X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22015

Well Details

Well ID: 34-055-22015
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: OSAIR INC
Well Pad ID:
Farm/Lease Name: BUBBA
License Status: Plugged and Abandoned
License Date: 2017-02-24
Spud Date: 2008-12-22
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2009-01-03
Well Total Depth: 4040.00 ft
Configuration: Vertical
Latitude: 41.580000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-01-18 Proposed Formations:CLINTON, Issued Date:1/18/2008, Expired Date:1/17/2009 6:00:00 AM, Drilling unit acres:37.4, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-01-03
Completion Report Received 2009-03-09
APP 2009-08-12 Proposed Formations:CLINTON, Issued Date:8/12/2009, Expired Date:8/12/2010 6:00:00 AM, Drilling unit acres:37.4, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2012-02-08 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 957, OSAIR INC
Change of Owner 2013-12-23 Operator changed from 957, OSAIR INC to 9215, OSAIR INC. OSAIR CANCELED THEN REISTATED WITH A NEW OWNER NUMBER.EAF
APP 2017-02-24 Proposed Formations:CLINTON, Issued Date:2/24/2017, Expired Date:2/24/2019 12:00:00 PM, Drilling unit acres:37.4, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-03-17
Record Last Modified 2017-08-04
Construction Permit Expires 2019-02-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-04 3831 3921 31
3831 3921 31
3831 3921 31

