If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22036 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.36,"lon":-81.41,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: BAAY OIL LLC | |
Well Pad ID: | |
Farm/Lease Name: ROSTANKOWSKI | |
License Status: Plugged and Abandoned | |
License Date: 2018-04-16 | |
Spud Date: 2008-07-07 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2008-07-15 | |
Well Total Depth: 3889.00 ft | |
Configuration: Vertical | |
Latitude: 41.360000 | |
Longitude: -81.410000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-04-23 | Proposed Formations:CLINTON, Issued Date:4/23/2008, Expired Date:4/23/2009 6:00:00 AM, Drilling unit acres:20.07, Proposed Well Type:OG, Proposed Well Class:POOL |
Correction to Well | 2008-05-30 | ADDED FOOTAGE: 885'SL & 1338'WL OF LOT 13, TRACT 3. |
Reached Total Depth | 2008-07-15 | UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT |
Completion Report Received | 2009-02-09 | UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT |
Change of Owner | 2016-01-29 | Operator changed from 1304, SEAGULL DEVELOPMENT CORP to 8560, BAAY OIL LLC |
APP | 2018-04-16 | Proposed Formations:CLINTON, Issued Date:4/16/2018, Expired Date:4/15/2020 12:00:00 PM, Drilling unit acres:20.07, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2018-06-25 | UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT |
Record Last Modified | 2018-11-01 | UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT |
Construction Permit Expires | 2020-04-15 | UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-03-24 | 3673 | 3733 | 25 |
3673 | 3733 | 25 | |
3673 | 3733 | 25 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 38427 Gal | 25000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | SEAGULL DEVELOPMENT CORP | 90.00 | 40.00 | 63 |
2009 | SEAGULL DEVELOPMENT CORP | 3602.00 | 206.00 | 63 |
2010 | SEAGULL DEVELOPMENT CORP | 3397.00 | 50.00 | 365 |
2011 | SEAGULL DEVELOPMENT CORP | 2550.00 | 40.00 | 365 |
2012 | SEAGULL DEVELOPMENT CORP | 1103.00 | 38.00 | 366 |
2013 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2014 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2015 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2016 | BAAY OIL LLC | 0.00 | 0.00 | 30 |
2017 | BAAY OIL LLC | 0.00 | 0.00 | 0 |
2018 | BAAY OIL LLC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | SEAGULL DEVELOPMENT CORP | Brine | 1245 | 63 |
2009 | SEAGULL DEVELOPMENT CORP | Brine | 0 | 63 |
2010 | SEAGULL DEVELOPMENT CORP | Brine | 1218 | 365 |
2011 | SEAGULL DEVELOPMENT CORP | Brine | 893 | 365 |
2012 | SEAGULL DEVELOPMENT CORP | Brine | 507 | 366 |
2013 | SEAGULL DEVELOPMENT CORP | Brine | 0 | 365 |
2014 | SEAGULL DEVELOPMENT CORP | Brine | 0 | 365 |
2015 | SEAGULL DEVELOPMENT CORP | Brine | 0 | 365 |
2016 | BAAY OIL LLC | Brine | 0 | 30 |
2017 | BAAY OIL LLC | Brine | 0 | 0 |
2018 | BAAY OIL LLC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1056527155 | 2010-2-2 0:00:0 | PW | No Violations | |
-1218144714 | 2016-2-4 0:00:0 | UP | No Violations | 1.00 |
-1623955796 | 2017-4-12 0:00: | UP | No Violations | |
-1758237164 | 2016-10-11 0:00 | AM | No Violations | 1.00 |
-2107981463 | 2008-7-7 0:00:0 | DD | No Violations | |
-224526410 | 2011-3-2 0:00:0 | UP | No Violations | |
-877095818 | 2013-6-20 0:00: | UP | No Violations | |
0224526410 | 2011-03-02 | UrbanProduction Wells | No Violations | No Violations |
0470645038 | 2008-10-29 | Preliminary Restoration | No Violations | area being leveled |
0877095818 | 2013-06-20 | UrbanProduction Wells | No Violations | The producing unit consists of a production wellhead in a board-on-board enclosure and an above-ground storage tank (AST) battery also in a board-on-board enclosure. The battery is comprised of 1 100-barrel steel AST, 50- barrel poly AST, mechanical separator, and metering run. Enclosure gates are locked and ID is in accordance with 1501:09. Secondary containment and HB 278 equipment is present at the battery. The wellhead is fitted with a mechanical plunger lift system and is producing. I did not observe any leaks or problems. |
1056527155 | 2010-02-02 | Production Wells | No Violations | No violation. |
