34-055-21668

Well Details

Well ID: 34-055-21668
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: J WELL SERVICE INC
Well Pad ID:
Farm/Lease Name: RUSSELL UNIT
License Status: Producing
License Date: 1990-12-05
Spud Date: 1990-12-27
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1991-01-01
Well Total Depth: 3797.00 ft
Configuration: Vertical
Latitude: 41.510000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1990-12-05 2037 CEDAR VALLEY ENERGY INC GeoDate 12/5/90
Oil and Gas 1990-12-05 Issued Date 12/5/90 Expired Date 12/5/91 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03797 Proposed Drill Depth 03797
Original Spud 1990-12-27
Completed 1991-01-01
Reached Total Depth 1991-01-01
Completion Report Received 1991-02-22
Construction Permit Expires 1991-12-05
Change of Owner 2016-12-29 Operator changed from 2037, CEDAR VALLEY ENERGY INC to 8738, J WELL SERVICE INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3640 3734 0
3640 3734 0
2006-09-11 3672 3699 16
3672 3699 16
3640 3734 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 71550 Gal 450000 FRAC:WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1991 CEDAR VALLEY ENERGY INC 8115.00 137.00 161
1992 CEDAR VALLEY ENERGY INC 19781.00 196.00 365
1993 CEDAR VALLEY ENERGY INC 12752.00 132.00 365
1994 CEDAR VALLEY ENERGY INC 11606.00 158.00 365
1995 CEDAR VALLEY ENERGY INC 10902.00 195.00 365
1996 CEDAR VALLEY ENERGY INC 8946.00 189.00 365
1997 CEDAR VALLEY ENERGY INC 8663.00 117.00 365
1998 CEDAR VALLEY ENERGY INC 7090.00 136.00 365
1999 CEDAR VALLEY ENERGY INC 6682.00 103.00 365
2000 CEDAR VALLEY ENERGY INC 6259.00 191.00 365
2001 CEDAR VALLEY ENERGY INC 6105.00 177.00 365
2002 CEDAR VALLEY ENERGY INC 5733.00 102.00 365
2003 CEDAR VALLEY ENERGY INC 6016.00 126.00 365
2004 CEDAR VALLEY ENERGY INC 5787.00 55.00 365
2005 CEDAR VALLEY ENERGY INC 3940.00 118.00 365
2006 CEDAR VALLEY ENERGY INC 3065.00 142.00 365
2007 CEDAR VALLEY ENERGY INC 3228.00 62.00 365
2008 CEDAR VALLEY ENERGY INC 3435.00 130.00 365
2009 CEDAR VALLEY ENERGY INC 3843.00 70.00 365
2010 CEDAR VALLEY ENERGY INC 4106.00 99.00 365
2011 CEDAR VALLEY ENERGY INC 4622.00 110.00 365
2012 CEDAR VALLEY ENERGY INC 4434.00 90.00 366
2013 CEDAR VALLEY ENERGY INC 3527.00 44.00 365
2014 CEDAR VALLEY ENERGY INC 3641.00 78.00 365
2015 CEDAR VALLEY ENERGY INC 3107.00 76.00 365
2016 CEDAR VALLEY ENERGY INC 3387.00 58.00 365
2017 CEDAR VALLEY ENERGY INC 733.00 0.00 365
2018 J WELL SERVICE INC 3392.00 48.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1991 CEDAR VALLEY ENERGY INC Brine 157 161
1992 CEDAR VALLEY ENERGY INC Brine 113 365
1993 CEDAR VALLEY ENERGY INC Brine 55 365
1994 CEDAR VALLEY ENERGY INC Brine 80 365
1995 CEDAR VALLEY ENERGY INC Brine 69 365
1996 CEDAR VALLEY ENERGY INC Brine 77 365
1997 CEDAR VALLEY ENERGY INC Brine 40 365
1998 CEDAR VALLEY ENERGY INC Brine 0 365
1999 CEDAR VALLEY ENERGY INC Brine 25 365
2000 CEDAR VALLEY ENERGY INC Brine 20 365
2001 CEDAR VALLEY ENERGY INC Brine 30 365
2002 CEDAR VALLEY ENERGY INC Brine 0 365
2003 CEDAR VALLEY ENERGY INC Brine 0 365
2004 CEDAR VALLEY ENERGY INC Brine 0 365
2005 CEDAR VALLEY ENERGY INC Brine 20 365
2006 CEDAR VALLEY ENERGY INC Brine 3 365
2007 CEDAR VALLEY ENERGY INC Brine 25 365
2008 CEDAR VALLEY ENERGY INC Brine 0 365
2009 CEDAR VALLEY ENERGY INC Brine 22 365
2010 CEDAR VALLEY ENERGY INC Brine 36 365
2011 CEDAR VALLEY ENERGY INC Brine 27 365
2012 CEDAR VALLEY ENERGY INC Brine 20 366
2013 CEDAR VALLEY ENERGY INC Brine 12 365
2014 CEDAR VALLEY ENERGY INC Brine 0 365
2015 CEDAR VALLEY ENERGY INC Brine 0 365
2016 CEDAR VALLEY ENERGY INC Brine 71 365
2017 CEDAR VALLEY ENERGY INC Brine 0 365
2018 J WELL SERVICE INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-280405468 2017-5-9 0:00:0 UP No Violations
-659213585 2018-2-12 0:00: UP No Violations
0000008359 Preliminary Restoration No Violations PASSED Y WITNESSED 6/17/91 INSPECTOR KOHL, ERNEST DATE 06/1719/91 DATA FROM OLD VAX INFO
0280405468 2017-05-09 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. There was a domestic line plumbed off of the 4.5 inch casing with two regulators, a drip bottle and meter. Production records for this well were current. The well was fenced. The tank battery consisted of two 100 BBL production tanks, one 35 BBL poly brine and two mechanical separators. The tank battery is shared with well 2-1695. Valves on the separators were open and both charts were dated 5/1/17 and showed production. The tank valves were equipped with flat plugs. The tank battery was diked. Proper, legible signage was located tank battery but needed to be installed at the well. The lease access was stable. I contacted Jim Adams from J. Well Service about installing signage at the well location.
0659213585 2018-02-12 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. There was a domestic line plumbed off of the 4.5 inch casing with two regulators, a drip bottle and meter. Production records for this well were current. The well was fenced. The tank battery consisted of two 100 BBL production tanks, one 35 BBL poly brine and two mechanical separators. The tank battery is shared with well 2-1695. Valves on the separators were open. The tank battery was diked. Proper, legible signage was located tank battery and has also been installed at the well. The lease access was stable. No violations observed.
1387560589 2013-06-14 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The chain link fence around the wellhead needs repaired. Contacted Tim Cosmo about the repair. The tank battery consists of two 100 BBL production tanks, two 35 BBL brine tanks, and two mechanical separators. The proper identification is located on the wellhead and the tank battery. The lease road is in stable condition. The tank battery is being shared by permit number 2-1695.
8359 PL No Violations

For data sources see[9]

References