34-055-20950

Well Details

Well ID: 34-055-20950
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Thompson Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: DERUS A
License Status: Producing
License Date: 1984-08-31
Spud Date: 1984-10-24
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1984-10-28
Well Total Depth: 3659.00 ft
Configuration: Vertical
Latitude: 41.700000
Longitude: -81.080000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-08-31 Issued Date 8/31/84 Expired Date 2/27/85 Acres 0130640 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03635 Proposed Drill Depth 03635
Original Spud 1984-10-24 I.P. OIL & GAS EST.
Completed 1984-10-28 I.P. OIL & GAS EST.
Reached Total Depth 1984-10-28 I.P. OIL & GAS EST.
Completion Report Received 1984-11-19 I.P. OIL & GAS EST.
CO 1984-12-28 1530 CNG PRODUCING COMPANY GeoDate 8/31/84
Construction Permit Expires 1985-02-27 I.P. OIL & GAS EST.
CO 1991-08-19 28 CGAS EXPLORATION,INC GeoDate 8/31/84
Change of Owner 2007-04-27 Operator changed from 28, CGAS EXPLORATION to 7578, ENERVEST OPERATING LLC
Last Compliance Report 2013-10-10 I.P. OIL & GAS EST.
Change of Owner 2017-05-01 Operator changed from 7578, ENERVEST OPERATING LLC, to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-08-18 I.P. OIL & GAS EST.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3390 3485 0
3390 3485 0
2006-09-11 3402 3451 27
3402 3451 27
3390 3485 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 250 Gal 0
H2O 0 50000 Gal 60000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 CNG PRODUCING COMPANY 26923.00 988.00 365
1986 CNG PRODUCING COMPANY 26893.00 1093.00 365
1988 CNG PRODUCING COMPANY 10560.00 114.00 365
1989 CNG PRODUCING COMPANY 7313.00 183.00 365
1990 CNG PRODUCING COMPANY 6851.00 141.00 365
1991 CGAS EXPLORATION 2547.00 130.00 365
1992 CGAS EXPLORATION 4049.00 96.00 366
1993 CGAS EXPLORATION 3479.00 97.00 366
1994 CGAS EXPLORATION 3478.00 96.00 365
1995 CGAS EXPLORATION 2847.00 46.00 365
1996 CGAS EXPLORATION 2894.00 89.00 365
1997 CGAS EXPLORATION 3224.00 46.00 365
1998 CGAS EXPLORATION 2815.00 48.00 365
1999 CGAS EXPLORATION 2507.00 36.00 365
2000 CGAS EXPLORATION 2382.00 145.00 365
2001 CGAS EXPLORATION 2529.00 81.00 365
2002 CGAS EXPLORATION 2772.00 0.00 365
2003 CGAS EXPLORATION 1666.00 69.00 365
2004 CGAS EXPLORATION 2212.00 57.00 365
2005 CGAS EXPLORATION 1122.00 0.00 365
2006 CGAS EXPLORATION 1232.00 65.00 365
2007 ENERVEST OPERATING LLC 1036.00 0.00 365
2008 ENERVEST OPERATING LLC 939.00 42.00 365
2009 ENERVEST OPERATING LLC 745.00 51.00 365
2010 ENERVEST OPERATING LLC 1211.00 43.00 365
2011 ENERVEST OPERATING LLC 1517.00 0.00 0
2012 ENERVEST OPERATING LLC 1292.00 51.00 366
2013 ENERVEST OPERATING LLC 1210.00 0.00 365
2014 ENERVEST OPERATING LLC 1254.00 60.00 365
2015 ENERVEST OPERATING LLC 1463.00 56.00 365
2016 ENERVEST OPERATING LLC 1528.00 50.00 366
2017 M & R INVESTMENTS OHIO LLC 1958.00 0.00 365
2018 M & R INVESTMENTS OHIO LLC 1492.00 39.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 CNG PRODUCING COMPANY Brine 1594 365
1986 CNG PRODUCING COMPANY Brine 3117 365
1988 CNG PRODUCING COMPANY Brine 205 365
1989 CNG PRODUCING COMPANY Brine 406 365
1990 CNG PRODUCING COMPANY Brine 290 365
1991 CGAS EXPLORATION Brine 244 365
1992 CGAS EXPLORATION Brine 245 366
1993 CGAS EXPLORATION Brine 233 366
1994 CGAS EXPLORATION Brine 308 365
1995 CGAS EXPLORATION Brine 261 365
1996 CGAS EXPLORATION Brine 229 365
1997 CGAS EXPLORATION Brine 137 365
1998 CGAS EXPLORATION Brine 243 365
1999 CGAS EXPLORATION Brine 242 365
2000 CGAS EXPLORATION Brine 215 365
2001 CGAS EXPLORATION Brine 196 365
2002 CGAS EXPLORATION Brine 93 365
2003 CGAS EXPLORATION Brine 160 365
2004 CGAS EXPLORATION Brine 67 365
2005 CGAS EXPLORATION Brine 88 365
2006 CGAS EXPLORATION Brine 120 365
2007 ENERVEST OPERATING LLC Brine 111 365
2008 ENERVEST OPERATING LLC Brine 163 365
2009 ENERVEST OPERATING LLC Brine 98 365
2010 ENERVEST OPERATING LLC Brine 143 365
2011 ENERVEST OPERATING LLC Brine 96
2012 ENERVEST OPERATING LLC Brine 35 366
2013 ENERVEST OPERATING LLC Brine 54 365
2014 ENERVEST OPERATING LLC Brine 0 365
2015 ENERVEST OPERATING LLC Brine 0 365
2016 ENERVEST OPERATING LLC Brine 0 366
2017 ENERVEST OPERATING LLC Brine 0 193
