X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21985

Well Details

Well ID: 34-035-21985
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: LAND PRESERVATION PARTNERS LLC
License Status: Producing
License Date: 2007-07-27
Spud Date: 2007-09-01
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-09-08
Well Total Depth:
Configuration: Vertical
Latitude: 41.480000
Longitude: -81.410000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-07-27 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:7/27/2007, Expired Date:7/26/2008 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-09-08
Completion Report Received 2008-07-11
Construction Permit Expires 2008-07-26
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-09-24 3457 3481 47
3457 3481 47
3457 3481 47

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 52082 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 BASS ENERGY CO INC 4249.00 1762.00 365
2009 BASS ENERGY CO INC 4284.00 1179.00 365
2010 BASS ENERGY CO INC 4400.00 1104.00 365
2011 BASS ENERGY CO INC 2575.00 554.00 0
2012 BASS ENERGY CO INC 2362.00 477.00 366
2013 BASS ENERGY CO INC 3274.00 853.00 365
2014 BASS ENERGY CO INC 2657.00 530.00 365
2015 BASS ENERGY CO INC 1288.00 304.00 365
2016 BASS ENERGY CO INC 1357.00 306.00 365
2017 BASS ENERGY CO INC 1029.00 267.00 365
2018 BASS ENERGY CO INC 1131.00 322.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 BASS ENERGY CO INC Brine 97 365
2009 BASS ENERGY CO INC Brine 20 365
2010 BASS ENERGY CO INC Brine 35 365
2011 BASS ENERGY CO INC Brine 0
2012 BASS ENERGY CO INC Brine 0 366
2013 BASS ENERGY CO INC Brine 0 365
2014 BASS ENERGY CO INC Brine 0 365
2015 BASS ENERGY CO INC Brine 25 365
2016 BASS ENERGY CO INC Brine 0 365
2017 BASS ENERGY CO INC Brine 0 365
2018 BASS ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0267798791 2017-10-10 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift and associated tank battery located on a larger residential parcel off of Fairmount Blvd. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery, and found no signs of impact or degradation attributable to the production system. The egress and ingress road was in good condition.
0628902146 2012-01-04 UrbanPreliminary Restoration No Violations On 01/04/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The off-set board-on-board fencing at the well head and tank battery are in good condition. Proper identification signs were posted on both the tank battery and well head fences. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
1382448319 2013-10-22 UrbanPreliminary Restoration No Violations The producing unit consists of a mechanical plunger lift unit and above-ground storage tank (AST) battery. The battery is comprised of 1 100-barrel steel production tank and 1 50-barrel brine tank, and separator unit. The wellhead is not enclosed. The battery is enclosed in a board-on-board fence. The load-outs are bull-plugged. The ID and secondary containment are good. The unit is fitted with carbon canister, low-pressure relief valve, and spark arrestor. Gates are locked. Lease road is in good condition and areas impacted by drilling have been restored. No problems noted and passes preliminary restoration.
1533654731 2018-08-07 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. I found the wellhead plunger lift and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems.
267798791 2017-10-10 0:00 UP No Violations 0.50
628902146 2012-1-4 0:00:0 UL No Violations 1.00

For data sources see[9]

References