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 308 Mscf 30000 FRAC ALSO USED 208 BBLS WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 GREAT PLAINS EXPLORATION LLC 15375.00 0.00 315
2010 GREAT PLAINS EXPLORATION LLC 646.00 0.00 365
2011 OSAIR INC 826.00 0.00 365
2012 OSAIR INC 467.00 0.00 366
2013 OSAIR INC 261.00 0.00 365
2014 OSAIR INC 462.00 0.00 365
2015 OSAIR INC 321.00 0.00 365
2016 OSAIR INC 20.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 GREAT PLAINS EXPLORATION LLC Brine 480 315
2010 GREAT PLAINS EXPLORATION LLC Brine 0 365
2011 OSAIR INC Brine 400 365
2012 OSAIR INC Brine 320 366
2013 OSAIR INC Brine 160 365
2014 OSAIR INC Brine 120 365
2015 OSAIR INC Brine 0 365
2016 OSAIR INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1148161193 2010-4-21 0:00: PL No Violations
-1570456862 2016-12-20 0:00 UP No Violations
-1775143163 2013-6-6 0:00:0 PW No Violations
-2111338793 2008-12-20 0:00 DD No Violations
-851899872 2016-3-22 0:00: PW No Violations
-995209746 2008-12-22 0:00 DD No Violations
0851899872 2016-03-22 Production Wells No Violations My inspection found the well to be equipped with a pumpjack. The tank battery and well are surrounded by a wooden fence. The man doors on the fences need locks installed on them. The tank battery consists of a 100 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The 100 BBL brine tank has rusted through the side wall of the tank and can not be used. The tank needs to be removed from the location or repaired. The tank load line valves have plugs in them but are not locked. The proper identification is located on the fence of the tank battery. The lease road is in stable condition and is secured with a locked gate.
0995209746 2008-12-22 Drill / Deepen / Reopen No Violations On site for CND job. Operator was setting 35 of conductor. Bedrock was 15 on location. Cement truck on site was frozen up, once valves were thawed out, pump broke down. Cement contractor was going to send another pump truck to site. Waived CND pipe, operator was setting less than one joint, no ground water encountered. CND was landed in bed rock, hole was 12.25. Allowed operator to drill surface hole. Surface to be drilled on fresh water or fresh water mud.
1148161193 2010-04-21 Preliminary Restoration No Violations Board on board fence has been installed around the tank battery and the well head. Lease road gate has been installed. Lease road is stable. NOV for failing to install fence and lease road gate before the well was put into production has been passed. Identification sign is up. E-mailed Tim Reilly, man doors need locks as well as the lease road gate. Vegetation is established. Well spacing is correct.
1230559003 2008-12-23 Drill / Deepen / Reopen No Violations On site for surface cement. First pump truck on site went down. Had to wait on 2nd truck. Surface job went well. Operator is going to shut down till the first of the year. Requested that pits be fenced with safety fence. Operator started fencing pits at the time of surface job. Lease road was stable and in good repair. Permit ID sign was up.
1232552047 2008-12-22 Drill / Deepen / Reopen No Violations Pits have been dug and lined. Pits are in good repair. Lease road is stable. Company called before construction of pits.
1233777498 2009-01-21 Drill / Deepen / Reopen No Violations No one on site at the time of inspection. Operator was flowing well back from the frac job. Flow line had ruptured and was spraying nitrogen gas and natural gas across the frac tank. 2nd frac tank that was on site, was facing north/south, valve was cracked open on it. Tank was leaking starch and fresh water across the site. There were three propane bottles next to the leaking flow line. Called company, Jon and a hand from John D arrived on site. Well was shut off and pipe was replaced. Jon, informed me that the leaking tank just had fresh water and starch in it. Tested water, there were no chlorides in it. Operator replaced flow line. Suggested to the company when flowing back a well, to have someone on site at all times.
1247675842 2009-07-07 Production Wells Violations Noted Lease road is in good repair. Lease road gate is not up. Tank battery is in good repair, fencing has not been installed. Fencing must be installed on HB-278 wells before the well is in production. Well is in production. Debris around well head needs removed, (pit liner trash.) Final grading around edges of well site needs completed. Pits need graded. Attempted to call Tim Reilly twice. NOV faxed to Tim Reilly (440) 205-8680 Well needs shut in, until fencing is up. HB-278 requires fencing around tank battery and wellhead to be in place before the well is put into production. Lease road gate needs installed.
1256757650 2009-10-28 Preliminary Restoration No Violations Well is in production, pump jack was running. Chart was on the separator showing production. Lease road gate has not been installed. Fencing has not been installed. Called Tim Reilly, fencing must be installed immediately. Lease road gate needs installed. Permit to plug has been submitted by company. Explained to Tim, I understand if company is attempting to get what it can from the well before it is plugged, but HB-278 rules must be followed. Chardon Village is HB-278 area.
1265302036 2010-01-14 Production Wells No Violations Well is in production, pump jack was running. Chart is in meter showing production, picture taken of chart and pressure gauges. Well is still in violation of 1501:9-9-05 (2) Prior to placing the well in production, the owner shall install a fence around the wellhead and tank battery/separator and associated production equipment.
1493647432 2017-03-13 Plug / Plug Back No Violations I was on location to witness the plugging of this well. Nicks Well Plugging is the plugging contractor for Osair, Inc. The pumpjack had been removed from the well and the rods and tubing had been removed from the well casing. The bottom plug was to be set through 1 1/2 inch tubing but not enough joints of tubing were onsite. Nicks needed extra joints to set the bottom plug. Nicks will return following day with extra joints of tubing to set plug.
1494249237 2017-03-17 Plug / Plug Back No Violations
1570456862 2016-12-20 UrbanProduction Wells No Violations I conducted an inspection on this well at the request of Bill Stief who is looking to purchase the property and well to convert into a domestic well. The well is equipped with a gas powered motor on the pumpjack. The gas line to the motor had been disconnected and the valves on the wellhead were open. The well was fenced but needed a lock on the man door. Production records were last submitted in 2015 for this well. The tank battery consisted of one 100 BBL production tank, one 100 BBL brine tank and a mechanical separator. The 100 BBL brine tank has holes in it and needs to be removed and replaced. The valves on the separator were open and the valves on the tanks were plugged. The tank battery was diked and fenced with a locked man door. There was proper, legible signage at the tank battery location. The lease access was stable. I contacted Rick Osbourne owner of Osair Inc. about the 100 BBL tank needing removed and replaced and adding a lock to the well man door. Mr. Osbourne informed me that application has been made to obtain a permit to plug the well.
1775143163 2013-06-06 Production Wells No Violations My inspection found the well to be equipped with a pump jack. The tank battery and well are surrounded by a wooden fence. The tank battery consists of a 100 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The dike needs fixed on the north east side. I spoke with Jim from Osair about making the corrections to the dike. The proper identification is located on the tank battery. The lease road is in stable condition.
2111338793 2008-12-20 Drill / Deepen / Reopen No Violations Rig to be moving on location today. Pits are in good repair. Safety fence needs to be installed around pits. ID sign is posted at the entrance to the site.
2138828165 2010-02-02 Production Wells Violations Noted 07/15/2009 a NOV was issued to John D Oil & Gas Company for failing to have well and tank battery fenced. Spoke to Tim Reily from John D, well owner is planning on plugging well. Well needed to be shut in, until plugged or fence was installed. Inspection on 02/02/2010 the well is in production, pump jack is running. Chart is in the meter run. Pictures taken of the pump jack operating, tank battery and chart. Well is in violation of 1509:9-9-05 (2) Prior to placing the well in production, the owner shall install a fence around the wellhead and tank battery/separator and associated production equipment. The correct identification sign needs to be installed on the tank battery. Identification sign shows Great Plains as the operator. Lease road gate needs installed. John D Oil and Gas will be placed on the permit hold list until violations are corrected. Pictures will be sent with this inspection report along with the Urbanized Area permit conditions. Please see #27,#28 and #29 of the Urbanized Area permit conditions. Well is violation of 1501:9-9-05 (2) Prior to placing the well in production, the owner shall install a fence around the wellhead and tank battery/ separator and associated production equipment. Per the Urbanized Area Permit Conditions the well location

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1247675842 US-OH-106594 2009-07-15 General Safety
2138828165 US-OH-121957 2010-02-04 General Safety

For data sources see[9]