If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22019 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.33,"lon":-81.67,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: PIN OAK ENERGY PARTNERS LLC | |
Well Pad ID: | |
Farm/Lease Name: BERMAN UNIT | |
License Status: Producing | |
License Date: 2007-12-28 | |
Spud Date: 2008-01-31 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2008-02-04 | |
Well Total Depth: 3551.00 ft | |
Configuration: Vertical | |
Latitude: 41.330000 | |
Longitude: -81.670000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-12-28 | Proposed Formations:CLINTON, Issued Date:12/28/2007, Expired Date:12/27/2008 6:00:00 AM, Drilling unit acres:20.78, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-02-04 | |
Completion Report Received | 2008-09-03 | |
Construction Permit Expires | 2008-12-27 | |
Correction to Well | 2010-07-30 | UNIT SIZE DECREASED 20.03 ACRES. |
Correction to Well | 2012-09-07 | UNIT SIZE INCREASED TO 20.46 ACRES. |
Change of Owner | 2018-08-21 | Operator changed from 3434, GONZOIL INC to 9722, PIN OAK ENERGY PARTNERS LLC |
Record Last Modified | 2018-08-21 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-10-17 | 3387 | 3422 | 21 |
3387 | 3422 | 21 | |
3387 | 3422 | 21 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 65000 Gal | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | GONZOIL INC | 4936.00 | 4160.00 | 184 |
2009 | GONZOIL INC | 18837.00 | 6935.00 | 365 |
2010 | GONZOIL INC | 13245.00 | 4427.00 | 365 |
2011 | GONZOIL INC | 9624.00 | 3211.00 | 365 |
2012 | GONZOIL INC | 6526.00 | 2232.00 | 366 |
2013 | GONZOIL INC | 3838.00 | 1720.00 | 365 |
2014 | GONZOIL INC | 2420.00 | 1193.00 | 365 |
2015 | GONZOIL INC | 1978.00 | 776.00 | 365 |
2016 | GONZOIL INC | 1847.00 | 637.00 | 365 |
2017 | GONZOIL INC | 1089.00 | 337.00 | 365 |
2018 | GONZOIL INC | 134.00 | 220.00 | 180 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | GONZOIL INC | Brine | 307 | 184 |
2009 | GONZOIL INC | Brine | 245 | 365 |
2010 | GONZOIL INC | Brine | 0 | 365 |
2011 | GONZOIL INC | Brine | 55 | 365 |
2012 | GONZOIL INC | Brine | 0 | 366 |
2013 | GONZOIL INC | Brine | 0 | 365 |
2014 | GONZOIL INC | Brine | 70 | 365 |
2015 | GONZOIL INC | Brine | 125 | 365 |
2016 | GONZOIL INC | Brine | 0 | 365 |
2017 | GONZOIL INC | Brine | 35 | 365 |
2018 | GONZOIL INC | Brine | 55 | 180 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1087450733 | 2008-2-1 0:00:0 | DD | No Violations | |
-1233542218 | 2008-5-15 0:00: | DD | No Violations | |
-1910696200 | 2013-10-3 0:00: | UP | No Violations | |
-2020773413 | 2008-1-30 0:00: | DD | No Violations | |
-2125926468 | 2008-2-6 0:00:0 | DD | No Violations | |
-517167891 | 2018-6-19 0:00: | UP | No Violations | 1.00 |
-820329053 | 2008-1-28 0:00: | DD | No Violations | |
0517167891 | 2018-06-19 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection. At the time of this inspection, the fittings and connections at the wellhead and battery were secure. I noted that the tank lids were closed and secure. Load-lines were locked and secure. The chart record was active. Production reports were current. Enclosure gates were locked. Tank lids were closed and secure. I walked the areas surrounding the well and battery and found normal conditions of the extant greenscape. |
0820329053 | 2008-01-28 | Drill / Deepen / Reopen | No Violations | Making location |
1087450733 | 2008-02-01 | Drill / Deepen / Reopen | No Violations | surface cementing |
1124874840 | 2014-12-12 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The wellhead and tank battery are located behind a single-family residence on Avery Rd. Fittings and connections at the linear rod pump and battery are secure and free from signs of leakage or problems. The interior of the secondary containment is clean and dry. Load-outs are plugged and gates are locked. Signage is present and the access road which extends east from the shared driveway is in good condition. |
1167761050 | 2008-01-31 | Drill / Deepen / Reopen | No Violations | Drilling 100 |
1233542218 | 2008-05-15 | Drill / Deepen / Reopen | No Violations | working on restoration ground real wet |
1704004945 | 2017-02-01 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. At the time of this inspection I observed the following: Access to the well and battery are afforded by an unpaved access road that extends beyond the paved driveway for the house. The access road and areas in and around the well were mostly snow covered, but were in good condition with no signs of erosional deficits or degradation. The production system was comprised of a pump jack and tank battery in separate board-on-board enclosures located in close proximity. The enclosure gates were closed and locked. The pump jack was in operation with no evidence of problems or leakage. I walked the interior of the tank battery enclosure and inspected the tanks and associated fittings, connections, and pipe runs. I did not observe any signs of leakage or spills. The tank load line valves were plugged and locked. The tank lids were closed. I walked the areas surrounding the wellhead and battery and found no evidence of impact or degradation. |
1910696200 | 2013-10-03 | UrbanProduction Wells | No Violations | The producing unit consists of a vertical piston unit at the wellhead and an aboveground storage tank (AST) battery. The battery is comprised of 2 140-barrel steel production tanks, a 50-barrel brine tank, and a separator unit. There is a Dominion metering run adjacent to the well. The elements are enclosed in separate board-on-board enclosures. There is adequate secondary containment. The signage is in good condition. Urban drilling process safety equipment is present. The load outs are locked and bull-plugged. |
2020773413 | 2008-01-30 | Drill / Deepen / Reopen | No Violations | Location made. |
2125926468 | 2008-02-06 | Drill / Deepen / Reopen | No Violations | pits being dewatered |
For data sources see[9]