X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21994

Well Details

Well ID: 34-035-21994
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PEP DRILLING LLC
Well Pad ID:
Farm/Lease Name: PROCHAZKA
License Status: Producing
License Date: 2007-08-23
Spud Date: 2007-08-29
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 2007-09-04
Well Total Depth: 3780.00 ft
Configuration: Vertical
Latitude: 41.450000
Longitude: -81.470000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-08-23 Proposed Formations:NEWBURG-ORISKANY-CLINTON, Issued Date:8/23/2007, Expired Date:8/22/2008 6:00:00 AM, Drilling unit acres:20.66, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-09-04
Completion Report Received 2008-02-21
Construction Permit Expires 2008-08-22
Change of Owner 2016-03-04 Operator changed from 1198, PIPES PURSIE E to 9640, PEP DRILLING LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-05-30 3618 3658 105
3618 3658 105
3618 3658 105

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2500 Bbl 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PIPES PURSIE E 10578.00 219.00 317
2009 PIPES PURSIE E 8788.00 80.00 365
2010 PIPES PURSIE E 9853.00 126.00 365
2011 PIPES PURSIE E 7202.00 0.00 365
2012 PIPES PURSIE E 3567.00 0.00 366
2013 PIPES PURSIE E 6600.00 117.00 365
2014 PIPES PURSIE E 5780.00 77.00 365
2016 PEP DRILLING LLC 5533.00 62.00 365
2017 PEP DRILLING LLC 3393.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PIPES PURSIE E Brine 948 317
2009 PIPES PURSIE E Brine 418 365
2010 PIPES PURSIE E Brine 381 365
2011 PIPES PURSIE E Brine 225 365
2012 PIPES PURSIE E Brine 0 366
2013 PIPES PURSIE E Brine 160 365
2014 PIPES PURSIE E Brine 95 365
2016 PEP DRILLING LLC Brine 0 365
2017 PEP DRILLING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1191966144 2007-10-10 0:00 DD No Violations
-2008874795 2007-10-19 0:00 DD No Violations
-351932019 2007-11-13 0:00 DD No Violations
0301611300 2009-11-12 Preliminary Restoration No Violations
0351932019 2007-11-13 Drill / Deepen / Reopen No Violations area graded no grass Tank battery set
1191966144 2007-10-10 Drill / Deepen / Reopen No Violations running tubing
1408374827 2014-08-18 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 09/04/2007. The unit is producing and production reports are current. The producing unit is accessed via a dedicated, gravel-paved access road which extends north from the terminus of the current residential driveway. The access road is level, and well drained with no signs of erosional deficits. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in board-on-board enclosures. The wellhead and surrounding area are free of signs of leaks or other impacts. Wellhead fittings and valve structure is intact and shows no signs of leaks or problems with corrosion or integrity. The battery is comprised of 1 steel 100-barrel production tank, 1 100-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead and are in good condition. No issues or problems requiring attention at the time of this inspection.
1414986793 2008-06-11 Drill / Deepen / Reopen No Violations well fenced working on tank battery
1476457840 2016-10-14 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the tank lids were not capable of sealing as required by OAC 1501:9-9-05(E)(4)(d). At the time of this inspection, the lids had been replaced and were in compliance. I inspected the rest of the production elements and observed the following: fittings and connections at the wellhead and battery were secure and free from leakage or problems. The secondary containment was intact and the interior was dry. The enclosure gates were locked and secure. The shared access road was in good condition.
1496163441 2017-05-30 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the tiem of this inspection, I observed the following: The wellhead and tank battery enclosures were locked and secure. Tank lids were closed and sealed. Load lines were closed, plugged, and secured with locks. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery which are comprised of meadow grasses and lightly wooded areas, and found no evidence of problems or impact to the surrounding greenscape attributable to the on-going production activity.
1921009941 2015-12-11 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. The well and associated tank battery are located in the back of a single-family residence. At the time of this inspection, the enclosure gates at the wellhead and battery were locked and secure. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. Areas around the wellhead and battery were comprised of grassy vegetation and wooded areas. I inspected the areas surrounding the wellhead and battery and did not observe any signs of problems or impacts. I observed the following maintenance deficiency: The production tank lids were old style hatch lids which do not seal and are not compliant with OAC 1501:9-9-05(E)(4)(d). The hatch lids must be replaced with lids with functioning seals. This safety deficiency must be addressed by 01/15/2016. Please contact Inspector Stephen Tompkins at 330-907-4647 regarding this inspection.
2008874795 2007-10-19 Drill / Deepen / Reopen No Violations meeting on site with operator
301611300 2009-11-12 0:00 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1921009941 US-OH-119310 2017-07-12 TANKS (a-i)

For data sources see[9]

References