X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22183

Well Details

Well ID: 34-035-22183
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: SLAWINSKI UNIT
License Status: Producing
License Date: 2010-09-21
Spud Date: 2011-08-30
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2011-08-29
Well Total Depth: 3814.00 ft
Configuration: Directional
Latitude: 41.330000
Longitude: -81.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-09-21 Proposed Formations:ORISKANY/NEWBURG/CLINTON, Issued Date:9/21/2010, Expired Date:9/20/2012 12:00:00 PM, Drilling unit acres:21.94, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-08-29
Construction Permit Expires 2011-09-21
Completion Report Received 2011-12-19
Change of Owner 2018-08-21 Operator changed from 3434, GONZOIL INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2018-08-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-01-12 3562 3607 24
3562 3607 24
3562 3607 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-09-13 H2O 15 73093 Gal 60000 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 GONZOIL INC 21053.00 3540.00 366
2013 GONZOIL INC 17315.00 2342.00 365
2014 GONZOIL INC 9496.00 1473.00 365
2015 GONZOIL INC 7125.00 1066.00 365
2016 GONZOIL INC 4853.00 538.00 365
2017 GONZOIL INC 5215.00 833.00 365
2018 GONZOIL INC 375.00 403.00 180

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 GONZOIL INC Brine 748 366
2013 GONZOIL INC Brine 229 365
2014 GONZOIL INC Brine 106 365
2015 GONZOIL INC Brine 120 365
2016 GONZOIL INC Brine 83 365
2017 GONZOIL INC Brine 0 365
2018 GONZOIL INC Brine 0 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1105849717 2011-3-2 0:00:0 UP No Violations
-1414128322 2017-2-1 0:00:0 UP No Violations 1.00
-587474669 2014-12-12 0:00 UP No Violations
-638047129 2018-6-19 0:00: UP No Violations 0.50
0587474669 2014-12-12 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead and tank battery are located behind a single-family residence on Avery Rd. Fittings and connections at the linear rod pump and battery are secure and free from signs of leakage or problems. The interior of the secondary containment is clean and dry. Load-outs are plugged and gates are locked. Signage is present and the access road which extends east from the shared driveway is in good condition. There is an area east of the wellhead which is exhibiting ponded water and drainage is poor. The condition may have been extant prior to the presence of the well, but warrants monitoring.
0638047129 2018-06-19 UrbanProduction Wells No Violations I inspected this well as part of routine inspection. At the time of this inspection, the fittings and connections at the wellhead and battery were secure. I noted some oil staining around the base of the wellhead that had been mitigated with some sorbent material. There was no apparent on-going leak. I contacted Gonzoil and advised them that the sorbent material should be removed. Otherwise, I noted that tank lids were closed and secure. Load-lines were locked and secure. The chart record was active. Production reports were current. Enclosure gates were locked. Tank lids were closed and secure. I walked the areas surrounding the well and battery and found normal conditions of the extant greenscape.
1105849717 2011-03-02 UrbanProduction Wells No Violations No Violations
1380822067 2013-10-03 UrbanProduction Wells No Violations The producing unit consists of a vertical piston unit at the wellhead and an aboveground storage tank (AST) battery. The battery is comprised of 2 140-barrel steel production tanks, a 50-barrel brine tank, and a separator unit. There is a Dominion metering run in the battery. The elements are enclosed in separate board-on-board enclosures. There is also a separately enclosed heater unit. There is adequate secondary containment. The signage is in good condition. Urban drilling process safety equipment is present. The load outs are locked and bull-plugged.
1399393870 2014-05-06 UrbanPreliminary Restoration No Violations The area around the unit has been restored. The pits have been filled, regraded, and seeded. The access road is gravel paved and the drainage appears to be properly managed and controlled. No signs of erosion (i.e. down cutting or gully formation). The wellhead is fitted with a linear rod pump which is in operation. The backside 8.625-inch casing is plumbed back to the production line. Pressure at the surface casing is reading 125 PSI. The tank battery load-outs are locked and bull-plugged. The secondary containment is present and in good condition. Spark arrestors, low-pressure relief valves, and carbon filters are present. Evergreen screening is present but appears to be not in accordance with the rule. I will check with Gonzoil to check on possible landowner waiver on this issue. ID placards are present as well as warning signage as required. The dedicated entry gate is locked and has appropriate signage. I observed some standing water near the wellhead area. I tested the water for the presence of brine with Quantab high and low range. The reading indicated less than 60 ppm chloride, which is indicative of fresh water and therefore normal runoff. I did not observe any other signs of leaks, spills or other problems.
1414128322 2017-02-01 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection I observed the following: Access to the well and battery are afforded by an unpaved access road that extends beyond the paved driveway for the house at this parcel. The access road and areas in and around the well were mostly snow covered, but were in good condition with no signs of erosional deficits or degradation. The production system was comprised of a linear ord pump system and tank battery in separate board-on-board enclosures located in close proximity. The enclosure gates were closed and locked. The pump jack was in operation with no evidence of problems or leakage. I walked the interior of the tank battery enclosure and inspected the tanks and associated fittings, connections, and pipe runs. I did not observe any signs of leakage or spills. The tank load line valves were plugged and locked. The tank lids were closed. I walked the areas surrounding the wellhead and battery and found no evidence of impact or degradation.

For data sources see[9]

References