X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22193

Well Details

Well ID: 34-035-22193
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: MOORE RESOURCES LLC
Well Pad ID:
Farm/Lease Name: BECKER
License Status: Producing
License Date: 2011-07-08
Spud Date: 2011-08-15
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2011-08-19
Well Total Depth: 3675.00 ft
Configuration: Vertical
Latitude: 41.310000
Longitude: -81.700000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-07-08 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:7/8/2011, Expired Date:7/7/2013 12:00:00 PM, Drilling unit acres:21.546, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-08-19
Completion Report Received 2011-12-30
Construction Permit Expires 2012-07-07
Change of Owner 2017-05-22 Operator changed from 1249, CUTTER OIL CO to 7988, MOORE RESOURCES LLC
Record Last Modified 2017-06-22

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-03-05 3414 3418 8
2012-03-05 3431 3439 24
3414 3418 8
3431 3439 24
3414 3418 8

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-10-17 H2O 15 90000 Gal 0 Universal Well Services Inc. 15 balls dropped, acid flush
2011-10-17 H2O 15 90000 Gal 50000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 CUTTER OIL COMPANY 0.00 0.00 44
2012 CUTTER OIL COMPANY 21408.00 766.00 366
2013 CUTTER OIL COMPANY 8218.00 302.00 365
2014 CUTTER OIL COMPANY 4889.00 381.00 365
2015 CUTTER OIL COMPANY 3382.00 198.00 365
2016 CUTTER OIL COMPANY 2623.00 98.00 365
2017 MOORE RESOURCES LLC 984.00 0.00 365
2018 MOORE RESOURCES LLC 737.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 CUTTER OIL COMPANY Brine 2809 44
2012 CUTTER OIL COMPANY Brine 1275 366
2013 CUTTER OIL COMPANY Brine 590 365
2014 CUTTER OIL COMPANY Brine 526 365
2015 CUTTER OIL COMPANY Brine 421 365
2016 CUTTER OIL COMPANY Brine 432 365
2017 CUTTER OIL COMPANY Brine 0 120
2018 MOORE RESOURCES LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1059124342 2013-10-28 0:00 UP No Violations
-1171308462 2011-10-31 0:00 PW No Violations 2.00
-1199452538 2012-11-6 0:00: UL No Violations
-2121924951 2012-4-23 0:00: UP No Violations 1.00
-407664270 2012-11-28 0:00 UL No Violations 1.00
-928351802 2015-5-7 0:00:0 UP No Violations
0100423335 2014-02-20 UrbanProduction Wells No Violations The unit is producing with no changes observed since the last inspection. No violations or problems.
0348672969 2011-10-27 Production Wells No Violations DNR Inspector Ray Wallace met with DNR Supervisory Inspector Gene Chini as a follow up to the previously filed report concerning the Becker Well #1, and to give to DNR Supervisor Chini information regarding the complaint from the previous evening. DNR Supervisor Chini contacted Angelina Barone, a reporter for Action 19 news.
0407664270 2012-11-28 UrbanPreliminary Restoration No Violations My visit to the well today was to conduct an Urban Preliminary Restoration Inspection. Access road is concrete for the first 60 feet, then crushed limestone and brick throughout the remainder of the well site. Grass has been seeded and restored to specifications in the pre site report. The well head is encased inside a board on board fence mounted on top of a dike surrounding the well head. The gate into the well head is secured by lock and chain and is secure. No issues or violations are noted. The tank battery is enclosed inside board on board fence on top of the dike surrounding the tank battery. Pine stock is planted on the dike for erosion control. The dike is capable of holding the amount of fluid prescribed in 1501:09-5-5. The tank battery has two 140 BBL storage tanks and 140 BBL brine tank. Caps on storage tanks are closed and secure. There are vent caps in place as well as a charcoal filter unit. There is one vertical and one horizontal separator, one metering run and load lines which are secured by locks and bull plugs. There are no violations noted. Urban Preliminary Restoration passed.
0523072166 2015-11-12 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to a previously-issued Compliance Notice. At the time of this inspection, load-outs and electrical boxes are locked. Tank lids are secure. Signage has been corrected and updated. Oil staining at the Balon valve has been remediated. The previously-identified safety and maintenance issues have been addressed. I walked the area around the wellhead and the battery. I did not observe any signs of impact or contamination relating to the on-going production activity. The shared access road is in good condition.
0928351802 2015-05-07 UrbanProduction Wells Violations Noted I inspected this well location as part of routine inspection activity. The well is located behind a single-family dwelling on Royalwood Road. There is a short access road beyond the shared driveway. At the time of this inspection, there are no wash-outs or erosional deficits. The wellhead is comprised of a pump jack unit in a board-on-board enclosure which is locked. The entry door is secure and locked. At the time of this inspection, the following maintenance issues were noted: The permit number indicated on the signage is incorrect. Electrical boxes are not locked. Production tank lids are not latched down as required. Signage is present but lacking complete information. There is some oil leaking at the back-pressure (Baird) valve and at the stuffing box. An empty 55-gallon drum and chemical pump should be removed if not used. Carbon filters must be periodically evaluated for properly operation. In addition, the following safety issues were noted. Load lines are not locked. These safety issues must be remedied as soon as practicable or by 06/19/2015. Please contact Inspector Stephen Tompkins with questions regarding this Compliance Notice.
100423335 2014-2-20 0:00: UP No Violations
1059124342 2013-10-28 UrbanProduction Wells No Violations The unit is currently producing with no problems noted.
1171308462 2011-10-31 Production Wells No Violations DNR Inspector Ray Wallace travelled to Becker Well #1 to meet with Cutter Oil employees. Talked with CJ Cutter, President of Cutter Oil. Well is currently shut in, and company will not be putting well into service until at least Wednesday, 11/02/2011. Cutter explained that problem arose due to a foreign object in the stem and seat of the dump valve, allowing gas to bypass into the atmosphere. Cutter Oil has been in contact with the gas service company concerning getting the service/sales line in service. Waiting for the response of the Dominion/East Ohio gas company at this time.
1199452538 2012-11-06 UrbanPreliminary Restoration No Violations On my inspection of this well for preliminary restoration I was accompanied by Supervisor Tom Hill. My inspection found a small puddle of oil at the stuffing box with diapers soaking up the oil. Company was notified by phone to make repairs as needed. No violation to be issued. A follow up inspection will be conducted within 30, days. The wellhead is in good operating order and is enclosed in a board on board fence and is secured with locks. There is 200 PSI at the annulus. The tank battery is enclosed in a board on board fence and has two 140 Barrel lowboy tanks with vent caps in place. There is a charcoal filter in place and spark arrestors on the tanks. There is one 70 Barrel lowboy brine tank, metering run and a separator. There are two load lines which are secured with locks. Well is in compliance with 1501:9-9-05. Urban Preliminary restoration not passed until follow up inspection to be performed.
1281336536 2015-01-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead pump jack enclosure is secure. Valves and connections are secure and free from signs of leakage or problems. At the time of my inspection, the area is covered with several inches of snow. Access to the well and battery is from the rear portion of the house at this address. The driveway is clear and snow has been plowed. Load-outs are bull-plugged and locked. I did not observe any problems at the time of this inspection.
1317304694 2011-08-12 Drill / Deepen / Reopen No Violations I received a phone call from Deputy Chief Tom Tugend asking me to check this site. Director Mustine sent him a letter he received letter from Michelle Aini, who lives on the street behind this well site (3128 Osage Way). She is concerned about the number of wells in Broadview Hts, the proximity of this well to her home and also if this well will be fraced when it is completed. I called Deputy Chief Tugend to report that I found no violation and that the well is in compliance.


