34-035-22200

Well Details

Well ID: 34-035-22200
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: J WELL SERVICE INC
Well Pad ID:
Farm/Lease Name: MATTES
License Status: Producing
License Date: 2012-03-13
Spud Date: 2012-03-27
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2012-04-03
Well Total Depth: 3673.00 ft
Configuration: Vertical
Latitude: 41.320000
Longitude: -81.710000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-03-13 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:3/13/2012, Expired Date:3/13/2014 12:00:00 PM, Drilling unit acres:20.48, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2012-04-03
Completion Report Received 2012-06-21
Construction Permit Expires 2013-03-13
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-07-16 3436 3441 15
2012-07-16 3461 3469 24
3436 3441 15
3461 3469 24
3436 3441 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-05-01 H2O 15 94079 Gal 60000 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 OHIO VALLEY ENERGY SYSTEMS COR 2601.00 161.00 273
2014 OHIO VALLEY ENERGY SYSTEMS COR 3163.00 119.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 2575.00 137.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 1841.00 87.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 646.00 0.00 273
2018 OHIO VALLEY ENERGY SYSTEMS COR 1307.00 89.00 304

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 273
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 791 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 843 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 365 273
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 150 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1016508863 2015-8-28 0:00: UP No Violations
-1429511378 2019-5-1 0:00:0 UP No Violations
-1433692917 2012-11-27 0:00 UL No Violations 1.00
-1665698263 2017-11-8 0:00: UP No Violations 0.50
-506547169 2014-7-14 0:00: UP No Violations
0506547169 2014-07-14 UrbanProduction Wells No Violations I inspected this producing unit as part of customary and routine inspection activities. The unit is producing and production reports are current. ID placards are present and have current and accurate contact information. The tank battery secondary containment dike is is good condittion. The unit lies in a failry level, suburban residential area. Surface runoff is controlled by storm sewer infrastructure. I did not observe any signs of gully formation, wash-outs, or other impacts associated with the unit. Enclosure gates are locked. I did not observe any signs of leakage, spills, or other problem conditions.
0658487783 2017-04-27 UrbanProduction Wells No Violations I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I noted the following: a wellhead with pump-jacksystem and associated tank battery in separate board-on-board enclosures located on a residential parcel. The enclosure gates were locked and secure. Fittings and connections at the wellhead were secure. The pump-jack supports were solid. The stuffing box fitting was secure with no significant leaks. The bridle attachments were secure. Fittings and connections at the battery were secure. The load-line valves were plugged and locked. The tank lids were closed and sealed. The secondary containment drain was secure. There was some standing water in the containment area from recent rainfall. The water was clear with no signs of floating oil or sheen. The road is comprised of a shared-use, concrete driveway which was in god condition. I walked the areas surrounding the well and battery systems and observed the natural soils and vegetation to be free from signs of leaks, spills, or other adverse impact from the on-going production activity.
0854270125 2015-06-26 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to an earlier inspection. The wellhead and battery enclosures are locked and secure. Load-lines are locked. Process safety equipment is present and in good condition. The fittings and connections are secure and free from signs of leakage. The owner is working on addendum signage to meet urban requirements.
1016508863 2015-08-28 UrbanProduction Wells No Violations I inspected this producing well location as part of routine inspection activity. The shared driveway access to the tank and battery are in good condition. The gate is secure and ID signage is in place at the entry point. Enclosure gates, load-lines, and electrical boxes are locked and secure. Fittings and connections at the wellhead are secure. The battery secondary containment is intact, and free from signs of leakage. Areas around the well and battery consist of well-manicured lawn. I did not observe any signs of problems at the time of this inspection. I contacted the emergency number listed to confirm accuracy. The number is functioning and correct.
1052899167 2015-05-22 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. The well is producing and production records are current. Entry gates are locked and secure, at both the wellhead and battery. Process safety equipment is present. Fittings and connections are secure and free from signs of leakage or problems. At the time of this inspection, I observed the following deficiencies: the load lines are not lock protected, the electrical box is not lock protected, there is an unprotected extension cord running over ground between the tank battery and the wellhead. There is no evergreen screening which is required as part of site restoration, unless waived by the landowner. ID signage is lacking required information. Warning signage is incomplete. These deficiencies must be corrected as soon as practicable or by 06/29/2015. Please contact Inspector Stephen Tompkins at 330-907-4647 for questions regarding this inspection.
1197045446 2015-01-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead pump jack system enclosure is open on one side. Valves and connections are secure and free from signs of leakage problems. At the time of my inspection, the area is covered with several inches of snow. Access to the wellhead and battery are via the shared residential driveway which is snowed in but passable. Valves and connections at the battery are secure. Load-outs are bull-plugged and locked. I did not observe any problems at the time of this inspection.
1335200328 2012-04-23 UrbanProduction Wells No Violations My inspection of this well following completion of drilling process found that the pits have been closed. Company has begun preliminary restoration of site. Well head is enclosed with temporary fencing. Tank battery to be installed week of April 28, 2012. Property owner will complete landscaping of site following completion of well installation.
1429511378 2019-05-01 UrbanProduction Wells No Violations No violations found. All locks, safety equipment, and fencing around well head and tank battery have been installed. Proper identification was posted at well and tank battery. Supervisor Tom Hill emailed Rick Little to address water issue inside of tank battery.The tank battery floor was covered with approximately six inches of storm water.

Following maintenance issues must be addressed: 1. Water needs to be drained from tank battery.

1433692917 2012-11-27 UrbanPreliminary Restoration No Violations On my visit to the well today I was accompanied by Steve Tompkins, Lake County Inspector, DOGRM. The purpose of the inspection was to perform an Urban Preliminary Restoration Inspection. The access road is concrete for the first one hundred feet off the roadway. The well head is enclosed by board on board fencing and is secured with chains and locks. There are no violations at the well head. The tank battery is enclosed inside board on board fencing and is locked and secured by locks and chains. There is one 140 BBL storage tank and one 70 BBL brine tank. There is one vertical and one horizontal separator unit in the tank battery. There is a metering run also. Pick up lines are enclosed in the tank battery and secured by locks and bull plugs. The area has been seeded and grass is growing through out the well site. No violations found. Urban Preliminary Inspection passed.
1473002898 2020-3-11 0:00: UP No Violations 0.50
1594302448 2020-7-8 0:00:0 UP No Violations 0.50
1665698263 2017-11-08 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and associated battery are located on a single-family residential parcel. At the time of my inspection, the fittings and connections at the well were secure. The tank lid was closed and secure. The load-line valves were plugged and locked. I walked and inspected the areas surrounding the wellhead and battery and found no signs or evidence of impacts or degradation.
1727151409 2020-7-9 0:00:0 UP No Violations
1981438952 2018-06-21 UrbanProduction Wells No Violations I inspected this well as part of routine inspection. Fittings and connections at the well and battery were secure and free from leakage or problems. The tank lids were closed. The secondary containment was intact and dry. The individual enclosure gates were locked. Production reports were current and up-to-date, but the well was not producing at the time of my inspection. The shared-use access road was in good condition. I walked and inspected the areas surrounding the wellhead and battery and found the natural greenscape to be free from signs of impact or degradation.
658487783 2017-4-27 0:00: UP No Violations 0.50
854270125 2015-6-26 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1052899167 US-OH-100909 2016-07-26 9-05E1 ID (a-i)
1052899167 US-OH-100910 2015-11-13 LOCKS

For data sources see[9]