Well Details

Well ID: 34-035-22094
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PEP DRILLING LLC
Well Pad ID:
Farm/Lease Name: TEMPLE TIFFERETH
License Status: Producing
License Date: 2008-12-15
Spud Date: 2009-01-07
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 2009-01-23
Well Total Depth: 3766.00 ft
Configuration: Vertical
Latitude: 41.470000
Longitude: -81.490000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-12-15 Proposed Formations:CLINTON, Issued Date:12/15/2008, Expired Date:12/15/2009 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:EOUT
Reached Total Depth 2009-01-23
Completion Report Received 2009-08-17
Construction Permit Expires 2009-12-15
Change of Owner 2016-03-04 Operator changed from 1198, PIPES PURSIE E to 9640, PEP DRILLING LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-08-24 3578 3608 74
3578 3608 74
3578 3608 74

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 3595 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 PIPES PURSIE E 2245.00 242.00 163
2010 PIPES PURSIE E 15703.00 927.00 365
2011 PIPES PURSIE E 10871.00 519.00 365
2012 PIPES PURSIE E 10187.00 308.00 366
2013 PIPES PURSIE E 7691.00 294.00 365
2014 PIPES PURSIE E 8108.00 422.00 365
2016 PEP DRILLING LLC 6218.00 107.00 365
2017 PEP DRILLING LLC 2791.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 PIPES PURSIE E Brine 765 163
2010 PIPES PURSIE E Brine 899 365
2011 PIPES PURSIE E Brine 378 365
2012 PIPES PURSIE E Brine 319 366
2013 PIPES PURSIE E Brine 233 365
2014 PIPES PURSIE E Brine 259 365
2016 PEP DRILLING LLC Brine 0 365
2017 PEP DRILLING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1304533665 2012-1-12 0:00: UL No Violations 1.00
-232103012 2020-3-26 0:00: UP No Violations 2.50
-279237703 2009-4-22 0:00: DD No Violations
-795147088 2009-1-12 0:00: DD No Violations
0001701986 2009-01-07 Drill / Deepen / Reopen No Violations Rigging up to drill Conductor hole.
0010647445 2009-01-08 Drill / Deepen / Reopen No Violations cementing conductor
0271368747 2009-01-05 Drill / Deepen / Reopen No Violations Rig moving on site police directing traffic street sweeper on site if needed.
0279237703 2009-04-22 Drill / Deepen / Reopen No Violations well to be fracturing on Thursday.
0795147088 2009-01-12 Drill / Deepen / Reopen No Violations rig shut down because of weather
10647445 2009-1-8 0:00:0 DD No Violations
1235411100 2009-01-07 Drill / Deepen / Reopen No Violations Rig move on to site no violation at time of inspection.
1254994492 2015-03-09 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. Access to the well and battery is via the paved entry to the Temple Tiffereth on Shaker Blvd. The wellhead plunger lift and battery are in separate board-on-board enclosures. The battery is comprised of 2 100-barre;l steel tanks (1 production, 1 brine), a mechanical separator and Dominion metering run. At the time of my inspection, the enclosure gates are locked, load-outs are plugged, secure, and locked, and connections and fittings are secure and free from signs of leakage or other problems. Signage is present and current. At the time of this inspection, the surrounding areas are snow-covered. I did not observe any signs of impact relating to the on-going production activity at the time of this inspection.
1260190948 2009-10-14 Production Wells No Violations check for compliance of hb278 no violation
1304533665 2012-01-12 UrbanPreliminary Restoration No Violations On 01/12/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
1350774505 2009-01-22 Drill / Deepen / Reopen No Violations drilling 3660 no violation
1573650753 2019-10-31 0:00 UP No Violations 0.30
1701986 2009-1-7 0:00:0 DD No Violations
1861367040 2017-08-10 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate board-on-board enclosures. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of tall grasses and other vegetation, with a short, gravel-paved access road. I did not observe any signs of problems.
2091145725 2009-01-23 Drill / Deepen / Reopen No Violations 4.5 casting cementing
271368747 2009-1-5 0:00:0 DD No Violations

For data sources see[9]