Well Details

Well ID: 34-055-22031
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: PETRONZIO MAYFIELD
License Status: Producing
License Date: 2008-04-11
Spud Date: 2008-05-12
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-05-20
Well Total Depth: 3880.00 ft
Configuration: Vertical
Latitude: 41.520000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-04-11 Proposed Formations:CLINTON, Issued Date:4/11/2008, Expired Date:4/11/2009 6:00:00 AM, Drilling unit acres:22.32, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-05-20
Completion Report Received 2009-02-27
Construction Permit Expires 2009-04-11
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-04-27 3697 3761 25
3697 3761 25
3697 3761 25

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 69348 Gal 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC 21895.00 54.00 365
2010 CUTTER EXPLORATION INC 40608.00 64.00 365
2011 CUTTER EXPLORATION INC 29528.00 41.00 0
2012 CUTTER EXPLORATION INC 22576.00 0.00 366
2013 CUTTER EXPLORATION INC 29447.00 54.00 365
2014 CUTTER EXPLORATION INC 33758.00 0.00 365
2015 CUTTER EXPLORATION INC 21257.00 0.00 365
2016 CUTTER EXPLORATION INC 12340.00 35.00 365
2017 CUTTER EXPLORATION INC 0.00 9687.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC Brine 226 365
2010 CUTTER EXPLORATION INC Brine 131 365
2011 CUTTER EXPLORATION INC Brine 30
2012 CUTTER EXPLORATION INC Brine 93 366
2013 CUTTER EXPLORATION INC Brine 0 365
2014 CUTTER EXPLORATION INC Brine 75 365
2015 CUTTER EXPLORATION INC Brine 45 365
2016 CUTTER EXPLORATION INC Brine 0 365
2017 CUTTER EXPLORATION INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1193009415 2008-5-12 0:00: DD No Violations
-1289599797 2008-5-6 0:00:0 DD No Violations
-1300613793 2016-6-24 0:00: UP No Violations
-1467920224 2013-5-28 0:00: UP No Violations
-1677938890 2018-11-2 0:00: UP No Violations
-1740919555 2008-5-22 0:00: DD No Violations
-1903250344 2008-7-30 0:00: DD No Violations
-515085684 2010-6-3 0:00:0 PW No Violations
-772268456 2013-6-12 0:00: UP No Violations
-801371707 2008-5-21 0:00: DD No Violations
0159524104 2008-08-13 Preliminary Restoration No Violations On site with adjacent land owner and Jay Cheslock DMRM supervisor. Operator has graded and seeded site. Operator has used seed fabric in the drainage ditches to hold vegetation. Vegetation is established at this time. Operator encountered a drain tile on the east side of the site. Operator repaired drain tile. Tile discharges into sedimentation pond, land owner was concerned that the water was of poor quality, water has iron in it. Called Shannon at Geauga soil and water to advice that there maybe a storm water run off issue in the area. Adjacent landowner is part of the unit, his property is non-drill. During the drilling process operator cleared trees and brush from the landowners property, a secondary lease agreement was made between the landowner and company. Landowner wants trees replaced, this is a civil issues between the company and the landowner. Operator has complete drainage control repairs on the adjacent landowners property, work to be completed in lease agreement. Landowner stated that he has had a change in the quality of water coming from his well. Landowner stated that he had an agreement in the lease if he has a change in well water quality. Operator had well tested before drilling, I advised landowner to contact the company for a post test of his well water, if the company does not correct the issues to contact DMRM and we will start an investigation.
0342659122 2008-05-09 Drill / Deepen / Reopen No Violations On site to meet with adjacent landowner and company. Mr. Roller is the landowner to the south of the site. His property is in the drilling unit. He is a no drill lease holder. Operator has cleared an area approximately 30 X 50 on his property. Operator is planning on constructing part of the pit on his property. Land owner is first upset that they have cleared part of his land without permission, second that drainage flowing towards his property has been changed. Per the landowner any changes to drainage in the area increase flooding on his property. There is a sediment pond on the Petronzio property adjacent to the site. It was agreed that the pond would be cleaned out and a spillway constructed for the pond once drilling is complete. Ponds spill way has been washed out. A well constructed spillway will increase the capacity of the pond by about a foot in depth. Operator agrees to construct an additional catch basin on Mr. Rollers property to slow water flowing towards him. Mr. Roller has a small pond on his property that all the drainage form the affected area flows into. It was agreed between the operator and the land owner, that the entrance points to the pond will be improved and rock lined. Landowner was concerned about what types of trees were removed from his property and the quality of the trees. I was on site when property was being cleared and for the pre-site. Land was covered with brush: multiflora rose, honeysuckle and small trees, many of which had multiple stems. All cleared brush and trees were of a size that could be chipped. Operator talked over reclamation with Mr. Roller, regarding planting hardwoods on his property to make up for the clearing. Operator will submit a new lease agreement to Mr. Roller for his review. Mr. Roller agrees that part of the pit can be constructed on his property.
