X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22121

Well Details

Well ID: 34-035-22121
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: CUTTER OIL COMPANY
Well Pad ID:
Farm/Lease Name: GLUS UNIT
License Status: Final Restoration
License Date: 2015-08-31
Spud Date: 2009-07-14
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2009-07-20
Well Total Depth: 3630.00 ft
Configuration: Vertical
Latitude: 41.320000
Longitude: -81.720000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-07-01 Proposed Formations:OHIO SHALE TO CLINTON, Issued Date:7/1/2009, Expired Date:7/1/2010 6:00:00 AM, Drilling unit acres:31.9922, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-07-20
Completion Report Received 2009-09-11
Correction to Well 2011-02-25 UNIT SIZE REDUCED TO 28.2522 ACRES.
APP 2015-08-31 Proposed Formations:CLINTON, Issued Date:8/31/2015, Expired Date:8/30/2017 12:00:00 PM, Drilling unit acres:31.9922, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2015-10-13
Construction Permit Expires 2016-08-30
Record Last Modified 2017-07-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-10-27 3391 3408 35
3391 3408 35
3391 3408 35

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 200 Mscf 60000 FRAC INVOLVED 89,480 BBLS OF FLUID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 CUTTER OIL COMPANY 0.00 0.00 17
2010 CUTTER OIL COMPANY 8063.00 2467.00 365
2011 CUTTER OIL COMPANY 15858.00 745.00 365
2012 CUTTER OIL COMPANY 7265.00 292.00 366
2013 CUTTER OIL COMPANY 7280.00 327.00 365
2014 CUTTER OIL COMPANY 5593.00 102.00 365
2015 CUTTER OIL COMPANY 83.00 0.00 181

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 CUTTER OIL COMPANY Brine 2100 17
2010 CUTTER OIL COMPANY Brine 1223 365
2011 CUTTER OIL COMPANY Brine 783 365
2012 CUTTER OIL COMPANY Brine 831 366
2013 CUTTER OIL COMPANY Brine 456 365
2014 CUTTER OIL COMPANY Brine 513 365
2015 CUTTER OIL COMPANY Brine 144 181

