Well Details

Well ID: 34-055-21887
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chardon Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: LAKE CHURCH OF CHRIST
License Status: Producing
License Date: 2006-05-19
Spud Date: 2006-07-21
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-07-25
Well Total Depth: 3659.00 ft
Configuration: Vertical
Latitude: 41.630000
Longitude: -81.240000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-05-19 Proposed Formations:CLINTON, Issued Date:5/19/2006, Expired Date:5/19/2007 6:00:00 AM, Drilling unit acres:22, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-07-21
Completed 2006-07-25
Reached Total Depth 2006-07-25
Completion Report Received 2006-10-30
Construction Permit Expires 2007-05-19
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-01-04 3482 3498 20
3482 3498 20
3482 3498 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 468 Bbl 100000 603M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY 9734.00 0.00 144
2007 JOHN D OIL & GAS COMPANY 20050.00 196.00 365
2008 JOHN D OIL & GAS COMPANY 9609.00 71.00 365
2009 JOHN D OIL & GAS COMPANY 8155.00 91.00 365
2010 JOHN D OIL & GAS COMPANY 3530.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 2058.00 18.00 365
2012 JOHN D OIL & GAS COMPANY 1508.00 34.00 366
2013 JOHN D OIL & GAS COMPANY 1504.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 1601.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 1282.00 0.00 365
2016 DAVID OIL COMPANY LLC 274.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY Brine 230 144
2007 JOHN D OIL & GAS COMPANY Brine 720 365
2008 JOHN D OIL & GAS COMPANY Brine 400 365
2009 JOHN D OIL & GAS COMPANY Brine 240 365
2010 JOHN D OIL & GAS COMPANY Brine 320 365
2011 JOHN D OIL & GAS COMPANY Brine 80 365
2012 JOHN D OIL & GAS COMPANY Brine 80 366
2013 JOHN D OIL & GAS COMPANY Brine 0 365
2014 JOHN D OIL & GAS COMPANY Brine 0 365
2015 JOHN D OIL & GAS COMPANY Brine 0 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1515045482 2013-7-23 0:00: PW No Violations
-615652381 2008-7-15 0:00: PW No Violations
0111893105 2013-08-07 Production Wells No Violations I am on location due to some information we received about a leaking wellhead. This well is in good repair and there is not a leak to report. No violations found. Nothing has changed since my last inspection.
0245726542 2016-03-22 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is plumbed up and into a pressure relief valve. The tank battery consists of a 210 BBL production tank and a 100 BBL brine tank. The dike around the tank battery needs to be rebuilt. The heated separator is outside of the tank battery with the proper spacing. The load line valves have plugs installed in them and are locked. The proper identification sign is on the tank battery. There is an oil stain with old absorbent pads next to the wellhead that needs to be cleaned up. The lease road is in stable condition. I have contacted the company about the issues.
0615652381 2008-07-15 Production Wells No Violations request from Scoot Kell to check back side LEL reading 40% ,and H2S 0 PPM ,
0726168945 2011-04-05 Production Wells No Violations Well site is in good repair. Operator has installed a pop-off on the annulus.
1067053294 2010-09-28 Production Wells No Violations Well site is in good repair. Spacing is correct. Identification sign is posted. Rabbit well has 400psi on the 4.5 inch and 300psi on the tubing. Lease road is stable and in good repair. Small amount of bubbling coming from the packing around the 4.5 inch casing and annulus. Called Tim at John D and requested locks on load lines and the annulus to be plumbed above ground and a pop-off put on, to vent annulus gas. Spoke to Tim regarding work on the well, well tender has been on location as the norm. Appears a valve has been replaced on the separator. Pictures taken of location during inspection. No H2S or LEL levels detected with gas meter around wellhead, tank battery or separator. Called Jon Magnus 09/30/2010, no work complete on Monday by his people. Asked Jon to build up dike around the tank battery.
111893105 2013-8-7 0:00:0 PW No Violations
1156771432 2006-07-24 Drill / Deepen / Reopen No Violations Received a gas odor complaint at 11034 Girdled road of concord township. Phone call from Concord Fire Department had responded to the address 11034 Girdled rd of a strong odor in their home and their child was taken to hospital and examined blood test done and he was released , was advised to follow up with family doctor. Phone calls to company talked with Greg Osborn. The rig hit gas at approx 3184 at 1:00Am Monday and by 2:00 Am Switched to fluid drilling. Greg said the concord fire department had responded to site because of gas odor complaint. Checked the area residence along auburn road and girdled rd found no reading of gas in or around houses involved. He said he is on his way to address 11034 Girdled , with ventilating fans Follow up phone conversation Greg stated that the fans were running by noon.

On site inspection found rig on fluid slight gas odor present in air CHECKED FOR GAS NO READING. Pits lined drilling at 3400 there TD is 3700 Phone call to fire department Concord TWP they were covering for Chardon fire Department, They had checked for gas in and around homes along Auburn rd and girdled rd at time of incident and also Monday morning no gas was detected.

1179245975 2007-05-15 Preliminary Restoration No Violations Well is in production. Site has been graded and seeded. Vegetation is established. Spoke to church officials, they are happy with the grading. Topsoil stockpile to the west was on site before drilling. Church wants grading the way it is. One 110 BBL tank on site, one 210 tank on site, heat treat separator on site. Spacing is good. Rabbit well.
1236352566 2009-03-06 Production Wells No Violations Well is in good repair. Small amount of bubbling around the 4.5 inch packing.
1515045482 2013-07-23 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is plumbed up into a pop off valve. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank and a 100 BBL brine tank. The heat treated separator has the proper spacing from the tank battery. The proper identification is located on the tank battery. The lease road is in stable condition.
1998177571 2006-07-20 Drill / Deepen / Reopen No Violations making location
245726542 2016-3-22 0:00: PW No Violations
726168945 2011-4-5 0:00:0 PW No Violations

For data sources see[9]