X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21985

Well Details

Well ID: 34-055-21985
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Russell Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: PIZZINO/KAUCIC
License Status: Producing
License Date: 2007-10-05
Spud Date: 2007-10-25
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2007-10-29
Well Total Depth: 3821.00 ft
Configuration: Vertical
Latitude: 41.500000
Longitude: -81.370000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-10-05 Proposed Formations:CLINTON, Issued Date:10/5/2007, Expired Date:10/4/2008 6:00:00 AM, Drilling unit acres:23.32, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-10-29
Completion Report Received 2008-05-01
Construction Permit Expires 2008-10-04
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-08-26 3619 3667 26
3619 3667 26
3619 3667 26

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 71538 Gal 24000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 CUTTER EXPLORATION INC 8434.00 540.00 365
2009 CUTTER EXPLORATION INC 11766.00 551.00 365
2010 CUTTER EXPLORATION INC 6704.00 374.00 365
2011 CUTTER EXPLORATION INC 5746.00 365.00 0
2012 CUTTER EXPLORATION INC 1517.00 224.00 366
2013 CUTTER EXPLORATION INC 1411.00 360.00 365
2014 CUTTER EXPLORATION INC 1147.00 277.00 365
2015 CUTTER EXPLORATION INC 1518.00 340.00 365
2016 CUTTER EXPLORATION INC 735.00 0.00 365
2017 CUTTER EXPLORATION INC 307.00 1190.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 CUTTER EXPLORATION INC Brine 278 365
2009 CUTTER EXPLORATION INC Brine 138 365
2010 CUTTER EXPLORATION INC Brine 105 365
2011 CUTTER EXPLORATION INC Brine 100
2012 CUTTER EXPLORATION INC Brine 85 366
2013 CUTTER EXPLORATION INC Brine 87 365
2014 CUTTER EXPLORATION INC Brine 46 365
2015 CUTTER EXPLORATION INC Brine 24 365
2016 CUTTER EXPLORATION INC Brine 0 365
2017 CUTTER EXPLORATION INC Brine 20 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-264763682 2014-10-20 0:00 UP No Violations
-484349831 2011-12-13 0:00 UP No Violations
-555529851 2017-2-6 0:00:0 UP No Violations
-837647798 2017-5-30 0:00: UP No Violations
0264763682 2014-10-20 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
0404950407 2019-01-16 UrbanProduction Wells No Violations I conducted an inspection on this well. At the time of this inspection, the well was equipped with a pumping unit and in production. The well was fenced with a locked man door. The tank battery was comprised of two 100 BBL tanks, one 50 BBL tank and a mechanical separator. Valves on the separator were open. The tank valves were equipped with flat plugs and the production tank vent stack was plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. The diked tank battery was fenced and had a locked man door. Legible identification was present at the tank battery and the lease access was stable.
0484349831 2011-12-13 UrbanProduction Wells No Violations Site was in good repair, lease road was stable, fencing was up and man doors were locked. Well has been changed from a plunger lift system to a pumping unit. Identification sign was posted.
0555529851 2017-02-06 UrbanProduction Wells No Violations During this inspection, the well was observed to be equipped with an electric motor on the pumpjack and the valves on the wellhead were open. The well was fenced and locked. The last reported production was submitted in 2015. The tank battery consisted of two 210 BBL production tanks, one 50 BBL steel brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The tank valves were equipped with flat plugs. The vent stack on the production tank was plumbed into a 55 gallon charcoal filter then plumbed up and topped with a spark arrestor. The tank battery was diked and fenced with a locked man door. The signage at the tank battery was no longer legible and needs to be replaced. The lease access was stable. I contacted Mark Turpak from Cutter about replacing the signage at the tank battery.
0837647798 2017-05-30 UrbanProduction Wells No Violations I conducted a reinspection of this well site regarding installation of new signage at the tank battery location. At the time of this inspection, new signage had been installed at the tank battery and no violations were observed.
0915563606 2007-11-05 Drill / Deepen / Reopen No Violations On site per the company pits are to be solidified and closed today. No one on site. Called Lynn, there was a fire at the cement company, will call when they can get product. Pits are in good repair. Safety fence is up around pits. Lease road is stable.
1317836517 2008-12-10 Preliminary Restoration No Violations On site to review gate waiver. Gate waiver is approved at this time. Site has been graded, seeded and vegetation is established. Restoration is passed at this time.
1369836757 2013-05-29 UrbanProduction Wells No Violations My inspection found the well to be equipped with a pump jack. The annulus valve is open. The tank battery and well are in good repair and surrounded by a wood fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL brine tank, and a mechanical separator. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter. The vent stack is then plumbed up and topped with a spark arrestor. The proper identification is located on the tank battery. The lease road is in stable condition.
1391694791 2008-09-22 Production Wells No Violations Well and tank battery are fenced and locked. 8 foot fence with barbed wire. ID signs are up. Well head is fenced into horse pasture. Landscaping is up. Tank battery has one 100BBL tank, 50 BBl tank and a mechanical separator. Road, well and tank battery spacing are per ORC 1509. Vegetation is established.
404950407 2019-1-16 0:00: UP No Violations
915563606 2007-11-5 0:00: DD No Violations

For data sources see[9]

References