34-055-21352

Well Details

Well ID: 34-055-21352
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Mantua Township
Operator Name: CEDAR VALLEY ENERGY INC
Well Pad ID:
Farm/Lease Name: SPAETH HELEN
License Status: Producing
License Date: 1985-12-19
Spud Date: 1986-01-17
Spud Drilling Contractor: NANCY DRLG
Final Drill Date: 1986-01-23
Well Total Depth: 4118.00 ft
Configuration: Vertical
Latitude: 41.340000
Longitude: -81.280000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1985-12-19 1553 NORTH AMERICAN PROD CO GeoDate 12/19/85
Oil and Gas 1985-12-19 Issued Date 12/19/85 Expired Date 12/19/86 Acres 0040000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 04118 Proposed Drill Depth 04118
Original Spud 1986-01-17
Completed 1986-01-23
Reached Total Depth 1986-01-23
Completion Report Received 1986-02-18
Construction Permit Expires 1986-12-19
Change of Owner 2006-05-15 Operator changed from 1553, NORTH AMERICAN PROD CO to 2037, CEDAR VALLEY ENERGY INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3941 3995 38
3941 3995 38
3941 3995 38

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 80500 Gal 50000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 NORTH AMERICAN PROD CO 24832.00 3439.00 245
1987 NORTH AMERICAN PROD CO 12372.00 3352.00 330
1988 NORTH AMERICAN PROD CO 12913.00 2639.00 324
1989 NORTH AMERICAN PROD CO 10084.00 1726.00 305
1990 NORTH AMERICAN PROD CO 8250.00 1341.00 346
1991 NORTH AMERICAN PROD CO 6307.00 991.00 334
1992 NORTH AMERICAN PROD CO 6274.00 486.00 365
1993 NORTH AMERICAN PROD CO 5241.00 523.00 340
1994 NORTH AMERICAN PROD CO 5599.00 567.00 339
1995 NORTH AMERICAN PROD CO 4925.00 568.00 309
1996 NORTH AMERICAN PROD CO 3543.00 393.00 331
1997 NORTH AMERICAN PROD CO 4308.00 492.00 365
1998 NORTH AMERICAN PROD CO 2939.00 340.00 365
2000 CEDAR VALLEY ENERGY INC 2685.00 365.00 365
2001 CEDAR VALLEY ENERGY INC 2211.00 329.00 365
2002 CEDAR VALLEY ENERGY INC 2296.00 236.00 365
2003 CEDAR VALLEY ENERGY INC 1805.00 333.00 364
2004 CEDAR VALLEY ENERGY INC 1863.00 272.00 365
2005 CEDAR VALLEY ENERGY INC 1923.00 142.00 365
2006 CEDAR VALLEY ENERGY INC 1513.00 94.00 365
2007 CEDAR VALLEY ENERGY INC 1827.00 259.00 365
2008 CEDAR VALLEY ENERGY INC 1909.00 193.00 365
2009 CEDAR VALLEY ENERGY INC 1910.00 170.00 365
2010 CEDAR VALLEY ENERGY INC 1763.00 156.00 365
2011 CEDAR VALLEY ENERGY INC 1889.00 201.00 365
2012 CEDAR VALLEY ENERGY INC 1706.00 255.00 366
2013 CEDAR VALLEY ENERGY INC 2287.00 119.00 365
2014 CEDAR VALLEY ENERGY INC 1906.00 198.00 365
2015 CEDAR VALLEY ENERGY INC 1986.00 179.00 365
2016 CEDAR VALLEY ENERGY INC 2368.00 200.00 365
2017 CEDAR VALLEY ENERGY INC 2349.00 158.00 365
2018 CEDAR VALLEY ENERGY INC 2145.00 154.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 NORTH AMERICAN PROD CO Brine 620 245
1987 NORTH AMERICAN PROD CO Brine 2757 330
1988 NORTH AMERICAN PROD CO Brine 312 324
1989 NORTH AMERICAN PROD CO Brine 110 305
1990 NORTH AMERICAN PROD CO Brine 56 346
1991 NORTH AMERICAN PROD CO Brine 37 334
1992 NORTH AMERICAN PROD CO Brine 67 365
1993 NORTH AMERICAN PROD CO Brine 29 340
1994 NORTH AMERICAN PROD CO Brine 44 339
1995 NORTH AMERICAN PROD CO Brine 96 309
1996 NORTH AMERICAN PROD CO Brine 102 331
1997 NORTH AMERICAN PROD CO Brine 103 365
1998 NORTH AMERICAN PROD CO Brine 84 365
2000 CEDAR VALLEY ENERGY INC Brine 39 365
2001 CEDAR VALLEY ENERGY INC Brine 42 365
2002 CEDAR VALLEY ENERGY INC Brine 26 365
2003 CEDAR VALLEY ENERGY INC Brine 88 364
2004 CEDAR VALLEY ENERGY INC Brine 53 365
