Well ID: 34-035-21947
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: CLEVELAND OUTDOOR UNIT
License Status: Producing
License Date: 2007-01-10
Spud Date: 2007-01-12
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-01-17
Well Total Depth: 3580.00 ft
Configuration: Vertical
Latitude: 41.390000
Longitude: -81.510000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-01-10 Proposed Formations:CLINTON, Issued Date:1/10/2007, Expired Date:1/10/2008 6:00:00 AM, Drilling unit acres:24.28, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-01-17
Reached Total Depth 2007-01-17
Completion Report Received 2007-09-07
Construction Permit Expires 2008-01-10
Change of Owner 2015-07-06 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-12-04 3418 3474 42
3418 3474 42
3418 3474 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1600 Bbl 50000 FOR A GIVEN UNIT, THE DEPTH IS @ 36' DEEPER ON THE GR/CCL LOG THAN ON THE GR/N/D LOG; THIS ACCOUNTS FOR THE LACK OF CORRELATION BETWEEN THE UNIT DEPTHS ON PAGE 3 AND THE PERF INTERVAL ABOVE… GM 12/4/07

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 M & M ROYALTY LTD 2469.00 78.00 169
2008 M & M ROYALTY LTD 4986.00 139.00 365
2009 M & M ROYALTY LTD 1995.00 109.00 365
2010 M & M ROYALTY LTD 1930.00 100.00 365
2011 M & M ROYALTY LTD 1542.00 0.00 365
2012 M & M ROYALTY LTD 1302.00 60.00 366
2013 M & M ROYALTY LTD 1081.00 64.00 365
2014 M & M ROYALTY LTD 1048.00 0.00 365
2015 SOUND ENERGY CO INC 316.00 0.00 213
2016 SOUND ENERGY CO INC 853.00 0.00 365
2017 SOUND ENERGY CO INC 408.00 0.00 365
2018 SOUND ENERGY CO INC 599.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 M & M ROYALTY LTD Brine 80 169
2008 M & M ROYALTY LTD Brine 140 365
2009 M & M ROYALTY LTD Brine 140 365
2010 M & M ROYALTY LTD Brine 140 365
2011 M & M ROYALTY LTD Brine 0 365
2012 M & M ROYALTY LTD Brine 58 366
2013 M & M ROYALTY LTD Brine 0 365
2014 M & M ROYALTY LTD Brine 53 365
2015 SOUND ENERGY CO INC Brine 31 213
2016 SOUND ENERGY CO INC Brine 0 365
2017 SOUND ENERGY CO INC Brine 84 365
2018 SOUND ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-790614406 2007-1-16 0:00: DD No Violations
0288621821 2007-01-13 Drill / Deepen / Reopen No Violations srface
0509709841 2011-08-02 UrbanPreliminary Restoration No Violations No Violation.
0790614406 2007-01-16 Drill / Deepen / Reopen No Violations gas in newburg 2700 switched to fluid Dillinng at 3329 at time of inspection
1172084691 2007-01-11 Drill / Deepen / Reopen No Violations making location
1321460434 2011-08-02 Preliminary Restoration No Violations I inspected well site and found it in complance.
1375899866 2013-08-07 UrbanPreliminary Restoration No Violations The producing unit is comprised of a production wellhead with mechanical plunger-lift system which is currently producing. The wellhead has an identification placard. Identification is present at the tank battery. The tank battery is comprised of 2 100-barrel production above-ground storage tanks (ASTs) and one 20-barrel brine AST. The battery is fitted with spark arrestor, carbon filter, and low-pressure relief valve as required by 1501:9-9-05(E). There is secondary containment. The load-outs are bull-plugged and locked. The unit spacing meets requirements. I did not observe any problems or violations.
288621821 2007-1-13 0:00: DD No Violations
509709841 2011-8-2 0:00:0 UL No Violations

For data sources see[9]