Well Details

Well ID: 34-035-22111
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: NICHOLAS
License Status: Producing
License Date: 2009-04-10
Spud Date: 2009-05-06
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2009-05-15
Well Total Depth: 3654.00 ft
Configuration: Directional
Latitude: 41.330000
Longitude: -81.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-04-10 Proposed Formations:CLINTON, Issued Date:4/10/2009, Expired Date:4/10/2010 6:00:00 AM, Drilling unit acres:30, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-05-15
Completion Report Received 2009-06-04
Correction to Well 2009-06-19 CORRECTION TO FOOTAGE INFORMATION: TARGET FOOTAGE= 1734'SL & 542'WL OF LOT 13; TARGET X= 2,233,577; TARGET Y= 609,765; SURFACE FOOTAGE= 1293'SL & 368'WL OF LOT 13; SURFACE X= 2,253,147; SURFACE Y= 609,935.
Construction Permit Expires 2010-04-10
Change of Owner 2015-05-12 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-09-22 3434 3475 36
3434 3475 36
3434 3475 36

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2000 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 M & M ROYALTY LTD 3144.00 5076.00 154
2010 M & M ROYALTY LTD 16732.00 5088.00 365
2011 M & M ROYALTY LTD 9338.00 2832.00 365
2012 M & M ROYALTY LTD 7368.00 1472.00 366
2013 M & M ROYALTY LTD 4268.00 776.00 365
2014 M & M ROYALTY LTD 3457.00 659.00 365
2015 SOUND ENERGY CO INC 1360.00 120.00 305
2016 SOUND ENERGY CO INC 1529.00 431.00 365
2017 SOUND ENERGY CO INC 1162.00 328.00 365
2018 SOUND ENERGY CO INC 957.00 210.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 M & M ROYALTY LTD Brine 605 154
2010 M & M ROYALTY LTD Brine 135 365
2011 M & M ROYALTY LTD Brine 114 365
2012 M & M ROYALTY LTD Brine 172 366
2013 M & M ROYALTY LTD Brine 66 365
2014 M & M ROYALTY LTD Brine 45 365
2015 SOUND ENERGY CO INC Brine 0 305
2016 SOUND ENERGY CO INC Brine 66 365
2017 SOUND ENERGY CO INC Brine 103 365
2018 SOUND ENERGY CO INC Brine 88 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1605897601 2016-5-9 0:00:0 UP No Violations 1.00
-536752271 2014-4-16 0:00: UP No Violations
-541242362 2015-3-24 0:00: UP No Violations 0.50
-669958826 2011-8-2 0:00:0 UL No Violations 0.50
0362212506 2017-07-06 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and associated batery are located on an otheriwse undeveloped parcel at the corner of Karen Lynn and Mill Rd.. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate chain-link enclosures. Enclosure gates were locked. Load-line valves were plugged, locked and secure. Fittings and connections at the wellhead and battery were secure and free from signs of leakage. The secondary containment was intact.
0536752271 2014-04-16 UrbanProduction Wells No Violations The producing unit is comprised of a pump jack and aboveground storage tank (AST) battery in separate chain-link enclosures. The enclosures are locked. Signage and ID is present and in good condition. There is secondary containment at the wellhead and battery. The well is producing with no signs of leakage or problems. The battery is comprised of 1 steel 100-barrel production tank and 1 steel 100-barrel brine tank, and separator unit. Process safety equipment is present. The dike is free of oil. The load-outs are locked and are fitted with secondary containment. The access drive has a cement apron, and surrounding areas are well maintained and runoff appears to be well managed. I noted that the gate valve for the dike drain in broken, leaving it free to drain to the adjacent creek. I contacted well tender Bob Allen about it, and he indicated repairs would be made today.
0541242362 2015-03-24 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and tank battery are located in separate chain-link enclosures at the SW corner of W. Mill and Karen Lynn. The wellhead pump jack and battery enclosure gates are secure and locked. Load-outs are plugged and secure. The containment interior is dry. Connections and fittings are secure and free from signs of leakage or problems.
0669958826 2011-08-02 UrbanPreliminary Restoration No Violations Urban Preliminary Restoration check due. Restoration Passed.
0857854878 2015-06-19 UrbanProduction Wells No Violations I instead this producing well as part of routine inspection activity. The well and battery are located at the corner of W. Mill and Karen Lynn, on an otherwise undeveloped parcel. Access to the well is afforded by a short, concrete-paved access road which enters from Karen Lynne. At the time of this inspection, I observed the following: enclosure gates are locked and secure. Tank hatch lids are closed and sealed. Load lines are lock-protected and secure. The electrical box is locked. Fittings and connections at the wellhead and battery are secure and free from signs of leakage. Process safety equipment is present. The secondary containment is intact and free of staining. The ID signage is not accurate and not compliant with OAC 1501:9-9-05(E)(1)(a-e). The 8.62-inch casing annulus is not plumbed to surface and gauged as required by a condition of the permit. I notified the well owner about these deficiencies. The owner has reported that new signs are being prepared.
1245848071 2009-05-04 Drill / Deepen / Reopen No Violations Making location , meets permit condition, NO Violation
1383753156 2013-11-06 UrbanPreliminary Restoration No Violations Unit is comprised of a pump jack and aboveground storage tank (AST) battery. The pump jack and battery are located in separate chain-link enclosures which are locked. The battery consists of 2 140-barrel production tanks and 2 140-barrel brine tanks, separator, and Dominion metering run. Secondary containment, signage and spacing are in compliance. The unit is producing and no problems observed.
1605897601 2016-05-09 UrbanProduction Wells No Violations I inspected this well location pursuant to a complaint (5318) of possible impact to a domestic water well located within 1/4 mile of this location. At the time of this inspection, I observed the following. A wellhead with pump jack system and tank battery is separate chain-link enclosures which were locked and secure. The fittings and connections at the wellhead and battery were secure. Load-lines were plugged, secure, and locked. Tank lids were closed and secure. (signage, surface casing, and lock on electrical box). Secondary containment was intact at the battery. The drain was closed. I walked the area surrounding the wellhead and battery and did not observe any signs of leakage, impact, or problems associated with the well. I noted that the surface casing nipple was not exposed and open or gauged as required by permit condition. I contacted Bruce Levengood with Sound Energy and advised him about the surface casing permit condition requirement. He indicated the condition would be corrected within 48 hours. I met with well tender Bob Allen at the location the following day, and the casing was property plumbed to surface.
362212506 2017-7-6 0:00:0 UP No Violations 0.50
857854878 2015-6-19 0:00: UP No Violations