X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22042

Well Details

Well ID: 34-035-22042
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: SZUCH UNIT
License Status: Producing
License Date: 2015-06-24
Spud Date: 2008-07-22
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2008-07-25
Well Total Depth: 3589.00 ft
Configuration: Vertical
Latitude: 41.340000
Longitude: -81.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-06-02 Proposed Formations:ORISKANY/NEWBURG/CLINTON, Issued Date:6/2/2008, Expired Date:6/2/2009 6:00:00 AM, Drilling unit acres:21.86, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-07-25
Completion Report Received 2008-09-03
Correction to Well 2008-10-10 INCREASE UNIT SIZE TO 41.86 ACRES.
Correction to Well 2010-10-15 UNIT SIZE DECREASED TO 41.23 ACRES.
APP 2015-06-24 Proposed Formations:CLINTON, Issued Date:6/24/2015, Expired Date:6/23/2017 12:00:00 PM, Drilling unit acres:41.86, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2017-06-23
Change of Owner 2018-08-21 Operator changed from 3434, GONZOIL INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2018-08-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-10-20 3397 3459 22
3397 3459 22
3397 3459 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 66000 Gal 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 GONZOIL INC 23310.00 1484.00 365
2010 GONZOIL INC 10280.00 618.00 365
2011 GONZOIL INC 4038.00 556.00 365
2012 GONZOIL INC 4436.00 586.00 366
2013 GONZOIL INC 5722.00 282.00 365
2014 GONZOIL INC 2255.00 219.00 365
2015 GONZOIL INC 1740.00 55.00 365
2016 GONZOIL INC 1052.00 52.00 365
2017 GONZOIL INC 1064.00 124.00 365
2018 GONZOIL INC 768.00 0.00 180

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 GONZOIL INC Brine 502 365
2010 GONZOIL INC Brine 261 365
2011 GONZOIL INC Brine 147 365
2012 GONZOIL INC Brine 131 366
2013 GONZOIL INC Brine 176 365
2014 GONZOIL INC Brine 222 365
2015 GONZOIL INC Brine 68 365
2016 GONZOIL INC Brine 36 365
2017 GONZOIL INC Brine 35 365
2018 GONZOIL INC Brine 0 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1221507842 2013-4-3 0:00:0 UP No Violations
-442159073 2008-7-16 0:00: DD No Violations
-477896306 2008-5-21 0:00: DD No Violations
-904264978 2008-7-22 0:00: DD No Violations
0442159073 2008-07-16 Drill / Deepen / Reopen No Violations site construction
0477896306 2008-05-21 Drill / Deepen / Reopen No Violations site inspection
0741365427 2017-08-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection. The wellhead and battery are located in a wooded area behind a single-family home. Enclosure gates were locked and secure. ID signage was present and complete. The production tank hatches were closed and secure. The battery is shared with the Szuch #2 unit. At my previous inspection, I had noted the following: the electrical box was unlocked and not nsecure. There was oil staining around the back-pressure valve at the wellhead. At the time of this inspection, the maintenance issues had been addressed.
0904264978 2008-07-22 Drill / Deepen / Reopen No Violations site made rig moving on
1170862753 2011-10-25 UrbanProduction Wells No Violations Urban Production Well status check. Well is in compliance.
1221507842 2013-04-03 UrbanProduction Wells No Violations The producing unit consists of the following elements: a production wellhead and a storage tank battery. The production wellhead is fitted with a pumpjack system and is currently producing. The annular space is plumbed back to the production line. The pumpjack unit is enclosed in an 8-foot chainlink enclosure which is locked. The tank battery consists of 2 100-barrel steel tanks, 1 25-barrel poly tank, and a separator unit. The battery is enclosed in a chainlink enclosure. The secondary containment is present and in good condition. The tank battery is shared with the Szuch 2 Unit. No violations noted.
1319650567 2011-10-26 Production Wells No Violations Received call from Doug Gonzalez of Gonzoil concerning oil odor in air around wellhead. Met Doug at well, as well as Rick Reeve of Gonzoil. The Fire Chief from Broadview Heights was also on scene, due to call from nearby residence. Enviro Box (drip tank) failed to shut off when full, pumping oil into well head containment area. Estimated less than five gallons of oil released. Well owner employees cleaned up spill area using absorbent pads and spread peatsorb over the impacted area to soak up residual oil. I checked the site at approximately 3:30 PM and found no further leakage. The well owner will replace the enviro bottle and/or the automatic switch later today.
1659328663 2010-07-09 Preliminary Restoration No Violations
2135405236 2015-06-04 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection. The wellhead and battery are located in a wooded area behind a single-family home. Access to the wellhead is via the shared driveway which continues for an additional 1,000 feet to the wellhead. Enclosure gates are locked and secure. ID signage is present and complete. Process safety gear is present. The production tank hatches are secure. The battery is shared with the Szuch #2 unit. At the time of this inspection I observed the following items requiring maintenance: The electrical box is unlocked and unsecure. There is oil staining around back-pressure (Baird) valve which requires clean-up. I have notified the well owner that these maintenance issues must be remedied as soon as practicable or by 06/19/2015.
741365427 2017-8-22 0:00: UP No Violations 0.50

For data sources see[9]

References