34-055-20726

Well Details

Well ID: 34-055-20726
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Montville Township
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: OMIECINSKI
License Status: Producing
License Date: 1984-01-23
Spud Date: 1984-02-12
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1984-02-16
Well Total Depth: 3995.00 ft
Configuration: Vertical
Latitude: 41.600000
Longitude: -81.050000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-01-23 Issued Date 1/23/84 Expired Date 7/21/84 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03995 Proposed Drill Depth 03995
Original Spud 1984-02-12 I.P. OIL & GAS EST.
Completed 1984-02-16 I.P. OIL & GAS EST.
Reached Total Depth 1984-02-16 I.P. OIL & GAS EST.
Completion Report Received 1984-04-12 I.P. OIL & GAS EST.
CO 1984-05-01 1530 CNG PRODUCING COMPANY GeoDate 1/23/84
Construction Permit Expires 1984-07-21 I.P. OIL & GAS EST.
CO 1991-08-19 28 CGAS EXPLORATION,INC GeoDate 1/23/84
Change of Owner 1999-09-07 Operator changed from 28, CGAS EXPLORATION to 6295, KNOX ENERGY INC.
Change of Owner 2003-01-23 Operator changed from 6295, KNOX ENERGY INC. to 7276, SELECT ENERGY INVESTMENTS INC
Last Compliance Report 2013-10-10 I.P. OIL & GAS EST.
Record Last Modified 2017-08-18 I.P. OIL & GAS EST.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3799 3860 0
3799 3860 0
2006-09-11 3801 3856 21
3801 3856 21
3799 3860 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 500 Gal 0
H2O 0 76670 Gal 44100 FRAC;H2O,SAND,ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 CNG PRODUCING COMPANY 7485.00 565.00 365
1986 CNG PRODUCING COMPANY 4278.00 185.00 365
1988 CNG PRODUCING COMPANY 1980.00 253.00 365
1989 CNG PRODUCING COMPANY 2917.00 94.00 365
1990 CNG PRODUCING COMPANY 2840.00 82.00 365
1991 CGAS EXPLORATION 1086.00 0.00 365
1992 CGAS EXPLORATION 2544.00 82.00 366
1993 CGAS EXPLORATION 2271.00 0.00 366
1994 CGAS EXPLORATION 1937.00 94.00 365
1995 CGAS EXPLORATION 2165.00 0.00 365
1996 CGAS EXPLORATION 1695.00 87.00 365
1997 CGAS EXPLORATION 1392.00 0.00 365
1998 CGAS EXPLORATION 794.00 73.00 365
1999 KNOX ENERGY INC. 219.00 0.00 61
2000 KNOX ENERGY INC. 2354.00 0.00 365
2001 KNOX ENERGY INC. 2268.00 0.00 365
2002 KNOX ENERGY INC. 1998.00 0.00 365
2003 KNOX ENERGY INC. 569.00 0.00 13
2004 SELECT ENERGY INVESTMENTS INC 1943.00 0.00 365
2005 SELECT ENERGY INVESTMENTS INC 1336.00 0.00 365
2006 SELECT ENERGY INVESTMENTS INC 2283.00 0.00 365
2007 SELECT ENERGY INVESTMENTS INC 1808.00 0.00 365
2008 SELECT ENERGY INVESTMENTS INC 1653.00 76.00 365
2009 SELECT ENERGY INVESTMENTS INC 1543.00 39.00 365
2010 SELECT ENERGY INVESTMENTS INC 1762.00 0.00 365
2011 SELECT ENERGY INVESTMENTS INC 1454.00 0.00 365
2012 SELECT ENERGY INVESTMENTS INC 1319.00 44.00 366
2013 SELECT ENERGY INVESTMENTS INC 918.00 103.00 365
2014 SELECT ENERGY INVESTMENTS INC 1492.00 0.00 365
2015 SELECT ENERGY INVESTMENTS INC 816.00 0.00 365
2016 SELECT ENERGY INVESTMENTS INC 1128.00 0.00 365
2017 SELECT ENERGY INVESTMENTS INC 1689.00 15.00 365
2018 SELECT ENERGY INVESTMENTS INC 1480.00 35.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 CNG PRODUCING COMPANY Brine 2419 365
1986 CNG PRODUCING COMPANY Brine 1557 365
1988 CNG PRODUCING COMPANY Brine 258 365
1989 CNG PRODUCING COMPANY Brine 1091 365
1990 CNG PRODUCING COMPANY Brine 1325 365
1991 CGAS EXPLORATION Brine 341 365
1992 CGAS EXPLORATION Brine 739 366
