34-055-21988

Well Details

Well ID: 34-055-21988
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chardon Township
Operator Name: STINCHCOMB DOROTHY
Well Pad ID:
Farm/Lease Name: STINCHCOMB-BONCHA UNIT
License Status: Domestic Well
License Date: 2007-10-11
Spud Date: 2008-07-13
Spud Drilling Contractor: DIRECT DRILLING
Final Drill Date: 2008-07-22
Well Total Depth: 3886.00 ft
Configuration: Vertical
Latitude: 41.610000
Longitude: -81.200000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-10-11 Proposed Formations:CLINTON, Issued Date:10/11/2007, Expired Date:10/10/2008 6:00:00 AM, Drilling unit acres:22.47, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-07-22 CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM ALLIED OIL FIELD SERVICES LTD TO OWNER ON 11/2/2015 CM.
Construction Permit Expires 2008-10-10 CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM ALLIED OIL FIELD SERVICES LTD TO OWNER ON 11/2/2015 CM.
Completion Report Received 2008-10-30 CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM ALLIED OIL FIELD SERVICES LTD TO OWNER ON 11/2/2015 CM.
Change of Owner 2010-01-25 Operator changed from 3847, HALL & HORNING SERV INC to 8602, ALLIED OIL FIELD SERVICES LTD
Change of Owner 2015-11-02 Operator changed from 8602, ALLIED OIL FIELD SERVICES LTD to 9565, STINCHCOMB DOROTHY
Record Last Modified 2017-02-15 CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM ALLIED OIL FIELD SERVICES LTD TO OWNER ON 11/2/2015 CM.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-12-11 3647 3682 66
3647 3682 66
3647 3682 66

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 HALL & HORNING SERV INC 37.00 0.00 86
2009 HALL & HORNING SERV INC 4235.00 0.00 195
2010 ALLIED OIL FIELD SERVICES LTD 4480.00 0.00 365
2011 ALLIED OIL FIELD SERVICES LTD 3605.00 0.00 365
2012 ALLIED OIL FIELD SERVICES LTD 4075.00 0.00 366
2014 ALLIED OIL FIELD SERVICES LTD 559.00 0.00 365
2015 ALLIED OIL FIELD SERVICES LTD 288.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 HALL & HORNING SERV INC Brine 1155 86
2009 HALL & HORNING SERV INC Brine 0 195
2010 ALLIED OIL FIELD SERVICES LTD Brine 817 365
2011 ALLIED OIL FIELD SERVICES LTD Brine 753 365
2012 ALLIED OIL FIELD SERVICES LTD Brine 804 366
2014 ALLIED OIL FIELD SERVICES LTD Brine 153 365
2015 ALLIED OIL FIELD SERVICES LTD Brine 52 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1203281414 2009-7-22 0:00: PL No Violations
-1644947380 2010-4-21 0:00: PW No Violations
-2028429712 2009-6-12 0:00: PL No Violations
-670343924 2015-4-17 0:00: EX No Violations
-814713396 2009-7-7 0:00:0 PL No Violations
0145650126 2015-08-31 Exempt Well Pre Transfer No Violations My inspection found the company has surveyed the property to confirm that the tank battery is on the landowners property and not on the property of Geauga Parks. The company has removed the separator from the tank battery and the 100 BBL production tank. There is a 50 BBL tank that the flow line is plumbed into for well maintenance. The sales line has been eliminated from landowner access. The well can now only be used for domestic supply for the landowner. The well is currently supplying domestic gas to the landowners residence. No violations found.
0670343924 2015-04-17 Exempt Well Pre Transfer No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus is plumbed up to a pop off valve that leads through a one way valve and back into the flow line. The tank battery consists of a 100 BBL production tank, a 50 BBL brine tank, and a mechanical separator. The domestic supply is currently plumbed off of the sales line attached to the separator. The well has the proper identification. The tank battery is currently on Geauga Park property. The company plans to remove the tank battery and move the domestic equipment from the separator to the wellhead. The company will also be pulling the flow line due to it being on park property. I have been unable on numerous attempts to make contact with the landowner. There is no compliance issues with the well.
0814713396 2009-07-07 Preliminary Restoration No Violations Site has been graded and seeded. Seeding did not take completely on site. Sandy soils are eroding offsite. Site needs repair graded and seeded. Contacted Dan Horning requested that repairs be made once work is complete on the Turner units.
1081698767 2015-06-02 Production Wells No Violations My inspection found no changes since my last inspection. I contacted the well tender for the company and the have Circle M scheduled to remove the tank battery and move the domestic supply from the separator to the wellhead. Once this is completed the domestic transfer can be completed.
1203281414 2009-07-22 Preliminary Restoration No Violations Site has had repair disking and seeding completed on it. Operator has placed silt fence in the center of the affected area to prevent erosion. Site slopes to the north west, drainage tends towards the center of the affected area. Silt fence has been knocked down by drainage and sediment. Contacted operator requested that silt fence be repaired and straw bails be staked in, to slow the velocity of the drainage. Lease road is in good repair.
1265317312 2010-02-02 Preliminary Restoration No Violations Well site is snow covered. Identification sign will need to be updated, well was sold in the past two weeks. Silt fence has been repaired and is in place down slope of the wellhead. Spoke to new owner they are going to complete any repair seeding on location once weather permits. Dike around tank battery is in good repair. Hatch on the small tank in the battery needs replaced, it is currently missing from the tank.
1362034920 2008-07-15 Drill / Deepen / Reopen No Violations Drilling at 137 no violation
145650126 2015-8-31 0:00: EX No Violations
1508731251 2009-08-31 Preliminary Restoration No Violations Repair seeding on location hasnt taken. Sandy soils continue to wash. Operator will need to seed with a fast growing nurse crop to hold soils in place.
1644947380 2010-04-21 Production Wells No Violations PVC drain pipe in dike, plug was placed in pipe at the time of inspection. Identification sign needs replaced and up dated to new owner. Affected area from drilling needs repair seeding., vegetation is sparse and not sufficient to control vegetation. Silt fence is up. Lease road is stable.
1711312527 2008-07-23 Drill / Deepen / Reopen No Violations rigging down to move
1860380440 2008-08-05 Preliminary Restoration No Violations Drilling has been completed. Rig is on site for repairs. Pits are in good repair, fluid has been removed. Lease road is stable.
1926491607 2013-07-24 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open into a pop off valve. The well and tank battery are in good repair. The tank battery consists of a 100 BBL production tank, a 25 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
2028429712 2009-06-12 Preliminary Restoration No Violations On site with Jay Cheslock DMRM supervisor. Site needs repair grading and seeding. Operator has graded site and seeded. Seeding didnt take. Erosion needs repaired.

For data sources see[9]