34-035-21965

Well Details

Well ID: 34-035-21965
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: BURNS UNIT
License Status: Producing
License Date: 2007-03-21
Spud Date: 2007-10-17
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-10-23
Well Total Depth: 3459.00 ft
Configuration: Vertical
Latitude: 41.350000
Longitude: -81.640000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-03-21 Proposed Formations:CLINTON, Issued Date:3/21/2007, Expired Date:3/20/2008 6:00:00 AM, Drilling unit acres:20.8, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-10-23
Reached Total Depth 2007-10-23
Completion Report Received 2007-12-12
Construction Permit Expires 2008-03-20
Change of Owner 2015-05-12 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-02-21 3268 3323 57
3268 3323 57
3268 3323 57

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 M & M ROYALTY LTD 6203.00 1451.00 359
2009 M & M ROYALTY LTD 6843.00 636.00 365
2010 M & M ROYALTY LTD 4529.00 486.00 365
2011 M & M ROYALTY LTD 3099.00 438.00 365
2012 M & M ROYALTY LTD 2388.00 222.00 366
2013 M & M ROYALTY LTD 1817.00 437.00 365
2014 M & M ROYALTY LTD 710.00 113.00 365
2015 SOUND ENERGY CO INC 257.00 115.00 305
2016 SOUND ENERGY CO INC 843.00 221.00 365
2017 SOUND ENERGY CO INC 320.00 234.00 365
2018 SOUND ENERGY CO INC 103.00 230.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 M & M ROYALTY LTD Brine 540 359
2009 M & M ROYALTY LTD Brine 330 365
2010 M & M ROYALTY LTD Brine 265 365
2011 M & M ROYALTY LTD Brine 285 365
2012 M & M ROYALTY LTD Brine 137 366
2013 M & M ROYALTY LTD Brine 302 365
2014 M & M ROYALTY LTD Brine 0 365
2015 SOUND ENERGY CO INC Brine 0 305
2016 SOUND ENERGY CO INC Brine 705 365
2017 SOUND ENERGY CO INC Brine 91 365
2018 SOUND ENERGY CO INC Brine 113 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1243705099 2010-1-27 0:00: PW No Violations
-1791320036 2009-5-1 0:00:0 DD No Violations
-1977133491 2019-10-28 0:00 UP No Violations
-1991837899 2013-2-27 0:00: PL No Violations
-46080106 2008-10-28 0:00 PL No Violations
0046080106 2008-10-28 Preliminary Restoration No Violations
1243705099 2010-01-27 Production Wells No Violations No violations!
1327685858 2012-01-26 UrbanProduction Wells No Violations Mike Weinsz of M&M Royalty (well owner), contacted DNR Inspector Norburt Lowder on 1/25/2012 in reference a complaint from a resident living in the vicinity of this well. The resident stated that, since December 2011, there have been several tremors in the vicinity of her home and that these tremors move pictures on the wall and cause items to fall off of end tables in her home. She further stated that that several neighbors have experienced these tremors also. DNR Inspector Lowder referred this complaint to me, (Cuyahoga County DNR Inspector Ray Wallace). I met with Bob Allen, maintenance supervisor for M&M Royalty, at this well on Thursday, 01/26/2012, at 8:30 AM. We performed a status check inspection on this well which was operating at the time. No violations were found. At approximately 9:00 AM the well shut down. This well is set to run from 6:45 AM to 9:00 AM, Monday through Saturday. There was 240 pounds of pressure on both the 4.5 casing and the tubing. Shortly after 9:00 AM, I received a call from Mary Boehnlein, 6206 Timberlane Drive, Independence, Ohio who stated that she had experienced two tremors in the last five minutes. I assured her that neither Bob Allen or myself had experienced any tremors and that I didnt believe the well was the cause of the issue. I then contacted Paul Greco, Cuyahoga County ODNR Industrial Minerals Inspector, and asked him to help me in investigating this complaint. On Monday evening, January 30, 2012, I received a copy of an e-mail DNR Inspector Grecko sent to DNR Inspector Mike Mann, and several others, regarding this issue. A copy is in my complaint folder. This well is in compliance with 1501:09-5-5. No violations found. Complaint #3549 can be closed at the request of Inspector Paul Greco of mineral resources
1361349668 2015-06-16 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. Fittings and connections at the wellhead are secure. The enclosure gate is locked. Ingress and egress to and from the well and battery is afforded by the gravel-paved driveway which is shared with the referenced residence. The gates and enclosure at the battery are closed, locked, and secure. Load-outs are locked, bull plugged, and secure. Tank hatch lids are closed, sealed, and secure. Process safety equipment (spark arrestor, low-pressure relief valve, and carbon filter) is present. The secondary containment is intact and the drain is secure. The battery enclosure is equipped with two gates as required . The ID signage is missing. The electrical box at the wellhead requires a lock. There is gas leaking from a back-pressure fitting from the production casing. I will contact the owner/operator regarding the deficiencies.
1791090101 2017-10-06 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead pump jack system and associated tank battery located on a larger, residential parcel. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery which are comprised of open, grassy areas adjacent to a wooded portion, and found no signs of impact or degradation attributable to the production system.
1791320036 2009-05-01 Drill / Deepen / Reopen No Violations
1943536851 2007-10-16 Drill / Deepen / Reopen No Violations location made waiting on rig
1991837899 2013-02-27 Preliminary Restoration No Violations The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead consists of a pumpjack system in a 6 enclosure. The tank battery is comprised of 2 100-barrel (BBL) tanks, 1 50 BBL tank, mechanical separator, skid compressor unit, and associated piping and appurtenances enclosed in an 8 enclosure. The system is equipped with production safety equipment required by 1509:9-9-05. The loadout lines are locked and the secondary containment is good. I did not observe any leaks, releases, or problems. The unit ID cannot be seen from outside the enclosure. I spoke with Bob Allen and advised him about the need for adjustment of the sign location.

For data sources see[9]

References