1993 CGAS EXPLORATION Brine 1154 366
1994 CGAS EXPLORATION Brine 854 365
1995 CGAS EXPLORATION Brine 888 365
1996 CGAS EXPLORATION Brine 596 365
1997 CGAS EXPLORATION Brine 737 365
1998 CGAS EXPLORATION Brine 496 365
1999 KNOX ENERGY INC. Brine 0 61
2000 KNOX ENERGY INC. Brine 0 365
2001 KNOX ENERGY INC. Brine 0 365
2002 KNOX ENERGY INC. Brine 287 365
2003 KNOX ENERGY INC. Brine 0 13
2004 SELECT ENERGY INVESTMENTS INC Brine 536 365
2005 SELECT ENERGY INVESTMENTS INC Brine 423 365
2006 SELECT ENERGY INVESTMENTS INC Brine 887 365
2007 SELECT ENERGY INVESTMENTS INC Brine 719 365
2008 SELECT ENERGY INVESTMENTS INC Brine 636 365
2009 SELECT ENERGY INVESTMENTS INC Brine 614 365
2010 SELECT ENERGY INVESTMENTS INC Brine 671 365
2011 SELECT ENERGY INVESTMENTS INC Brine 549 365
2012 SELECT ENERGY INVESTMENTS INC Brine 166 366
2013 SELECT ENERGY INVESTMENTS INC Brine 576 365
2014 SELECT ENERGY INVESTMENTS INC Brine 491 365
2015 SELECT ENERGY INVESTMENTS INC Brine 368 365
2016 SELECT ENERGY INVESTMENTS INC Brine 433 365
2017 SELECT ENERGY INVESTMENTS INC Brine 608 365
2018 SELECT ENERGY INVESTMENTS INC Brine 452 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1021372864 2018-10-17 0:00 PW No Violations
-1216762693 2017-6-26 0:00: PW No Violations
-483690588 2013-9-11 0:00: PW No Violations
-603652638 2017-6-26 0:00: AD No Violations
-85114766 2007-9-18 0:00: AD No Violations
0085114766 2007-09-18 Annular Disposal No Violations Well is a rabbit well. Tank battery is signed and fenced. Gate was unlocked. Two 210 and one 110 bbl tank on site and a mechanical separator. Tubing is corroded around the well head. Middle tank is a 210 tank, 2nd ring wield of the tank is rusting out. There is oil leaking down the side of the tank.
0483690588 2013-09-11 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The well and tank battery are in good repair. The tank battery is surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
0567746968 2012-06-11 Annular Disposal No Violations My inspection today found a plunger lift system well in good repair. No annular disposal facilities identified during inspection. Lease road is stable. Identification sign is posted at the tank battery. The tank battery has two 210 barrel production tanks, one of which has been decommissioned. The tank has rusted out at the seams. There is also a 100 barrel brine tank and a mechincal separator in the battery. The 210 production tank in use, has two rust blisters at the bottom of it. Both blisters are approximately 18 inches long and 10 inches tall. Rust scale has flaked off and the blisters are wet. I called the owner of the company and left a message in regards to the status of the tanks and the needed repairs. Owner returned call, he will have tanks assessed and replaced as needed.
0603652638 2017-06-26 Annular Disposal No Violations At the time of this inspection, the well was observed to be equipped with a plunger lift assembly and no annular disposal was present.
1021372864 2018-10-17 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1964155314. At the time of this inspection, the excavated area east of the tank battery dike has been replaced. Seeding and mulching was conducted but no growth of new vegetation was observed. The 100 BBL tank that had previously leaked was still inside the tank battery. The tank had been emptied and cleaned out but still needed removed.

