34-035-22186

Well Details

Well ID: 34-035-22186
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: M WITTENMYER
License Status: Producing
License Date: 2012-05-17
Spud Date: 2012-06-12
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2012-06-17
Well Total Depth: 3185.00 ft
Configuration: Vertical
Latitude: 41.330000
Longitude: -81.800000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-01-07 Proposed Formations:CLINTON, Issued Date:1/7/2011, Expired Date:1/6/2013 12:00:00 PM, Drilling unit acres:20.58, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2011-01-14 Proposed Formations:CLINTON, Issued Date:1/14/2011, Expired Date:1/13/2013 12:00:00 PM, Drilling unit acres:20.58, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2012-05-17 Proposed Formations:CLINTON, Issued Date:5/17/2012, Expired Date:5/17/2014 12:00:00 PM, Drilling unit acres:20.58, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2012-06-17
Completion Report Received 2012-09-24
Construction Permit Expires 2013-05-17
Change of Owner 2015-11-03 Operator changed from 7626, M & M ROYALTY LTD to 9312, FO ENERGY LLC
Change of Owner 2019-04-23 Operator changed from 9312, FO ENERGY LLC to 4327, SOUND ENERGY CO INC
Record Last Modified 2019-04-23

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-09-27 2977 2990 27
2012-09-27 2996 3000 9
2977 2990 27
2996 3000 9
2977 2990 27

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-08-22 H2O 0 50525 Gal 50000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 M & M ROYALTY LTD 0.00 0.00 0
2013 M & M ROYALTY LTD 0.00 110.00 60
2014 M & M ROYALTY LTD 3453.00 1088.00 365
2015 M & M ROYALTY LTD 3434.00 518.00 304
2016 FO ENERGY LLC 3149.00 439.00 366
2017 FO ENERGY LLC 2094.00 381.00 365
2018 FO ENERGY LLC 2126.00 497.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 M & M ROYALTY LTD Brine 0 0
2013 M & M ROYALTY LTD Brine 45 60
2014 M & M ROYALTY LTD Brine 238 365
2015 M & M ROYALTY LTD Brine 238 304
2016 FO ENERGY LLC Brine 344 366
2017 FO ENERGY LLC Brine 154 365
2018 FO ENERGY LLC Brine 381 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1120987475 2018-4-13 0:00: UP No Violations 1.00
-1303283728 2012-6-11 0:00: UD No Violations
-312632495 2012-6-13 0:00: DD No Violations 3.00
-54215457 2014-7-7 0:00:0 UP No Violations
0054215457 2014-07-07 UrbanProduction Wells No Violations I inpected this producing unit as part of routine inspection activity and also as a follow-up to my last inspection. At the time of my last inspection, production of this unit had been stopped temporarily pending resolution of a technical problem with the metering connection with Columbia Gas. The well is currently still idle pending the solution. I did not observe any problems, leaks, spills, or other issues.
0312632495 2012-06-13 Drill / Deepen / Reopen No Violations My visit to the well was to witness the cementing of the surface casing. Cement reports will be filed upon completion of the well drilling process. I also witnessed the Blow Off Preventer test on the evening of 06/13/2012.
1120987475 2018-04-13 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: one wellhead with pump jack system in a chain-link enclosure and battery in a separate chain-link enclosure. The enclosure gates were locked and secure. Fittings and connections at both the wellhead and the battery were secure and free from leakage or problems. The tank lids were closed and sealed. The load-line valves were plugged and locked. Signage was present, indicating the new owner/operator. Secondary containment was intact. The dedicated access road was in good condition.
1299519894 2011-01-11 Administrative Inspection No Violations Held on site meeting to discuss permit conditions and site construction.
1303283728 2012-06-11 Urban Drill / Deepen / Reopen No Violations My visit to the well was to inspect well site construction and rig move on and set up. Best Management Practices for site construction are being employed, in addition pre permit conditions are being adhered to. Rig is on site and is beginning to rig up.
1339450379 2012-06-17 Urban Drill / Deepen / Reopen No Violations My visit to the well today was to witness cementing of production casing. From home to site and return encompassed 4 hours. Cement report to follow completion of well.
1371998397 2012-06-13 Urban Drill / Deepen / Reopen No Violations My inspection found the rig shut down and waiting for cement to set. They will conduct the Blow Out Preventor test later tonight (tentative time of 8 PM). DNR Inspector Ray Wallce is schduled to witness this test. No violations found.
1378400337 2013-09-05 UrbanPreliminary Restoration No Violations The producing unit consists of a producing wellhead with pumpjack and aboveground storage tank battery. The wellhead and tank battery are enclosed in separate chain-link fences. The battery is comprised of three 100-barrel production tanks and one 50-barrel brine tank. The secondary containment is good. 1501:9-9-05E safety equipment is present. There is no screening at the wellhead or battery. This will be required if not already waived. Preliminary restoration is pending verification.
1385402919 2013-11-25 UrbanProduction Wells No Violations This unit reportedly has been shut-in following a valve failure at the sales line which caused oil to infiltrate Columbia Gas distribution network. M & M has requested an allowance to operate a flare on a temporary basis which would allow them to continue to produce oil from the unit.

For data sources see[9]

References