1218144714 | 2016-02-04 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: Ingress and egress to and from the well area is afforded by the shared house driveway with short, unpaved section that extends north to the wellhead and battery. A wellhead with mechanical plunger lift system is located in a board-on-board enclosure in an opening within an otherwise wooded back yard area. The well enclosure is missing one of the sidewalls. Fittings and connections at the wellhead secure and free from leakage. The 8.625-inch casing annulus was exposed and plumbed into the system. Areas around the wellhead consist of turf grass and woods which were free from signs of stress or impact. The tank battery is located 50 feet west of the wellhead within the same grassy and wooded yard area. The battery is comprised of one 100-barrel, steel production tank, one 50-barrel poly brine tank. At the time of this inspection, the access gate to the battery was locked and secure. Signage was present. Fittings and connections were secure and free from signs of leakage or problems. Process safety gear and carbon filter system was present. Secondary containment was intact and dry. Tank lids are closed but the production tank lid is an older style flap-style lid which is not compliant with. The load-outs were plugged and locked. The battery and wellhead are located within a densely wooded area and not otherwise screened. I walked the area surrounding the battery and observed normal grassy vegetation with no signs of erosional deficits or impacts associated with the production operation. I did observe the following maintenance issues: the production tank lid must be replaced or upgraded to meet the sealing requirements of OAC 1501:9-9-05(E)(4)(d), the wellhead enclosure is partial broken down and needs repair. I notified the owner about the maintenance defficiencies. |
1232061469 | 2017-09-15 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: The well had been noted to be idle and fallen into a state of neglect. At the time of the issuance of the compliance notice, there had not been production reported for three consecutive years, and the owner was directed to plug and abandon the well . The wellhead enclosure fence was broken down, the interior of the battery had become overgrown with vegetation. Flow-line valves at the wellhead were closed. Since the compliance notice, the owner has submitted a production report for 2016 that indicates 216 MMC of gas production but no other indications that the well has been placed back into production. |
1463503772 | 2016-05-17 | UrbanProduction Wells | No Violations | I inspected this well pursuant to a complaint (#5330) by the surface land owner where this well is located. During a prior inspection, I noted that the production tank lid was not capable of sealing and needed upgraded, and the well enclosure was partially missing. I notified Baay Oil about the deficiencies at that time. At the time of this inspection, the well was comprised of a plunger lift and tank battery system with one 100-barrel steel production tank and 50-barrel poly tank. The well and battery were in separate board-on-board enclosures. The previously noted deficiencies had not been addressed. The well was shut-in with no production reported since 2012. The well owner/operator shall submit a written plugging schedule to Inspector Stephen Tompkins at ODNR Uniontown Field Office, 3575 Forest Lake Drive, Suite 150, Uniontown, OH 44685 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied. Contact Inspector Tompkins at 330-907-4647 with any questions regarding this Compliance Notice. |
1532449199 | 2018-06-25 | Plug / Plug Back | No Violations | I was on location to witness plugging and abandonment being performed by Hagen Well Service. Plugging and abandonment activity was completed with no obseved problems. The plug was stable at surface grade. Details of the plugging activity can be found in the associated plugging report. |
1623955796 | 2017-04-12 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to a previously-issued compliance notice. At the time of this inspection, the well was shut-in. Fittings and connections were secure. The wellhead fence enclosure was partially dismantled. I contacted Brooks Yarbrough with BAAY Oil who indicated that they are continuing efforts to return the well to production. |
1758237164 | 2016-10-11 | Administrative Inspection | No Violations | I contacted BAAY Oil, Inc. owner Brooks Yarbrough regarding this Compliance Notice. Mr. Yarbrough indicated that BAAY Oil intends to place this well back into production. He indicated a plan to begin activities towards this end within the next several weeks. |
2058639319 | 2008-07-23 | Drill / Deepen / Reopen | No Violations | having trouble getting sediments to drop out. |
2107981463 | 2008-07-07 | Drill / Deepen / Reopen | No Violations | rig moving on |
470645038 | 2008-10-29 0:00 | PL | No Violations |