0355280838 2008-05-12 Drill / Deepen / Reopen No Violations On site at 10:00pm for CND job. Operator ran two joints of pipe, third joint was getting hung up. Operator attempted to turn joint down. Wash joint down, joint was hitting solid. Operator decided to trip pipe out and clean hole with bit. Operator will call when hole is cleaned. Left site.
0515085684 2010-06-03 Production Wells No Violations On site with Geauga Soil and Water to review drainage controls. Mr. Roller, a landowner to the west of the location had flooding over the weekend. Mary Roller contacted me 06/01/2010 regarding the flooding. National Weather Charts showed that the flood event was a 250 year event. During the reclamation of the site the operator built two drainage swales on the affected area, directing drainage north and west. One swale discharges directly into a pond on Mr. Rollers property. The 2nd swale discharges into a pond, north west of the well site. The pond also discharges into the pond on Mr. Rollers property. The pond adjacent to the well is approximately 35 feet X 31 feet (0.02 acres,) with an unknown depth, the pond does not have a primary or emergency spillway. This pond also receives drainage from the north, off of the shopping centers parking lot. Well site receives drainage from a parking lot to the east of the location, that flows west across it. The pond on Mr. Rollers property is approximately 40 feet X 30 feet and 6 feet deep (0.027 acres.) The pond on Mr. Rollers property has a 4 inch over flow pipe in it, no primary or emergency spillway. The pipe flows into a drain tile that flows to the road. Well location: vegetation is established on location. Vegetation is established in the drainage swales. Grass in swales had been laid down from the flow of water. Drainage for the surrounding area flows north across the oil and gas well affected area and west. Landowners south of Mr. Rollers property have a drainage swale cut north/south to divert drainage north onto Mr. Rollers property. During well reclamation Mr. Roller had Cutter Exploration cut a drainage ditch approximately 6 to 8 inches deep and 6 to 12 inches wide intending to connect the adjacent landowners drainage swale with his pond. This ditch is intended to prevent water from flowing between the homes and developing its own drainage swale. The drainage swale has two bends in it. Mr. Roller
0690520733 2010-06-01 Production Wells No Violations On site with Chester Zoning to review drainage controls. Mr. Roller, landowner to the west of the location had flooding over the weekend. Mary Roller contacted me regarding the flooding. The flood event was between a 250 and 500 year event. Operator during the reclamation of the site built two drainage swales on the affected area, directing drainage north and west. One swale discharges directly into the pond on Mr. Rollers property, the adjacent land owner. The 2nd swale discharges into the pond, north west of the well site. The pond also discharges into the pond on Mr. Rollers property. The pond adjacent to the well is approximately 35 feet X 31 feet unknown depth, no primary or emergency spillway. This pond also receives drainage from the north, off of the shopping centers parking lot. Site receives drainage from parking lot to the east of the location. The pond on Mr. Rollers property is approximately 40 feet X 30 feet and 6 feet deep. The pond on Mr. Rollers property has a 4 inch over flow pipe in it, no primary or emergency spillway. The pipe flows into a drain tile that flows to the road. Well location: vegetation is established on location. Vegetation is established in the drainage swales. Grass in swales had been laid down from the flow of water. Note: the oil and gas well site doesnt contribute additional drainage to the area, the velocity of the water may have changed coming off of the affected area. Drainage for the surrounding area flows north across oil and gas well affected area and west. Landowners south of Mr. Rollers property have a drainage swale cut north/south to divert drainage north onto Mr. Rollers property. During well reclamation Mr. Roller had Cutter Exploration cut a drainage ditch approximately 6 to 8 inches deep and 6 to 12 inches wide attempting to connect the adjacent landowners drainage swale with his pond. This ditch is to prevent water from flowing between the homes and developing its own drainage swale. The draina
0772268456 2013-06-12 UrbanProduction Wells No Violations I was called to the location by a neighboring land owner about a leak. The kimray regulator was leaking when I arrived. I notified Mark Turpak the well tender for Cutter about the issue. He stated he would be there immediatley to fix the regulator. Nothing else has changed since my last inspection.
0801371707 2008-05-21 Drill / Deepen / Reopen No Violations Rig moving on site. Site is in good repair.