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1125110678 2015-6-26 0:00: UP No Violations
-1835344116 2015-7-13 0:00: UP No Violations
-1930126979 2015-8-28 0:00: UP No Violations
-315095066 2010-4-5 0:00:0 PL No Violations
-474508700 2015-1-29 0:00: UP No Violations 0.50
-914004882 2016-11-14 0:00 FR No Violations 2.00
-989772741 2011-9-7 0:00:0 UP No Violations
0315095066 2010-04-05 Preliminary Restoration No Violations
0474508700 2015-01-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead pump jack system enclosure is secure. Valves and connections are secure and free from signs of leakage or problems. At the time of my inspection, the area is covered with several inches of snow. Access to the wellhead and battery are via a dedicated access road which has been plowed and is passable. Valves and connections at the battery are secure. Load-outs are bull-plugged and locked. I did not observe any problems at the time of this inspection.
0889348051 2013-10-28 UrbanProduction Wells No Violations The producing unit consists of a wellhead with pump jack and above-ground storage tank (AST) battery. The battery is comprised of 2 140-barrel steel production tanks, 1 50-barrel brine tank and separator unit. There is also a skid-mounted compressor unit, and Dominion metering run. Both the wellhead and battery are enclosed in separate board-on-board fences. The gates and load-outs are locked. ID placard and secondary containment are good. Process safety gear (spark arrestor, low-pressure relief valve, carbon filter) is present. No problems noted.
0914004882 2016-11-14 Final Restoration No Violations I inspected this former well location as an evaluation for Final Restoration requirements. Plugging and abandonment was completed on 10/13/2015 and a report detailing these activities was submitted. At the time of this inspection, the former locations of the well and battery have been restored. The area was graded and seeded with a good establishment of grassy vegetation with no signs of the former production elements. A portion of the access road, which had been gravel-paved was left in place, as well as the electricity supply line, per agreement with the landowner for which a Landowner Waiver (Form 5) remains pending. Final Restoration will not be approved until a waiver is submitted or the the elements removed. Ive contacted Cutter Oil and they are attempting to secure the waiver.
0985728980 2017-05-25 Final Restoration No Violations I inspected this former well location as an evaluation for Final Restoration requirements. Plugging and abandonment was completed on 10/13/2015 and a report detailing these activities was submitted. At the time of this inspection, the former locations of the well and battery have been restored. The area was graded and seeded with a good establishment of grassy vegetation with no signs of the former production elements. A portion of the access road, which had been gravel-paved was left in place, as well as the electricity supply line, per agreement with the landowner for which a Landowner Waiver (Form 5) has been submitted. Final Restoration is complete.
0989772741 2011-09-07 UrbanProduction Wells No Violations Urban Producing well status check. No violations found. Well is in compliance with 1501-9-9-05.
1125110678 2015-06-26 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to an earlier inspection. I had notified the owner/operator and the issue was resolved. The wellhead and battery enclosures are locked and secure. Load-lines are locked. Process safety equipment is present and in good condition. The fittings and connections are secure and free from signs of leakage. The owner is working on addendum signage to meet urban requirements.
1280185491 2015-05-07 UrbanProduction Wells Violations Noted I inspected this well location as part of routine inspection activity. The well is located behind a single-family residence. There is an unpaved access road which travels east from Broadview Road. At the time of this inspection, there are no wash-outs or erosional deficits. The wellhead is comprised of a pump jack unit in a board-on-board enclosure which is locked. The tank battery is comprised of a total of two 100-barrel steel production tanks, one 50-barrel poly brine tank, and mechanical separator. The entry door is secure and locked. At the time of this inspection, the following maintenance issues were noted: Electrical boxes are not locked. Production tank lids are not latched down as required. Evergreen screening is required at the battery and wellhead. There is some remnant silt fence which should be maintained or removed if no longer needed. The entry point requires a locked, gated entry with signage. The 8.625-inch casing is not exposed at the surface to facilitate monitoring as required. Signage is present but lacking complete information. There is gas leakage at the back-pressure (Baird) valve. An empty 55-gallon drum and chemical pump should be removed if not used. Carbon filters must be periodically evaluated for proper operation. In addition, the following safety issues were noted. Load lines are not locked. Brine is actively leaking from the 2-inch flange at the brine tank. Lightning arrestors are missing from the production tanks. These safety issues must be remedied as soon as practicable or by 06/19/2015. Please contact Inspector Stephen Tompkins with questions regarding this Compliance Notice.
1352915998 2012-11-14 UrbanPreliminary Restoration No Violations My visit to this well was for an Urban Preliminary Inspection. Wellhead is in good operating condition and consists of a pump jack style unit. There is no evidence of any leaks, spills or poor conditions. The tank battery consists of two (2) 100 Barrel lowboy tanks with vents and a laser meter to read oil and gas levels in the tanks. All caps and plugs are secure and there are no locks on the load lines, however they are behind a locked gate and are not accessible to the public. There is one 50 Barrel brine tank and one separator in the unit. Fence is board on board and the dike around the tank battery is capable of containing fluids to the standards in 1501:9-9-05. Preliminary restoration passed.
1385410368 2015-10-13 Plug / Plug Back No Violations I was on location pursuant to notification of planned plugging and abandonment activity. Prior to my arrival, crews from the owner/operator had dismantled the pumping unit and removed the sucker rods and production tubing. Residual pressure had been relieved and the well was open to atmosphere and stable with no appreciable gas being produced. Plugging and abandonment activity were executed in compliance with OAC 1501:9-11. Plugging activity is detailed in the associated plugging report. Upon establishment of the top surface plug, the well was noted to be stable with no gas production. A steel plate with well ID had been prepared and will be secured to the wellhead prior to burial at 30 inches below grade as required. Final restoration activities will be on-going until completion as required. Discussions with the well owner indicate some elements of the access road and the existing sales line may be left in place pending landowner waiver.
1447345651 2015-11-12 Final Restoration No Violations I inspected this well location as an evaluation of on-going site restoration work subsequent to plugging and abandonment which occured last month. At the time of this inspection, the production equipment has beeen dismantled and removed. The former well pad and tank battery areas have been re-graded and seeded. The access road is graded and seeded. Confirmation of the establishment of grass may not occur until spring.
1835344116 2015-07-13 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to Compliance Notice issued on 05/20/2015. At the time of this inspection, the load-lines and electrical box is locked and secure. The surface casing valve is exposed and valved at the surface as required. The secondary containment drain is secure. Tank lids are sealed and secure. Process safety equipment (carbon filter, spark arrestor, low-pressure relief valve) is present and in good repair. The previous safety deficiencies have been corrected. The lack of complete information at the ID signage is in process to be remedied.
1930126979 2015-08-28 UrbanProduction Wells No Violations I inspected this producing unit pursuant to an inquiry by Mayor Stefanik regarding some soil piles which had been delivered near the site. According to Cutter Oil, the well is going to be plugged and abandoned within the next few weeks, and the soil and been brought in and staged on the landowners property in preparation to reclaim the access road. At the time of my inspection I observed 12 piles, each approximately 2 to 3 cubic yards of material, staged along the access road. The well is currently shut-in. Gates, load-lines, and electrical panels are locked and secure. I did not observe any problems during this inspection.
889348051 2013-10-28 0:00 UP No Violations
985728980 2017-5-25 0:00: FR No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1280185491 US-OH-107777 2017-12-01 9-05E3 LOCKS
1280185491 US-OH-107778 2017-12-01 9-05E4 TANKS (a-i)
1280185491 US-OH-107779 2017-12-01 9-1-07 Well operation causing pollution and contamination

For data sources see[9]