X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21953

Well Details

Well ID: 34-035-21953
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: LAND PRESERVATION PARTNERS
License Status: Plugged and Abandoned
License Date: 2017-10-30
Spud Date: 2007-08-24
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-08-31
Well Total Depth: 3655.00 ft
Configuration: Vertical
Latitude: 41.530000
Longitude: -81.390000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-01-24 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:1/24/2007, Expired Date:1/24/2008 6:00:00 AM, Drilling unit acres:39.22, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-08-31 UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT
Completion Report Received 2008-02-19 UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT
APP 2017-10-30 Proposed Formations:OHIO SHALE THROUGH CLINTON SAND, Issued Date:10/30/2017, Expired Date:10/30/2019 12:00:00 PM, Drilling unit acres:39.22, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2018-06-07 UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT
Record Last Modified 2018-07-11 UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT
Construction Permit Expires 2019-10-30 UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17. GMM UPDATED PLUG STATUS PER PLUG REPORT

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-05-27 3480 3502 42
3480 3502 42
3480 3502 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 52241 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 BASS ENERGY CO INC 21380.00 60.00 365
2009 BASS ENERGY CO INC 31715.00 57.00 365
2010 BASS ENERGY CO INC 24496.00 0.00 365
2011 BASS ENERGY CO INC 15091.00 74.00 0
2012 BASS ENERGY CO INC 9455.00 0.00 366
2013 BASS ENERGY CO INC 6286.00 0.00 365
2014 BASS ENERGY CO INC 4628.00 0.00 365
2015 BASS ENERGY CO INC 3789.00 0.00 365
2016 BASS ENERGY CO INC 3274.00 0.00 365
2017 BASS ENERGY CO INC 2023.00 0.00 365
2018 BASS ENERGY CO INC 37.00 30.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 BASS ENERGY CO INC Brine 20 365
2009 BASS ENERGY CO INC Brine 136 365
2010 BASS ENERGY CO INC Brine 210 365
2011 BASS ENERGY CO INC Brine 87
2012 BASS ENERGY CO INC Brine 0 366
2013 BASS ENERGY CO INC Brine 75 365
2014 BASS ENERGY CO INC Brine 60 365
2015 BASS ENERGY CO INC Brine 0 365
2016 BASS ENERGY CO INC Brine 0 365
2017 BASS ENERGY CO INC Brine 0 365
2018 BASS ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1237505375 2014-8-27 0:00: UP No Violations
-1353018975 2018-6-4 0:00:0 PB No Violations 4.00
-1425379277 2008-5-20 0:00: PW No Violations
-294333100 2017-6-26 0:00: UP No Violations 1.00
-438829592 2009-10-14 0:00 DD No Violations
-716804240 2018-6-7 0:00:0 PB No Violations 4.00
0237322826 2010-11-02 Preliminary Restoration No Violations
0244643152 2014-03-21 UrbanProduction Wells No Violations The producing unit is comprised of a wellhead with mechanical plunger lift unit and aboveground storage tank (AST) battery with 1 100-barrel production tank, 1 50-barrel brine tank, mechanical separator, and Dominion metering run. The battery and wellhead are in separate chain-link enclosures, with locks. The unit spacing, signage, process safety equipment are present and good. Secondary containment is present. The lease road is in good condition, and landscaping and shrub screening is in place at the battery. No problems or violations.
0294333100 2017-06-26 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead and associated tank battery with dedicated access from County Line Road which was in good condition with some grassy over-growth but passable, and well drained with no erosional deficits or problems. The wellhead and tank battery enclosure gates were locked and secure. Fittings and connections at the wellhead and battery were secure. The tank lids were closed and secure. The secondary containment was dry and intact with no signs of spills, leaks, or other problems. I walked the areas around the wellhead and battery which was comprised of level meadow with tall grasses. I observed no signs of impact or problem.
0438829592 2009-10-14 Drill / Deepen / Reopen No Violations no violation
0716804240 2018-06-07 Plug / Plug Back No Violations I was on location to witness plugging and abandonment activity being conducted by Nicks Well Plugging. Details of these activities and observations can be found in the associated plugging report.
0889339726 2018-06-05 Plug / Plug Back No Violations I was on location to witness plugging and abandonment activity being conducted by Nicks Well Plugging. Details of these activities and observations can be found in the associated plugging report.
1237505375 2014-08-27 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 08/31/2007. The unit is producing and production reports are current. The well is located in a upscale suburban area with large lots, and densely wooded areas around the well and battery. The producing unit is accessed via a dedicated gravel access road which enters off of County Line Road and heads west for 500 feet to the unit. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate chain-link enclosures. The valve fittings, connections, and other production appurtenances appear to be well maintained and are free from signs of leakage or other problems. The battery is comprised of 1 steel 140-barrel production tank, 1 50-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead and are in good condition. Evergreen and deciduous foliage screening is present and well established around the wellhead and battery. I observed no issues or problems requiring attention at the time of my inspection.
1353018975 2018-06-04 Plug / Plug Back No Violations I was on location to witness plugging and abandonment activity being conducted by Nicks Well Plugging under contract to Bass Energy. During my inspection, crews established a temporary pit, lined with plastic. The well was noted to be stable. A bottom formation plug was set through 1.5-inch tubing and shut-in overnight. The 4.5 casing was to be separated by Appalachian Well Service the following day (6/5/18).
1388669323 2018-06-06 Plug / Plug Back No Violations I was on location to witness plugging and abandonment activity being conducted by Nicks Well Plugging. Details of these activities and observations can be found in the associated plugging report.
1425379277 2008-05-20 Production Wells No Violations
1431019709 2017-11-20 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and associated tank battery, are located on a rural parcel in a wooded area. At the time of this inspection, fittings and connections at the well and battery were secure and free from leakage or problems. The load-line valves were secure and locked. Tank lids were closed and secure. Secondary containment as intact and free from signs of release, leaks, or problems. The well was in active production. Production reports were current. Bonding and insurance were active and current. I walked and inspected the areas surrounding the wellhead and battery and found no evidence of impacts from leaks, releases, or degradation to the natural greenscape.
1861599579 2011-03-10 Production Wells No Violations Well location is in good repair. Dike is in good repair. No leaks around the wellhead noted. Lease road was stable. Lease road gate was locked. Operator has spill prevention devices on the load lines. Meter run is inside the tank battery dike.
237322826 2010-11-2 0:00: PL No Violations
244643152 2014-3-21 0:00: UP No Violations
889339726 2018-6-5 0:00:0 PB No Violations 8.00

For data sources see[9]

References