1193009415 2008-05-12 Drill / Deepen / Reopen No Violations On site with landowner, Mr. Roller, adjacent landowner who is in the unit. His lease is a non-drill lease. Operator has built first pit. Pit had surface run off in the bottom, didnt appear any ground water was entering the pit. Landowner was upset additional topsoil had been stockpiled on his property past the agreed amount. Landowner was concerned how much of the pit was going to be on his property. Asked landowner if he want them to stop. Landowner felt that the damage had been done, just wants them to get done. At this time safety fence is not up. Additional drainage controls are need.
1210784541 2008-05-14 Drill / Deepen / Reopen No Violations On site for surface job. Operator has finished running pipe before I arrived, they had completed drilling earlier than planned. Surface pipe was in the hole, operator was circulating on it. Good circulation. One section of 8.625 pipe was on the rack, the pipe was wielded in the center. Spoke to Roy Poulson and a hand on the rig, there had been more pipe like that on the rack and pipe had been ran. Spoke to fellow inspector and supervisor, it is policy that wielded pipe not be ran. Supervisor suggested that if they have evidence that the pipe has been pressure tested and is sound that they can leave it, this time. Pipe must be as good if not better than standard pipe, that is not wielded. Spoke to Lynn Strazi consultant for Cutter, he did not have certification regarding the pipe at this time. Spoke with Dan Allen from Miller Supply. Pipe was gas line pipe. Pipe was cut in 40 sections. New thread collars were wielded to the cut ends of the pipe, other ends were threaded. The wield on the pipe, is where the pipe was wielded when the pipe was installed as a gas line. I asked him if the pipe had been pressure tested, no it had not been. Pipe was new R-3, 20lb pipe when it was installed as a pipe line. Asked Dan if he knew how long it had been in the ground, no he didnt know. I asked Dan if he knew at what pressure it had been operated at, he did not know. I asked Dan Allen if he knew the condition of the pipe right now as it is in the hole, no he did not know. I order pipe to be pulled from the hole and new pipe brought on site. First joint of pipe pulled was a wielded section of pipe. Pipe was pitted and had rust scale. Majority of the joints pulled were wielded pipe, 5, 7 and 8 sections of pipe were wielded pipe. Those joints were pitted and had rust scale.
1211031790 2008-05-17 Drill / Deepen / Reopen No Violations Drill depth 2458. Pits are in good repair. Operator is drilling on fluid. BOP is in place. Pit fluid level is good 2 plus feet of free board. Eric Poulson on site. Drainage controls are in place and functional.
1219780200 2008-08-25 Drill / Deepen / Reopen No Violations On site with Shannon Mullins from Soil and Water, Dan from Cutter, Jay Cheslock DMRM supervisor. On site regarding reclamation on site and a drain tile that was encountered during construction of the site. Drain tile discharges into a settling pond on the west side of the site, bio-film is forming on the surface of the water. There is iron precipitating out of the water and staining the stone in the drainage channel. Tested for Cl- , Cl- reading of 1.8 (52ppm) on low range quantab, ph of the water was 8. Dan, is going to add limestone to the drainage channel, to attempt to clean up the iron. Site will be reassessed in the spring, the 2nd option will be to disconnect the drain tile where it comes out of the parking lot hill side and allow it to flow over the ground to the pond. The hope is that the ground will act like a filter. I called Soil and water regarding this issue, the water is coming from offsite and flows across the site, possible storm water issue. The two adjacent neighbors to the west have complained to the company regarding a change in their well water. Cutter is addressing the issue at this time. Spoke to Dan on 08/26/08 referred Dan to Ahmed Hawari in regards to the water wells. First landowner is complaining of iron film in his well, the 2nd owner is complaining of sand in their well.
1227537878 2008-11-24 Production Wells No Violations Well pumpers on site at the time of inspection. One 100BBL tank and one 1500gal poly tank on site. Well is a rabbit well. Mechanical separator, spacing is good poly tank between separator and production tank. Site is snow covered.
1253647376 2009-09-22 Production Wells No Violations No leaks noted around or in the tank battery and well. Water was condensing on the separator and well head from the gas exchanging. Vapors notes coming out of spark arrestor. 25psi on the annulus, annulus is plumbed into the tank battery. Annulus has a pop-off on it, annulus pressure is above pop-off, it appears vapors are form the annulus. Man doors are locked. No drainage noted site was dry.
1262619981 2009-05-20 Administrative Inspection No Violations E-mail from Warren Shoenfelt Five day annulus test results zero psi.
1289599797 2008-05-06 Drill / Deepen / Reopen No Violations On site to meet with Lynn Straze regarding site construction and changes. Operator will need to construct pits on the east side of the site. Pits will have to be longer and narrow to fit site. Pit placement change was approved by inspector. Operator marked trees to the south of the site to be cleared. Operator had tree company on site clearing and chipping trees. Operator was also using a heavy mower on site to clear the land. Center of the site south of well stack was very soft.
