34-035-22101

Well Details

Well ID: 34-035-22101
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: K & D GATES MILLS TOWER UNIT
License Status: Producing
License Date: 2009-01-20
Spud Date: 2009-03-16
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2009-03-22
Well Total Depth: 3580.00 ft
Configuration: Vertical
Latitude: 41.520000
Longitude: -81.430000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-01-20 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:1/20/2009, Expired Date:1/20/2010 6:00:00 AM, Drilling unit acres:28.03, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-03-22

-

Completion Report Received 2009-07-15

-

Construction Permit Expires 2010-01-20

-

Record Last Modified 2017-02-15

-

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-10-14 3393 3413 28
3393 3413 28
3393 3413 28

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 70001 Gal 41200

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 BASS ENERGY CO INC 9772.00 312.00 161
2010 BASS ENERGY CO INC 35257.00 399.00 365
2011 BASS ENERGY CO INC 15671.00 91.00 0
2012 BASS ENERGY CO INC 8315.00 42.00 366
2013 BASS ENERGY CO INC 7248.00 146.00 365
2014 BASS ENERGY CO INC 6009.00 74.00 365
2015 BASS ENERGY CO INC 5570.00 70.00 365
2016 BASS ENERGY CO INC 3895.00 0.00 365
2017 BASS ENERGY CO INC 3719.00 69.00 365
2018 BASS ENERGY CO INC 3575.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 BASS ENERGY CO INC Brine 210 161
2010 BASS ENERGY CO INC Brine 144 365
2011 BASS ENERGY CO INC Brine 49
2012 BASS ENERGY CO INC Brine 0 366
2013 BASS ENERGY CO INC Brine 80 365
2014 BASS ENERGY CO INC Brine 20 365
2015 BASS ENERGY CO INC Brine 32 365
2016 BASS ENERGY CO INC Brine 0 365
2017 BASS ENERGY CO INC Brine 0 365
2018 BASS ENERGY CO INC Brine 30 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1633819230 2009-3-16 0:00: DD No Violations
-756686655 2009-9-23 0:00: PL No Violations
-808917043 2009-10-28 0:00 PL No Violations
-950741874 2011-1-4 0:00:0 UP No Violations
0168239769 2015-02-27 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located in parking lot of the high-rise apartments at the referenced address. Access to the well is via the paved driveway which accesses the apartment facility . The wellhead plunger lift and battery are in separate board-on-board enclosures which are locked. The wellhead is comprised of 1 100-barrel steel lowboy production tank and 1 50-barrel steel lowboy brine tank, separator and Dominion metering run. Fittings and connections are secure and free from signs of leakage or problems. The load-outs are secure, plugged, and locked. Process safety gear is present. Signage is in place and current. At the time of this inspection there are 15 to 20 inches of snow cover in the area which obscures some surficial elements from observation.
0756686655 2009-09-23 Preliminary Restoration No Violations
0785906117 2009-03-16 Drill / Deepen / Reopen No Violations site inspection for HB permit condition
0804898476 2009-03-26 Drill / Deepen / Reopen No Violations running bond log good bond on 4.5
0808917043 2009-10-28 Preliminary Restoration No Violations no violation.
0950741874 2011-01-04 UrbanProduction Wells No Violations no violation.
1343497950 2017-10-10 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift and associated tank battery located in the parking area for the adjacent high-rise apartments. At the time of this inspection, I observed the following: The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery, and found no signs of impact or degradation attributable to the production system.
1633819230 2009-03-16 Drill / Deepen / Reopen No Violations on site for conductor cementing
168239769 2015-2-27 0:00: UP No Violations 0.50
1915244571 2013-01-08 UrbanProduction Wells No Violations The producing unit is comprised of a two-tank battery (2 140-barrel, 1 20-barrel) with mechanical separator and wellhead valve assembly. The tank battery is enclosed in an 8-foot board-on-board enclosure. The well is fitted with mechanical plunger lift in a separate enclosure which is locked and is currently producting. The secondary containment consists of a concrete dike. Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination.
2005022943 2016-10-11 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: The well was comprised of a mechanical plunger-lift system in a board-on-board enclosure. The enclosure gate was locked and secure. Fittings and connections at the wellhead were secure and free from signs of lekage. The tank battery was comprised of one 100-barrel low boy steel production tank, one 50-barrel steel brine tank, horizontal mechanical separator, and associated valve and tubular appurtenances. There were no signs or indications of problems or leakage. Load-line valves were locked and secure. Secondary containment was comprised of a poured-in-place cement berm which was intact. The areas surrounding the well conisst generally of asphalt-paved drive and parking areas, and I did not observe any signs or evidence of problems or environmental degradation.
2089871739 2009-03-17 Drill / Deepen / Reopen No Violations on site for surface cementing
785906117 2009-3-16 0:00: DD No Violations
804898476 2009-3-26 0:00: DD No Violations

For data sources see[9]