If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-053-20993 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":38.89,"lon":-82.19,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Gallia | |
Municipality: Addison Township | |
Operator Name: PHILLIPS EXPLORATION INC | |
Well Pad ID: | |
Farm/Lease Name: VAN METER | |
License Status: Final Restoration | |
License Date: 2009-06-08 | |
Spud Date: 2008-03-18 | |
Spud Drilling Contractor: PHILLIPS DRILLING COMPANY | |
Final Drill Date: 2008-03-27 | |
Well Total Depth: 3197.00 ft | |
Configuration: Vertical | |
Latitude: 38.890000 | |
Longitude: -82.190000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-11-30 | Proposed Formations:OHIO SHALE, Issued Date:11/30/2007, Expired Date:11/29/2008 6:00:00 AM, Drilling unit acres:28.59, Proposed Well Type:OG, Proposed Well Class:EDPW |
Reached Total Depth | 2008-03-27 | NO IP VALUES REPORTED |
Completion Report Received | 2008-09-22 | NO IP VALUES REPORTED |
APP | 2009-06-08 | Proposed Formations:OHIO SHALE (CINNAMON), Issued Date:6/8/2009, Expired Date:6/8/2010 6:00:00 AM, Drilling unit acres:28.59, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2010-04-08 | NO IP VALUES REPORTED |
Construction Permit Expires | 2010-06-08 | NO IP VALUES REPORTED |
Record Last Modified | 2017-02-15 | NO IP VALUES REPORTED |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-11-17 | 2540 | 2548 | 8 |
2008-11-17 | 2736 | 2744 | 8 |
2540 | 2548 | 8 | |
2736 | 2744 | 8 | |
2540 | 2548 | 8 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | NO FRAC VOLUMES REPORTED… GM 11/17/08 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PHILLIPS EXPLORATION INC | 0.00 | 0.00 | 0 |
2009 | PHILLIPS EXPLORATION INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PHILLIPS EXPLORATION INC | Brine | 0 | 0 |
2009 | PHILLIPS EXPLORATION INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1056358382 | 2008-8-8 0:00:0 | DD | No Violations | |
-1200079833 | 2008-3-6 0:00:0 | DD | No Violations | |
-1262176552 | 2008-4-8 0:00:0 | DD | No Violations | |
-1490922511 | 2008-4-16 0:00: | DD | No Violations | |
-1669356427 | 2011-11-14 0:00 | FR | No Violations | |
-344859597 | 2008-1-24 0:00: | AM | No Violations | |
-811014682 | 2008-10-9 0:00: | PL | No Violations | |
0142354016 | 2008-05-29 | Production Wells | No Violations | Gas meter for Wells 990 and 993 is located at GPS N 38.90028 W 082.19758. It is 15 from Bulaville Pike Road. |
0147708453 | 2008-03-19 | Drill / Deepen / Reopen | No Violations | Surface Cement Job. Spud 3-18-08. TD 274. 13 conductor 88. 254 of 9 5/8. Good cement returns. Driller is Phillips Drilling Rig #6, It is a RD-20. |
0231142286 | 2008-05-29 | Production Wells | Violations Noted | Id is 2 1/2 by 2 1/8. Separator is 79 from the well. Brine tank is 13 from the well. Tank is not in a dike. Tank doesnt have a label as to what is in it. Catalytic heater is 22 1/2 from the well. A new pit has been dug into the bank at GPS N38.89553 W 082.19766. The original drill pit is located at GPS N 38.89572 W082.19775. |
0241997442 | 2008-03-20 | Drill / Deepen / Reopen | No Violations | They hit water at 1100. Drillers said that it was brine. It is probably the Big Injun. |
0344859597 | 2008-01-24 | Administrative Inspection | No Violations | Tom Baun PC Exploration called me about a permit to cross Campaign Creek with a pipe line. I contacted Joe Hoerst and he said that the Army Corps had the say over jurisdiction. I called Tom back and left a message that he needed to contact the Corps and I gave him the phone number for the Huntington District office. |
0811014682 | 2008-10-09 | Preliminary Restoration | No Violations | Good Id. Good vegetative growth on entire location. Sediment fence has been removed. Tank is in a dike. Spacing is correct. Lease road is gravel all the way to the wellhead. Well is connected to production lines and is capable of production. Fence around wellhead and tank to keep livestock out. Tank valves are locked. |
0882952149 | 2008-03-26 | Drill / Deepen / Reopen | No Violations | Pit liner looks good. They cemented the 7 early this morning. Cement job went well. No problems were observed. |
1010796953 | 2008-01-22 | Drill / Deepen / Reopen | No Violations | Site meeting with Tom Baun from PC Exploration. We went over pit placement and talked about the need to have at least 60 of flow line to the pit while on air and to use a 45 fitting on the end to divert cuttings into the pit. Per the landowners request the diversion ditches along the access road will be channeled into a small pond near the location. |
1056358382 | 2008-08-08 | Drill / Deepen / Reopen | No Violations | Meadows is doing the preliminary restoration. They called and requested that I come out to location to go over specifications on dike size and erosion controls. Pits have been filled in. Top soil has not been spread out yet. Site work looks good at this time. |
1122610629 | 2008-07-15 | Production Wells | No Violations | Pits are closed. Production equipment is disconnected from the well. They are preparing to frac the well a second time. After the frac job the equipment will be installed to meet all spacing requirements. |
1200079833 | 2008-03-06 | Drill / Deepen / Reopen | No Violations | Sediment controls are in place. Pit has been dug but not lined yet. Site looks good. A small pond has been removed with the landowners permission. New gates and electric fence have been installed to keep cows away from the drill site. |
1262176552 | 2008-04-08 | Drill / Deepen / Reopen | No Violations | Pit looks good. Liner is in good shape. No problems at this time. |
142354016 | 2008-5-29 0:00: | PW | No Violations | |
147708453 | 2008-3-19 0:00: | DD | No Violations | |
1490922511 | 2008-04-16 | Drill / Deepen / Reopen | No Violations | Pit level has been pumped down 1.5. Liner looks to be in good shape. They have not fraced the well yet. Lease road is gravel and holding up well. |
1511006517 | 2008-08-20 | Preliminary Restoration | No Violations | Good id. Pits are closed. Tank has a dike. Site has been graded and top soil spread out. Whole site has been hydro seeded. Access road has new gravel from the road to the wellhead. Restoration looks good. I will follow up to check on vegetation growing. |
1669356427 | 2011-11-14 | Final Restoration | No Violations | Site is graded. Good vegetative cover established. |
1854461833 | 2008-03-17 | Drill / Deepen / Reopen | No Violations | Rig is moving on site today. |
2080066975 | 2008-06-13 | Production Wells | No Violations | Bowers has pumped out the pits. A large legible identification is on the tank. They are going to frac the well again soon and will be moving the equipment anyway. When the equipment is reinstalled it will be within the spacing requirements. |
231142286 | 2008-5-29 0:00: | PW | No Violations | |
241997442 | 2008-3-20 0:00: | DD | No Violations | |
882952149 | 2008-3-26 0:00: | DD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0231142286 | US-OH-122302 | 2008-06-04 | General Safety | |
0231142286 | US-OH-122303 | 2008-06-04 | Violation of tank fire heater spacing requirements | |
0231142286 | US-OH-122304 | 2008-06-04 | Violation of separator spacing requirements |
For data sources see[9]