NO VIOLATION FOUND

1320066357 2011-10-27 Production Wells No Violations On 10/27/2011 Inspector Ray Wallace received a phone call from DNR Inspector Norburt Lowder at approximately 5:45 PM, that he had received a call from Michele Aini, 3128 Osage Way, Broadview Heights, OH. Complaint was a very strong odor of gas from the vicinity of the Becker well #1, permit # 22193, located at 2779 Royalwood Road, Broadview Heights, OH. Upon further investigation following several phone calls to City Building department, (Roger), and Fire chief, (Jeffrey Hajek), discovered that fire department had been on scene at 3092 Osage Way earlier in the day, (Lisa Sabula), property is located due south of the tank battery. Call to BHFD came in at 3:51 PM, BHFD on scene at 3:53 PM. Cutter oil employees were on site. Fire Department inspected area of tank battery and found an open 2 fitting hole not covered in one of the tanks. Fire department took reading of 2% LEL at tank battery area. Open hole was for stem and seat of dump valve for tanks. Cutter employees placed a plug in the hole, and fire department rechecked LEL and readings were zero. Fire department cleared scene at 4:36 PM. ODNR was not notified by either BHFD or Cutter Oil of this incident. Inspector Wallace contacted Mrs. Aini, who complained about the earlier complaint and stated that there was still an odor in the air. Inspector Wallace attempted to contact CJ Cutter, (well owner), and President of Cutter oil. Mrs. Ainis property is located approximately 600 SSW of the well head. Mr. Cutter contacted DNR Inspector Wallace at about 7:40 PM and informed him that he had company representative Tony Horvath shut the well down, and to remove it from service. Inspector Wallace called Mrs. Aini to inform her that the well had been shut down and would remain that way until Friday morning. DNR Inspector Wallace further informed her that he would not be traveling to the well site, but should any further incidents occur, feel free to call him and he would travel to the well site. Cutter oil needs to pay mor
1330449072 2012-02-28 UrbanProduction Wells No Violations Well inspected at request of nearby resident. No violations found. Well is in compliance with 1501:9-9-05.
1513791984 2017-12-20 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located behind a single-family residence. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. The load-lines were plugged, locked, and secure. The tank lids were closed and sealed. The well was in production with an active chart record. I walked the areas surrounding the well and found no signs of problems or impacts relating to the production operation.
1760446468 2011-09-14 Urban Drill / Deepen / Reopen No Violations Crew working on the tank battery area - temporary fenceing up and erosion controls in place.
1834507768 2020-3-9 0:00:0 UP No Violations
2121924951 2012-04-23 UrbanProduction Wells No Violations My inspection today found no violations. Well is in compliance.
348672969 2011-10-27 0:00 PW No Violations
523072166 2015-11-12 0:00 UP No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0928351802 US-OH-130602 2016-04-27 LOCKS

For data sources see[9]