X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-21516

Well Details

Well ID: 34-055-21516
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Hambden Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: LILLY
License Status: Producing
License Date: 2007-04-27
Spud Date: 2007-11-08
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2007-11-16
Well Total Depth: 3840.00 ft
Configuration: Vertical
Latitude: 41.640000
Longitude: -81.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1987-12-30 28 CGAS EXPLORATION,INC GeoDate 12/30/87
Oil and Gas 1987-12-30 Issued Date 12/30/87 Expired Date 12/29/88 Acres 0020000 Tool Type CRAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
APP 2007-04-27 Proposed Formations:CLINTON, Issued Date:4/27/2007, Expired Date:4/26/2008 6:00:00 AM, Drilling unit acres:22, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-11-16
Reached Total Depth 2007-11-16
Completion Report Received 2008-01-04
Construction Permit Expires 2008-04-26
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-01-22 3640 3662 16
3640 3662 16
3640 3662 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 500 Bbl 100000 FRAC ALSO INCLUDED 657 MSCF OF N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 EXCO - NORTH COAST ENERGY INC 4.00 0.00 365
2008 JOHN D OIL & GAS COMPANY 2523.00 103.00 309
2009 JOHN D OIL & GAS COMPANY 2457.00 26.00 365
2010 JOHN D OIL & GAS COMPANY 2128.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 1860.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 1973.00 0.00 366
2013 JOHN D OIL & GAS COMPANY 2099.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 2092.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 177.00 0.00 365
2016 DAVID OIL COMPANY LLC 0.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 EXCO - NORTH COAST ENERGY INC Brine 0 365
2008 JOHN D OIL & GAS COMPANY Brine 1020 309
2009 JOHN D OIL & GAS COMPANY Brine 210 365
2010 JOHN D OIL & GAS COMPANY Brine 300 365
2011 JOHN D OIL & GAS COMPANY Brine 240 365
2012 JOHN D OIL & GAS COMPANY Brine 120 366
2013 JOHN D OIL & GAS COMPANY Brine 102 365
2014 JOHN D OIL & GAS COMPANY Brine 210 365
2015 JOHN D OIL & GAS COMPANY Brine 0 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-181772332 2013-7-25 0:00: PW No Violations
-1861508667 2009-3-6 0:00:0 PL No Violations
-1963608662 2018-5-30 0:00: PW No Violations
-501711939 2016-3-22 0:00: PW No Violations
-603631670 2020-1-9 0:00:0 PW No Violations 1.30
-911023819 2019-1-3 0:00:0 PW No Violations 0.20
-973854132 2018-10-17 0:00 PW No Violations
0181772332 2013-07-25 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is closed. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank. The heat treated separator has the proper spacing from the tank battery. The proper identification is located on the tank battery. The lease road is in stable condition.
0464298638 2017-10-17 Production Wells No Violations I conducted an inspection on this well in regards to complaint #5723. Landowner Dan Lilly was concerned about the well production status. At the time of this inspection, I met with landowner Dan Lilly on site and the well was equipped with a plunger lift assembly and the annulus and flow line valves were closed. Production records for this well were submitted in 2015 with 177 mcf for gas and in 2016 as zero. The tank battery consisted of one 210 BBL production tank and a heater treater separator. Valves on the separator were open. The separator was located outside of the diked tank battery. There was a dike present around the 210 BBL production tank. Signage was present at the tank battery but needed to be updated to reflect current owner information. The lease access was stable. I contacted the David Oil Company, LLC at 440-951-1111 and spoke with a Jenny Corrao. She informed me that the field superintendent would be notified about updating the signage.
0501711939 2016-03-22 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The valves in the wellhead are in the closed position. The annulus valve is closed. The well and the tank battery are in good repair. The tank battery consists of a 210 BBL production tank. The load line valves have plugs installed in them but are not locked. The heated separator is outside of the tank battery with the proper spacing. The flow line valve on the separator is in the closed position. The proper identification sign is installed on the tank battery. The lease road is in stable condition.
0911023819 2019-01-03 Production Wells No Violations I conducted a compliance notice follow-up for compliance notice 973854132, regarding updating the identification with new owner information. At the time of this inspection, the identification had not been updated to reflect current owner information. I contacted David Oil Company, LLC and left a message with well tender John Magnuson at 440-667-9414, regarding the updating of the owner/operator information on the identification.
0973854132 2018-10-17 Production Wells Violations Noted I conducted an inspection on this well. The well was equipped with a plunger lift assembly and the annulus and flow line valves were open. Production submitted in 2016 was zero and 2017 records were not submitted at the time of this inspection. The tank battery consisted of one 210 BBL tank and a mechanical separator. Valves on the separator were open and there was a chart in the separator, dated 10/16/18 that showed production. The tank battery was diked. The identification at the tank battery needed updated current owner information. The lease access was stable. The owner must place ID in compliance with OAC 1501-9:9-05(A)(10) by no later than 10/24/18 or be subject to additional enforcement. Contact Inspector Shannon Mullins at 330-413-5921.
1861508667 2009-03-06 Preliminary Restoration No Violations Site has been graded and seeded. Vegetation is established. Well is a rabbit well. Well needs ID sign, well is produced into a mutual tank battery with permit 1937. Tank battery needs ID sign for permit 1516 posted on it.
1963608662 2018-05-30 Production Wells No Violations I conducted an inspection on this well as a follow-up from complaint #5723 regarding well production. The well was equipped with a plunger lift assembly and the annulus and flow line valves were open. Production submitted in 2016 was zero and 2017 records are not available at the time of this inspection. The tank battery consisted of one 210 BBL tank and a mechanical separator. Valves on the separator were open and there was a chart in the separator, dated 5/30/18. The tank battery was diked. The signage located at the tank battery, still has not been updated to reflect the new name and company information. The lease access was stable. I contacted David Oil Company, LLC about updating the signage.
464298638 2017-10-17 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0973854132 US-OH-131175 2018-11-16 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]

References