2005 CEDAR VALLEY ENERGY INC Brine 23 365
2006 CEDAR VALLEY ENERGY INC Brine 21 365
2007 CEDAR VALLEY ENERGY INC Brine 18 365
2008 CEDAR VALLEY ENERGY INC Brine 36 365
2009 CEDAR VALLEY ENERGY INC Brine 33 365
2010 CEDAR VALLEY ENERGY INC Brine 61 365
2011 CEDAR VALLEY ENERGY INC Brine 53 365
2012 CEDAR VALLEY ENERGY INC Brine 57 366
2013 CEDAR VALLEY ENERGY INC Brine 50 365
2014 CEDAR VALLEY ENERGY INC Brine 72 365
2015 CEDAR VALLEY ENERGY INC Brine 24 365
2016 CEDAR VALLEY ENERGY INC Brine 55 365
2017 CEDAR VALLEY ENERGY INC Brine 34 365
2018 CEDAR VALLEY ENERGY INC Brine 31 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1689458368 2018-5-1 0:00:0 UP No Violations
-1811678117 2014-10-14 0:00 UP No Violations
0767849647 2015-04-22 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
0984940183 2010-06-04 Production Wells No Violations Well is a pump jack well. Well needs an identification sign, contacted Mr. Cosma from Cedar Valley in regards to signs. Well is in good repair. Lease road is stable. Man door on tank battery was locked. Lease road gate was locked. Identification signs were up for all three wells that are produced into the tank battery.
1445956023 2015-10-26 UrbanProduction Wells No Violations My inspection found the well to be equipped with a pumpjack. The stuffing box is leaking and the seals need repaired. The tank battery is surrounded by a locked chain link fence. The tank battery consists of a 210 BBL production tank, a 100 BBL brine tank, and two mechanical separators. There are multiple 2 line fittings inside the tank battery that are showing signs of leaking that need repaired. The proper identification is located on the wellhead and the tank battery. The lease road is in stable condition. The tank battery is being shared with permit numbers 2-1413 and 2-1417. I contacted Bob McGarry the well tender for Cedar Valley about the repairs.
1689458368 2018-05-01 UrbanProduction Wells No Violations At the time of my inspection the well was equipped with a pumpjack. Valves on the well were open and production records for this well, were current. The tank battery consisted of one 210 BBL production tank, one 100 BBL brine tank, and two mechanical separators. The tank battery was diked and fenced with a locked man door. The proper identification was located at the well and tank battery. The tank battery was shared with wells 2-1413 and 2-1417. The lease access was stable. No violations observed.
1811678117 2014-10-14 UrbanProduction Wells No Violations My inspection found the well to be equipped with a pump jack. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of a 210 BBL production tank, a 100 BBL production tank, and two mechanical separators. The proper identification is located on the tank battery. The lease road is in stable condition. The tank battery is being shared with permit numbers 2-1413 and 2-1417.
2071348211 2013-03-21 Production Wells No Violations The well is equipped with a pump jack. The well and tank battery are in good repair. The tank battery is surrounded by a chain link fence. The tank battery consists of a 210 BBL production tank, a 100 BBL production tank, and two mechanical separators. The proper identification is located on the tank battery. The lease road is in stable condition. The tank battery is being shared with permit numbers 2-1413 and 2-1417.
767849647 2015-4-22 0:00: UP No Violations
984940183 2010-6-4 0:00:0 PW No Violations

For data sources see[9]