34-035-22092

Well Details

Well ID: 34-035-22092
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: GLATZER
License Status: Producing
License Date: 2008-12-08
Spud Date: 2009-03-24
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2009-03-27
Well Total Depth: 3646.00 ft
Configuration: Vertical
Latitude: 41.330000
Longitude: -81.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-12-08 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:12/8/2008, Expired Date:12/8/2009 6:00:00 AM, Drilling unit acres:20.31, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-03-27
Completion Report Received 2009-06-17
Construction Permit Expires 2009-12-08
Correction to Well 2010-09-17 UNIT SIZE INCREASED TO 20.76 ACRES.
Correction to Well 2012-08-02 UNIT SIZE DECREASED TO 20.49 ACRES.
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-09-22 3392 3415 54
3392 3415 54
3392 3415 54

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2167 Bbl 60000 1000 GALLONS IC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 OHIO VALLEY ENERGY SYSTEMS COR 2023.00 3584.00 80
2010 OHIO VALLEY ENERGY SYSTEMS COR 19608.00 7705.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 18486.00 4401.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 9585.00 2573.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 6008.00 1336.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 3733.00 630.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 2155.00 401.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 1780.00 254.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 1307.00 308.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 972.00 307.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 2373 80
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 298 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 118 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 179 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 160 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 422 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 138 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 118 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 80 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2031305534 2014-9-22 0:00: UP No Violations
-945177517 2009-9-28 0:00: PL No Violations
0261545722 2010-01-22 Production Wells No Violations No violations !
0388677879 2009-04-02 Drill / Deepen / Reopen No Violations pits closed and covered
0945177517 2009-09-28 Preliminary Restoration No Violations checking tank battery company adding another oil storage tank. (preliminary restoration passed)
1012369232 2013-10-10 UrbanProduction Wells No Violations The producing wellhead includes a pump jack in a 8 board-on-board enclosure. The aboveground storage tank (AST) battery, which is shared with the Glatzer 2D unit, has been expanded to include a total of 2 100-barrel steel production tanks, 2 25-barrel poly brine tanks, 2 separators and a metering run. The battery is enclosed in an 8 board-on-board fence. The gates are locked. Spacing, unit ID signage, and secondary containment are good. Areas disturbed during drilling, including pits, have been filled, re-graded and seeded. The short access road to the wellhead has been graveled. Process safety equipment (spark arrestor, low-pressure relief valve, and carbon filter element) is present. No problems observed.
1238764542 2009-03-26 Drill / Deepen / Reopen No Violations Wildcat is drilling ahead. The pits are lined and in good condition and a tarp is covering the end of the blow line.
1369844340 2013-05-28 UrbanProduction Wells No Violations The producing unit consists of the following elements: a wellhead with pumpjack in a board-on-board enclosure, and a tank battery system also in a board-on-board enclosure. The enclosures are secured with locks and in in good condition. The tank battery is comprised of two 100-barrel steel tanks, a 25-barrel poly tank, and mechanical separator. HB 278 safety equipment is in place. I did observe the pressure lid on one of the production tanks was open and gas was escaping. I spoke with Ted Hill of Ohio Valley Energy and he indicated that he would fix it immediately. I did not observe any other problems or violations.
1679730291 2009-04-06 Drill / Deepen / Reopen No Violations working on location
2031305534 2014-09-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. There is currently a wellhead with pump jack and tank battery which shared with the Glatzer 2D. I observed oil leaking from a pressure relief fitting at the pump jack and some oily impact from leaking fittings in the tank battery. I contacted Rick Liddle with Ohio Valley Energy and advised him of the need for mechanical attention and clean-up of oil at the battery and wellhead. He indicated crews will be tending to these issues within the week.
261545722 2010-1-22 0:00: PW No Violations
388677879 2009-4-2 0:00:0 DD No Violations

For data sources see[9]

References