1300613793 2016-06-24 UrbanProduction Wells No Violations I conducted an inspection on this well. The well is equipped with a plunger lift unit and the valves on the wellhead are open. The well is fenced and locked. The tank battery consisted of one, 100 BBL production tank, one, 50 BBL poly brine tank, and a mechanical separator. The 100 BBL tank was equipped with lightening protection and a charcoal filter. The tank battery was diked and fenced. Vegetation within the tank battery needs to be maintained. Signage at the tank battery was clear and legible. The lease access was stable. I contacted Mark Torpak from Cutter with regards to maintenance of the vegetation within the tank battery.
1307454365 2011-05-27 Production Wells No Violations Lease road is stable, board on board fencing in place at tank battery and wellhead. Gates are locked. Dike and spacing in compliance. All lines bullplugged. Lightning arrestor and charcoal filter in place. Vent hatches in place and closed. Production tank hatches closed. Site in good repair, no violations at this time.
1421160582 2015-01-13 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
1467920224 2013-05-28 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open and plumbed into a pop off valve that is plumbed into the production tank. The tank battery and well are in good repair and surrounded by a wood fence. The tank battery consists of a 100 BBL production tank, a 50 BBL poly brine tank, and a mechanical separator. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter. The vent stack is then plumbed up into a spark arrestor. The proper identification is located on the tank battery. The lease road is in stable condition.
159524104 2008-8-13 0:00: PL No Violations
1613746714 2008-05-13 Drill / Deepen / Reopen No Violations On site for second attempt to run conductor pipe. Operator ran the first two joints of CND easy. Third joint hit and stopped at the same depth it has at the last attempt. Operator attempted to work pipe down. Roy decided to trip pipe out again and clean hole out with a 17 inch bit. Left site.
1672170131 2008-05-13 Drill / Deepen / Reopen No Violations On site at 9:00am operator was two driller collars down with the 17 inch bit.
1677938890 2018-11-02 UrbanProduction Wells No Violations I conducted an inspection on this well. The well was equipped with a plunger lift assembly and in production. The well was fenced with a locked man door. The tank battery was comprised of one 100 BBL tank, one 50 BBL tank and a mechanical separator. The diked tank battery was fenced with a locked man door. Legible signage was located at the tank battery and the lease access was stable.
1740919555 2008-05-22 Drill / Deepen / Reopen No Violations surface
1876700632 2008-05-13 Drill / Deepen / Reopen No Violations On site for third attempt of CND job. Operator finished cleaning hole with 17 inch bit. TD at 123 operator ran 100 of 11.75 inch new 32lb pipe. Pipe ran well good circulation. While operator was hooking up to cement it was noted that there were a few large bubbles coming up around the conductor pipe. Not known if it was gas or the heavy gel settling. Hole was static after cement was ran. Cement held at surface. Operator broke circulation, mixed cement till we saw it. Cement returned to surface then operator displaced. Very good return of cement to surface. Operator has installed additional drainage controls on site. Silt fence has been added to the backside of overburden and topsoil stockpiles. Operator used a mix of straw bails and silt fence with drainage ditches in the area. Operator installed safety fence a the top of the hill.
1903250344 2008-07-30 Drill / Deepen / Reopen No Violations Pits have been closed. Pit are has been seeded and mulched. Operator has constructed a landscape wall around the tank battery location. Pine trees have been planted on the landscape wall. Trees are starting to slump down the side of the wall.
1993905435 2016-10-19 UrbanProduction Wells No Violations I conducted a follow-up inspection on this well from the last inspection conducted on 6/24/2016. The well is equipped with a plunger lift unit and the valves on the wellhead are open. The well is fenced and locked. The tank battery consisted of one, 100 BBL production tank, one, 50 BBL poly brine tank, and a mechanical separator. The 100 BBL tank was equipped with lightening protection and a charcoal filter. The tank battery was diked and fenced. Vegetation within the tank battery needed to be maintained. At the time of this inspection, the vegetation within the tank battery had been maintained. Signage at the tank battery was clear and legible. The lease access was stable.
2077146718 2009-08-05 Preliminary Restoration No Violations Well and tank battery are in good repair. 100BBL tank was venting through the charcoal filter. Vapors were visible, tank had just been painted. Called Mike Cutter left message to have pumper check well. Battery was in the direct sunlight. Landscaping and seeding is in good repair.
342659122 2008-5-9 0:00:0 DD No Violations
355280838 2008-5-12 0:00: DD No Violations
690520733 2010-6-1 0:00:0 PW No Violations

For data sources see[9]

References