970 4008 22
3970 4008 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 69000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 WILKES ENERGY INC 0.00 0.00 0
2009 WILKES ENERGY INC 5828.00 618.00 320
2010 WILKES ENERGY INC 10498.00 791.00 320
2011 WILKES ENERGY INC 6842.00 445.00 365
2012 WILKES ENERGY INC 5488.00 479.00 366
2013 WILKES ENERGY INC 3760.00 381.00 365
2014 WILKES ENERGY INC 2990.00 305.00 365
2015 WILKES ENERGY INC 2420.00 231.00 365
2016 WILKES ENERGY INC 1762.00 207.00 365
2017 WILKES ENERGY INC 1444.00 279.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 WILKES ENERGY INC Brine 0 0
2009 WILKES ENERGY INC Brine 541 320
2010 WILKES ENERGY INC Brine 383 320
2011 WILKES ENERGY INC Brine 283 365
2012 WILKES ENERGY INC Brine 193 366
2013 WILKES ENERGY INC Brine 158 365
2014 WILKES ENERGY INC Brine 123 365
2015 WILKES ENERGY INC Brine 95 365
2016 WILKES ENERGY INC Brine 111 365
2017 WILKES ENERGY INC Brine 152 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1420151550 2008-8-19 0:00: DD No Violations
-520413861 2008-8-19 0:00: DD No Violations
-917029322 2008-8-15 0:00: DD No Violations
-926409495 2019-7-23 0:00: PW No Violations 0.60
-977636481 2008-8-15 0:00: DD No Violations
0520413861 2008-08-19 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pit liners and the location were in good shape. There were no violations at this time.
0917029322 2008-08-15 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pit liners and the location were in good shape. There were no violations at this time.
0977636481 2008-08-15 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 8 5/8 casing. I found no violations at this time.
1218820808 2008-08-14 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 11 3/4 conductor pipe. There were no violations at this time.
1243341528 2009-09-09 Preliminary Restoration No Violations Well is a pump jack well. Site has been graded and seeded. Site is stable and in good repair.
1291794730 2013-03-25 Production Wells No Violations The well is equipped with a pump jack. The well and tank battery is in good repair. The tank battery consists of two 100 BBL production tanks, a 50 BBL poly brine tank, and a mechanical separator. The proper identification sign is located on the tank battery. The lease road is in stable condition. The lease road and tank battery are being shared by permit # 2-2069.
1420151550 2008-08-19 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 4 1/2casing. There were no violations at this time.
1637185082 2012-02-17 Production Wells No Violations Well and tank battery are in good repair.
1961985321 2008-08-14 Drill / Deepen / Reopen No Violations I performed a rig inspection. I GPSd the well. The pit liners were in good shape as well as the location. I found no violations at this time.
2068946179 2012-08-16 Preliminary Restoration No Violations My inspection today was due to a water well complaint at the Byler water well. The water well is within 3000ft of the gas well. My inspection today found a pumping unit well in good repair. The 8.625 annulus was open. The well is produced into the same tank battery as permit 22069. The tank battery has two 140bbl production tanks, one 1500 gallon poly tank and a mechincal separator. Load lines are locked. The tank battery dike was in good repair. The lease road was stable. Identification signs were posted. Review of casing records showed nothing abnormal in the casing or cementing program.

For data sources see[9]

References