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1059969245 2007-8-2 0:00:0 PW No Violations
-1289500397 2013-9-10 0:00: PW No Violations
-287593708 2012-9-28 0:00: AD No Violations 20.00
-440300140 2017-6-26 0:00: AD No Violations
-919020795 2017-6-26 0:00: PW No Violations
0287593708 2012-09-28 Annular Disposal No Violations The wellhead is fitted with a mechanical plunger lift. There is a domestic meter at the wellhead. The valve to the 8.75-inch casing is buried. Exposure of this connection would be necessary to confirm that annular disposal is not occurring. The tank battery (TB) is located 200 feet to the southeast. The TB is comprised of one, 210 barrel (BBL) production tank, one, 50 BBL brine tank, and a mechanical separator unit. There is no chart recorder. A chain link fence encloses both the wellhead and the TB. There are no locks on the gates, and the fence at the TB is partially missing. There is a low dike around the TB. I did not observe any evidence of leakage or venting gas. There is an ID sign at the TB, but it is in poor condition. There is no ID at the wellhead.
0440300140 2017-06-26 Annular Disposal No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and no annular disposal was present.
0463876403 2013-07-02 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The well has a house line plumbed into the casing. The wellhead is surrounded by a chain link fence. The tank battery is in good repair. The chain link fence around it has had a side removed and needs to be repaired. The tank battery consists of a 100 BBL production tank, a 25 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
0919020795 2017-06-26 Production Wells No Violations During this inspection, the well was observed to be equipped with a plun ger lift assembly and the valves on the wellhead were open. There was a domestic line plumbed off of the 4.5 inch casing with a meter, drip bottle and regulator. Valves on the domestic line were open. There was an audible and visible gas leak around the 4.5 inch casing. The well was fenced and needed some vegetative maintenance. The tank battery consisted of one 100 BBL production tank, one 25 BBL poly brine tank and a mechanical separator. Valves on the separator were open but no chart box was present. Tank valves were equipped with flat plugs. The tank battery was diked and fenced. Legible signage was located at the tank battery and the lease access was stable. I contacted John Raber from M&R Investments about the leak at the wellhead and conducting vegetative maintenance. No annular disposal was present at the time of this inspection.
1059969245 2007-08-02 Production Wells No Violations Well head is fenced no leaks. Tank battery one 100BBL tank and one 210 that is no longer in use. 210 is rusted out. 3 sections of the tank battery fence are missing. Tank battery is signed. Dike is in good repair.
1190126870 2007-09-18 Annular Disposal No Violations Operator has trimmed around the tank battery. Well head is fenced. Tank battery fence is in poor condition south end of the fence for the tank battery is down. One 110 BBL tank and a mechanical separator on site.
1289500397 2013-09-10 Production Wells No Violations My inspection today found no changes since my last. The fence around the tank battery still needs repaired. I will contact Larry Lauer from Enervest about the issue.
1685334278 2020-4-15 0:00: PW No Violations 1.00
1806414539 2018-11-05 Production Wells Violations Noted I conducted an inspection on this well. The well was equipped with a plunger lift assembly and in production. The well was fenced. The tank battery was comprised of one 100 BBL tank, one 25 BBL tank and a mechanical separator. The 100 BBL tank bottom was leaking and oil staining could be observed at the base of the tank. The diked tank battery was fenced with legible signage. The lease access was stable.

M&R Investments needs to: 1) Empty and remove the leaking tank 2) Clean out the tank prior to removal 3) Remove any impacted soil/stone within the tank battery and dispose of the material at a proper facility

463876403 2013-7-2 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1806414539 US-OH-118046 2018-11-06 9-9-05(A)8 Equipment pressure rated below operating pressure

For data sources see[9]

References