X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21921

Well Details

Well ID: 34-035-21921
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: J WELL SERVICE INC
Well Pad ID:
Farm/Lease Name: STENZEL
License Status: Producing
License Date: 2006-08-22
Spud Date: 2006-09-26
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2006-09-28
Well Total Depth: 3522.00 ft
Configuration: Vertical
Latitude: 41.320000
Longitude: -81.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-08-22 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:8/22/2006, Expired Date:8/22/2007 6:00:00 AM, Drilling unit acres:20.34, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-09-28
Reached Total Depth 2006-09-28
Completion Report Received 2007-03-23
Construction Permit Expires 2007-08-22
Change of Owner 2018-01-09 Operator changed from 2456, OHIO VALLEY ENERGY SYSTEM CORP to 8738, J WELL SERVICE INC
Record Last Modified 2018-01-09

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-06-29 3302 3326 42
3302 3326 42
3302 3326 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2214 Bbl 60000 500 GALLONS MCA & 500 GALLONS IC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 OHIO VALLEY ENERGY SYSTEMS COR 1109.00 169.00 173
2008 OHIO VALLEY ENERGY SYSTEMS COR 4707.00 104.00 365
2009 OHIO VALLEY ENERGY SYSTEMS COR 4561.00 98.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 4957.00 57.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 5148.00 101.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 3843.00 80.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 2817.00 67.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 1151.00 0.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 1011.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 193.00 0.00 238
2017 OHIO VALLEY ENERGY SYSTEMS COR 82.00 0.00 365
2018 J WELL SERVICE INC 4.00 0.00 60

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 OHIO VALLEY ENERGY SYSTEMS COR Brine 621 173
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 472 365
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 331 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 332 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 280 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 260 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 130 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 331 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 327 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 238
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 30

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1334114621 2013-11-6 0:00: UP No Violations
-278903483 2008-5-15 0:00: PL No Violations
0278903483 2008-05-15 Preliminary Restoration No Violations
1334114621 2013-11-06 UrbanProduction Wells No Violations Unit is comprised of a mechanical plunger lift and aboveground storage tank (AST) battery. The wellhead and battery are located in separate chain-link enclosures which are locked. The battery consists of 1 140-barrel production tank and 1 50-barrel brine tank, and separator. Secondary containment, signage and spacing are in compliance. The unit is producing and no problems observed.
1410449267 2017-12-19 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located on a rural residential parcel with a shared-use, gravel-paved access road/driveway. The access road was in a good condition and passable. The enclosure gates were locked. Load-lines were locked and secure. Tank lids were closed and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. The well was in production. There was an active chart record and production reports were current. I walked the areas surrounding the well and found no signs of problems or impacts relating to the production operation.
1803641680 2015-06-18 UrbanProduction Wells No Violations I instead this producing well as part of routine inspection activity. The well and battery are located in a clearing in a wooded parcel which is shared with a home Access to the well is afforded by a gravel-paved access road which enters from Harris Rd. and proceeds north to the house and wellhead. At the time of this inspection, I observed the following: enclosure gates are locked and secure. Tank hatch lids are closed and sealed. Load lines are lock-protected and secure. Fittings and connections at the wellhead and battery are secure and free from signs of leakage. Process safety equipment is present. The secondary containment is intact and free of standing water or staining. The shared entry road is well-drained and free from erosional deficits. The ID signage is not compliant with OAC 1501:9-9-05E(1)(a-e). I notified the well own regarding the ID signage. The owner has reported that new signs are being prepared.

For data sources see[9]

References