Select Energy Investments still needs to: 1) Remove the 100 BBL tank that had the leak

1084383558 2004-05-03 Production Wells No Violations TB 1-210 BBL &100 BBL ,seperator Well is a rabbit
1159667045 2018-10-03 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1964155314. At the time of this inspection, the standing water in the dike had been removed. The impacted soil on the east side of the tank battery was removed and taken off site.

Select Energy Investments still needs to: 1) Replace the excavated area east of the dike with new soil 2) Remove the 100 BBL tank that had the leak

1216762693 2017-06-26 Production Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. There was a domestic line plumbed off of the 4.5 inch casing with a drip bottle and regulator. Valves on the domestic line were open. Production records for this well were current. The tank battery consisted of one 100 BBL production tank, one 100 BBL brine tank, and a mechanical separator. Valves on the separator were open. The tank battery was diked and fenced. Signage at the tank battery needs to be updated. The lease access was stable. The southeast corner of the tank battery had standing water with an oil sheen on top of the water and was contained within the diked area. Oil absorbant pads were applied to the water. There was a 55 gallon drum within the tank battery adjacent to the oily water and inside of the dike. I contacted Richard Campola, owner/operator from Select Energy Investments about cleaning up the tank battery and removing any impacted soil, the 55 gallon drum, and any residual waste. I also requested he update the signage. Mr. Campola indicated that the company would respond immediately and have the requested items addressed by the end of the current week. No annular disposal was present at the time of this inspection.
1333395034 2012-03-19 Annular Disposal No Violations No annular disposal taking place at this well site.
1542652743 2018-11-19 Production Wells No Violations On location in response to an complaint of natural gas odor in the area, called into the One Call Number on 11/16/2018. No gas odors were noted at the tank battery and the well. There was a production tank laying on its side, outside of the tank battery. There was an escavator on location. I spoke to the owner of the well Richard Compola, he stated had the tank steam cleaned and removed from the battery on 11/15/2018. The tank is schedualed to be repaired and flipped. Once the repairs to the tank are completed the tank will be put back in operation. The production tank is the west tank in the battery. This is the tank that inspector Mullins called out in her inspection report as leaking.
1546533508 2019-01-03 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1964155314. At the time of this inspection, the 100 BBL tank that had a leak was cleaned out, repaired and reinstalled within the diked tank battery. The tank has been put back online and is in compliance. Compliance notice closed.
1964155314 2018-10-02 Production Wells Violations Noted I received a call from well Richard Campola, owner of Select Energy Investments, Inc. Mr. Campola stated that there had been an approximate 20 BBL release of brine into the diked tank battery from a production tank, and some of the brine had leached out along the east side of the battery. Mr. Campola also stated that the one of the 100 BBL tanks had a rotted out base and was responsible for the release. The tank has been emptied and isolated from the other production equipment. At the time of my inspection, I observed a brine scald that was located east of the diked tank battery and measured 21 X 24 feet. The scalded area had some standing water in tire ruts with residual oil on top of the water. I conducted a high range Quantab test on the standing water and the chloride reading was 3944 ppm. The tank battery had was comprised of two 100 BBL tanks and a mechanical separator. The base of the 100 BBL tank near the tank valve was rotted and staining was present. The tank was presently empty of fluid. The diked tank battery was fenced and had standing water in it. I conducted a high range Quantab test of the standing water and chlorides measured 541 ppm. In speaking with Mr. Campola, he stated that the standing water in the dike would be removed. The 100 BBL tank that has been emptied would be removed from the site after steam cleaning it out. The impacted soil on the east side of the tank battery was going to be removed and disposed of. New, clean soil was to replace the impacted soil. While on location, I also spoke with the landowner, Joshua Webb regarding the cleanup that will be conducted by Select Energy Investments.
2038220680 2017-10-25 Production Wells No Violations I conducted a reinspection of the well site regarding the southeast corner of the tank battery area needing cleaned out, and updated requested signage. At the time of this inspection, the southeast corner of the dike had been cleaned up and the 55 gallon drum within the tank battery had been removed. Signage at the tank battery location had also been updated. No violations observed.
567746968 2012-6-11 0:00: AD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1964155314 US-OH-119835 2019-01-14 9-1-07 Well operation causing pollution and contamination
1964155314 US-OH-119836 2019-01-14 9-9-05(A)8 Equipment pressure rated below operating pressure