Well Details

Well ID: 34-035-21935
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: CERINO UNIT
License Status: Producing
License Date: 2006-10-06
Spud Date: 2007-02-28
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-03-03
Well Total Depth: 3470.00 ft
Configuration: Vertical
Latitude: 41.340000
Longitude: -81.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-10-06 Proposed Formations:OHIO SHALE THUR CLINTON, Issued Date:10/6/2006, Expired Date:10/6/2007 6:00:00 AM, Drilling unit acres:22.12, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-03-03
Construction Permit Expires 2007-10-06
Completion Report Received 2008-02-19
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-05-27 3267 3287 22
3267 3287 22
3267 3287 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 51000 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 BASS ENERGY CO INC 4244.00 526.00 365
2009 BASS ENERGY CO INC 2613.00 472.00 365
2010 BASS ENERGY CO INC 1331.00 314.00 365
2011 BASS ENERGY CO INC 1178.00 171.00 0
2012 BASS ENERGY CO INC 911.00 276.00 366
2013 BASS ENERGY CO INC 1160.00 286.00 365
2014 BASS ENERGY CO INC 1002.00 237.00 365
2015 BASS ENERGY CO INC 653.00 177.00 365
2016 BASS ENERGY CO INC 943.00 250.00 365
2017 BASS ENERGY CO INC 1081.00 165.00 365
2018 BASS ENERGY CO INC 998.00 175.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 BASS ENERGY CO INC Brine 276 365
2009 BASS ENERGY CO INC Brine 530 365
2010 BASS ENERGY CO INC Brine 415 365
2011 BASS ENERGY CO INC Brine 362
2012 BASS ENERGY CO INC Brine 488 366
2013 BASS ENERGY CO INC Brine 425 365
2014 BASS ENERGY CO INC Brine 323 365
2015 BASS ENERGY CO INC Brine 219 365
2016 BASS ENERGY CO INC Brine 246 365
2017 BASS ENERGY CO INC Brine 201 365
2018 BASS ENERGY CO INC Brine 155 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1054458083 2015-5-22 0:00: UP No Violations
-659139668 2017-11-9 0:00: UP No Violations 0.50
-871933968 2019-4-30 0:00: PW No Violations
0200637015 2017-05-01 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery is separate chain-link enclosures located at the rear portion of a commercial facility . The enclosure gates were locked. Fittings and connections at both the wellhead and battery were secure. Load-line valves were plugged, locked and secure. The tank lids were closed and secure. Secondary containment was intact and the interior areas were dry and free from signs of leakage or problems. I walked and inspected the areas around the wellhead and battery and found no evidence of impact or environmental degradation relating to the on-going production activity.
0288771509 2007-03-05 Drill / Deepen / Reopen No Violations rig moving
0615804406 2007-10-03 Preliminary Restoration No Violations
0659139668 2017-11-09 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery is separate chain-link enclosures. The enclosure gates were locked. Fittings and connections at both the wellhead and battery were secure. Load-line valves were plugged, locked and secure. The well was in active production. The tank lids were closed and secure. Secondary containment was intact and the interior areas were dry and free from signs of leakage or problems. I walked and inspected the areas around the wellhead and battery and found no evidence of impact or environmental degradation relating to the on-going production activity.
0871933968 2019-04-30 Production Wells No Violations I conducted an inspection of this well and found no violation at well or tank battery.

The following issue need to be addressed:

1030852944 2007-03-12 Drill / Deepen / Reopen No Violations
1054458083 2015-05-22 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well is producing and production records are current. Entry gates are locked and secure, at both the wellhead and battery. Process safety equipment is present. Fittings and connections are secure and free from signs of leakage or problems. Tank hatches are closed and secure. At the time of this inspection, I observed the following deficiencies: ID signage is lacking required information. The evergreen screening required as part of site restoration is incomplete (missing on the south side of the wellhead). Warning signage is incomplete. I have notified Bass Energy that these deficiencies must be corrected as soon as practicable or by 06/29/2015. Please contact Inspector Stephen Tompkins at 330-907-4647 for questions regarding this inspection.
1154174908 2007-12-03 Preliminary Restoration No Violations
1382973021 2013-10-28 UrbanProduction Wells No Violations The producing unit consists of a wellhead with pump jack and above-ground storage tank (AST) battery. The battery is comprised of 1 140-barrel steel production tank, 1 50-barrel brine tank and separator unit. Both the wellhead and battery are enclosed in separate chain-link fences. The gates and load-outs are locked. ID placard and secondary containment are good. Process safety gear (spark arrestor, low-pressure relief valve, carbon filter) is present. No problems noted.
1475080654 2016-09-28 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system located in a screened, chain-link fence which was locked and secure. The fittings and connections at the wellhead were secure and free from signs of leakage or problems. The area around the wellhead consists of asphalt-paved parking for the restaurant that exists on the property. The associated tank battery is located along the southern-most limit of the parking lot, in a separate chain-link enclosure. Gates and load-lines were secure. Signage had been updated and was compliant. I walked the areas around both the wellhead and battery and did not observe any signs or evidence of environmental impact or degradation.
1838198818 2008-12-01 Production Wells No Violations no violation
200637015 2017-5-1 0:00:0 UP No Violations 0.50
2144473646 2015-01-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead pump jack enclosure is secure. Valves and connections are secure and free from signs of leakage or problems. At the time of my inspection, the area is covered with several inches of snow. Access to the well and battery is from the party center parking lot which is clear and snow has been plowed. Load-outs are bull-plugged and locked. I did not observe any problems at the time of this inspection.
288771509 2007-3-5 0:00:0 DD No Violations
615804406 2007-10-3 0:00: PL No Violations
896933227 2020-1-27 0:00: UP No Violations

For data sources see[9]