34-035-22123

Well Details

Well ID: 34-035-22123
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: BOGOMOLNY UNIT
License Status: Producing
License Date: 2009-07-17
Spud Date: 2009-09-02
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2009-09-11
Well Total Depth: 3533.00 ft
Configuration: Vertical
Latitude: 41.550000
Longitude: -81.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-07-17 Proposed Formations:CLINTON, Issued Date:7/17/2009, Expired Date:7/17/2010 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-09-11
Completion Report Received 2009-10-19
Construction Permit Expires 2010-07-17
Change of Owner 2019-05-30 Operator changed from 169, JAMES R SMAIL INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2019-05-30

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-01-05 3337 3359 23
3337 3359 23
3337 3359 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 75000 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 JAMES R SMAIL INC 22847.00 272.00 365
2011 JAMES R SMAIL INC 32689.00 255.00 365
2012 JAMES R SMAIL INC 30514.00 129.00 366
2013 JAMES R SMAIL INC 25119.00 39.00 365
2014 JAMES R SMAIL INC 20799.00 115.00 365
2015 JAMES R SMAIL INC 16873.00 98.00 365
2016 JAMES R SMAIL INC 13878.00 53.00 365
2017 JAMES R SMAIL INC 12164.00 0.00 365
2018 JAMES R SMAIL INC 10071.00 69.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 JAMES R SMAIL INC Brine 302 365
2011 JAMES R SMAIL INC Brine 196 365
2012 JAMES R SMAIL INC Brine 236 366
2013 JAMES R SMAIL INC Brine 60 365
2014 JAMES R SMAIL INC Brine 60 365
2015 JAMES R SMAIL INC Brine 76 365
2016 JAMES R SMAIL INC Brine 108 365
2017 JAMES R SMAIL INC Brine 40 365
2018 JAMES R SMAIL INC Brine 66 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1590051638 2017-3-13 0:00: UP No Violations 0.50
-1608542335 2009-9-4 0:00:0 DD No Violations
-1836676599 2013-2-25 0:00: UP No Violations
-231869213 2009-10-14 0:00 DD No Violations
-5547187 2009-9-1 0:00:0 DD No Violations
-587769036 2009-9-2 0:00:0 DD No Violations
0005547187 2009-09-01 Drill / Deepen / Reopen No Violations Rig moving on location, silt fence and orange fence up around location.
0231869213 2009-10-14 Drill / Deepen / Reopen No Violations pits closed
0386470308 2009-09-10 Drill / Deepen / Reopen No Violations on site inspection drilling at 3200, No violation found at this time.
0587769036 2009-09-02 Drill / Deepen / Reopen No Violations on site to witness conductor cementing.
1254838595 2009-09-03 Drill / Deepen / Reopen No Violations on site to witness surface job
1327081420 2011-12-28 UrbanPreliminary Restoration No Violations On 12/28/2011, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
1590051638 2017-03-13 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection. At the time of this inspection I observed the following: a wellhead with pump jack system and associated tank battery. The battery was located in a board-on-board enclosures which was locked and secure. The wellhead was not enclosed. The valves and connections at both the well and battery were secure and free from signs of leakage. Process safety equipment was present. ID signage was present and accurate. The well was located in a meadow area behind a gated entry. The area surrounding the battery was comprised of a light wooded area. I walked the surrounding areas and found no signs of impacts or degradation. Access to the battery was afforded by a dedicated, gravel-paved access road, with a locked access gate. The access road was sound and well drained with no wash-outs or other erosional deficits. Access to the wellhead was afforded by the shard-use, asphalt-paved driveway which was in good condition.
1608542335 2009-09-04 Drill / Deepen / Reopen No Violations on site inspection found no violation drill at 1480 . company plans to drill to 1600 then shut down for the weekend.
1836676599 2013-02-25 UrbanProduction Wells No Violations The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead consists of a pumpjack system in a 6 enclosure. The tank battery is comprised of 1 100-barrel (BBL) tank, 10 BBL poly tank, mechanical separator, and associated piping and appurtenances enclosed in an 8 enclosure. The system is equipped with production safety equipment required by 1509:9-9-05. The loadout lines are locked and the secondary containment is good. I did not observe any leaks, releases, or problems.
386470308 2009-9-10 0:00: DD No Violations

For data sources see[9]

References