If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-21953 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.53,"lon":-81.39,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Chester Township | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: LAND PRESERVATION PARTNERS | |
License Status: Plugged and Abandoned | |
License Date: 2017-10-30 | |
Spud Date: 2007-08-24 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2007-08-31 | |
Well Total Depth: 3655.00 ft | |
Configuration: Vertical | |
Latitude: 41.530000 | |
Longitude: -81.390000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-01-24 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:1/24/2007, Expired Date:1/24/2008 6:00:00 AM, Drilling unit acres:39.22, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2007-08-31 | UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT |
Completion Report Received | 2008-02-19 | UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT |
APP | 2017-10-30 | Proposed Formations:OHIO SHALE THROUGH CLINTON SAND, Issued Date:10/30/2017, Expired Date:10/30/2019 12:00:00 PM, Drilling unit acres:39.22, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2018-06-07 | UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT |
Record Last Modified | 2018-07-11 | UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT |
Construction Permit Expires | 2019-10-30 | UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-05-27 | 3480 | 3502 | 42 |
3480 | 3502 | 42 | |
3480 | 3502 | 42 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 52241 Gal | 30000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | BASS ENERGY CO INC | 21380.00 | 60.00 | 365 |
2009 | BASS ENERGY CO INC | 31715.00 | 57.00 | 365 |
2010 | BASS ENERGY CO INC | 24496.00 | 0.00 | 365 |
2011 | BASS ENERGY CO INC | 15091.00 | 74.00 | 0 |
2012 | BASS ENERGY CO INC | 9455.00 | 0.00 | 366 |
2013 | BASS ENERGY CO INC | 6286.00 | 0.00 | 365 |
2014 | BASS ENERGY CO INC | 4628.00 | 0.00 | 365 |
2015 | BASS ENERGY CO INC | 3789.00 | 0.00 | 365 |
2016 | BASS ENERGY CO INC | 3274.00 | 0.00 | 365 |
2017 | BASS ENERGY CO INC | 2023.00 | 0.00 | 365 |
2018 | BASS ENERGY CO INC | 37.00 | 30.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | BASS ENERGY CO INC | Brine | 20 | 365 |
2009 | BASS ENERGY CO INC | Brine | 136 | 365 |
2010 | BASS ENERGY CO INC | Brine | 210 | 365 |
2011 | BASS ENERGY CO INC | Brine | 87 | |
2012 | BASS ENERGY CO INC | Brine | 0 | 366 |
2013 | BASS ENERGY CO INC | Brine | 75 | 365 |
2014 | BASS ENERGY CO INC | Brine | 60 | 365 |
2015 | BASS ENERGY CO INC | Brine | 0 | 365 |
2016 | BASS ENERGY CO INC | Brine | 0 | 365 |
2017 | BASS ENERGY CO INC | Brine | 0 | 365 |
2018 | BASS ENERGY CO INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1237505375 | 2014-8-27 0:00: | UP | No Violations | |
-1353018975 | 2018-6-4 0:00:0 | PB | No Violations | 4.00 |
-1425379277 | 2008-5-20 0:00: | PW | No Violations | |
-294333100 | 2017-6-26 0:00: | UP | No Violations | 1.00 |
-438829592 | 2009-10-14 0:00 | DD | No Violations | |
-716804240 | 2018-6-7 0:00:0 | PB | No Violations | 4.00 |
0237322826 | 2010-11-02 | Preliminary Restoration | No Violations | |
0244643152 | 2014-03-21 | UrbanProduction Wells | No Violations | The producing unit is comprised of a wellhead with mechanical plunger lift unit and aboveground storage tank (AST) battery with 1 100-barrel production tank, 1 50-barrel brine tank, mechanical separator, and Dominion metering run. The battery and wellhead are in separate chain-link enclosures, with locks. The unit spacing, signage, process safety equipment are present and good. Secondary containment is present. The lease road is in good condition, and landscaping and shrub screening is in place at the battery. No problems or violations. |
0294333100 | 2017-06-26 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead and associated tank battery with dedicated access from County Line Road which was in good condition with some grassy over-growth but passable, and well drained with no erosional deficits or problems. The wellhead and tank battery enclosure gates were locked and secure. Fittings and connections at the wellhead and battery were secure. The tank lids were closed and secure. The secondary containment was dry and intact with no signs of spills, leaks, or other problems. I walked the areas around the wellhead and battery which was comprised of level meadow with tall grasses. I observed no signs of impact or problem. |
0438829592 | 2009-10-14 | Drill / Deepen / Reopen | No Violations | no violation |
0716804240 | 2018-06-07 | Plug / Plug Back | No Violations | I was on location to witness plugging and abandonment activity being conducted by Nicks Well Plugging. Details of these activities and observations can be found in the associated plugging report. |
0889339726 | 2018-06-05 | Plug / Plug Back | No Violations | I was on location to witness plugging and abandonment activity being conducted by Nicks Well Plugging. Details of these activities and observations can be found in the associated plugging report. |
1237505375 | 2014-08-27 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The well was completed in 08/31/2007. The unit is producing and production reports are current. The well is located in a upscale suburban area with large lots, and densely wooded areas around the well and battery. The producing unit is accessed via a dedicated gravel access road which enters off of County Line Road and heads west for 500 feet to the unit. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate chain-link enclosures. The valve fittings, connections, and other production appurtenances appear to be well maintained and are free from signs of leakage or other problems. The battery is comprised of 1 steel 140-barrel production tank, 1 50-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead and are in good condition. Evergreen and deciduous foliage screening is present and well established around the wellhead and battery. I observed no issues or problems requiring attention at the time of my inspection. |
1353018975 | 2018-06-04 | Plug / Plug Back | No Violations | I was on location to witness plugging and abandonment activity being conducted by Nicks Well Plugging under contract to Bass Energy. During my inspection, crews established a temporary pit, lined with plastic. The well was noted to be stable. A bottom formation plug was set through 1.5-inch tubing and shut-in overnight. The 4.5 casing was to be separated by Appalachian Well Service the following day (6/5/18). |
1388669323 | 2018-06-06 | Plug / Plug Back | No Violations | I was on location to witness plugging and abandonment activity being conducted by Nicks Well Plugging. Details of these activities and observations can be found in the associated plugging report. |
1425379277 | 2008-05-20 | Production Wells | No Violations | |
1431019709 | 2017-11-20 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The well and associated tank battery, are located on a rural parcel in a wooded area. At the time of this inspection, fittings and connections at the well and battery were secure and free from leakage or problems. The load-line valves were secure and locked. Tank lids were closed and secure. Secondary containment as intact and free from signs of release, leaks, or problems. The well was in active production. Production reports were current. Bonding and insurance were active and current. I walked and inspected the areas surrounding the wellhead and battery and found no evidence of impacts from leaks, releases, or degradation to the natural greenscape. |
1861599579 | 2011-03-10 | Production Wells | No Violations | Well location is in good repair. Dike is in good repair. No leaks around the wellhead noted. Lease road was stable. Lease road gate was locked. Operator has spill prevention devices on the load lines. Meter run is inside the tank battery dike. |
237322826 | 2010-11-2 0:00: | PL | No Violations | |
244643152 | 2014-3-21 0:00: | UP | No Violations | |
889339726 | 2018-6-5 0:00:0 | PB | No Violations | 8.00 |
For data sources see[9]