34-035-21915

Well Details

Well ID: 34-035-21915
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: J WELL SERVICE INC
Well Pad ID:
Farm/Lease Name: MATTES
License Status: Producing
License Date: 2006-07-27
Spud Date: 2006-09-20
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2006-09-22
Well Total Depth: 3621.00 ft
Configuration: Vertical
Latitude: 41.320000
Longitude: -81.710000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-07-27 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:7/27/2006, Expired Date:7/27/2007 6:00:00 AM, Drilling unit acres:23.16, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-09-22 RBDMS Rec
Reached Total Depth 2006-09-22 RBDMS Rec
Construction Permit Expires 2007-07-27 RBDMS Rec
Completion Report Received 2007-09-28 RBDMS Rec
Correction to Well 2012-02-10 UNIT SIZE REDUCED TO 20.55 ACRES.
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-12-31 3433 3443 40
3433 3443 40
3433 3443 40

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2215 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 OHIO VALLEY ENERGY SYSTEMS COR 654.00 0.00 23
2008 OHIO VALLEY ENERGY SYSTEMS COR 16584.00 119.00 314
2009 OHIO VALLEY ENERGY SYSTEMS COR 19997.00 161.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 18436.00 221.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 13968.00 61.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 8775.00 56.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 9577.00 35.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 4753.00 49.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 2581.00 52.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 805.00 39.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 332.00 0.00 151
2018 OHIO VALLEY ENERGY SYSTEMS COR 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 OHIO VALLEY ENERGY SYSTEMS COR Brine 75 23
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 690 314
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 410 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 446 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 352 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 322 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 573 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 256 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 33 151
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1918593260 2011-9-7 0:00:0 UP No Violations
-483092535 2018-6-21 0:00: UP No Violations 0.50
-614230607 2009-11-5 0:00: PL No Violations
-892994157 2015-1-29 0:00: UP No Violations 0.50
0483092535 2018-06-21 UrbanProduction Wells No Violations I inspected this well as part of routine inspection. Fittings and connections at the well and battery were secure and free from leakage or problems. The tank lids were closed. The secondary containment has a small amount of collected rain water which was clear with no signs of leakage The individual enclosure gates were locked. Production reports were current and up-to-date, but the well was not producing at the time of my inspection. The shared-use access road was in good condition. I walked and inspected the areas surrounding the wellhead and battery and found the natural greenscape to be free from signs of impact or degradation.
0614230607 2009-11-05 Preliminary Restoration No Violations meets restoration
0814734044 2015-06-26 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to an earlier inspection. On my previous inspection, I had noted that the drain in the secondary containment was open. I had notified the owner/operator and the issue was resolved. The wellhead and battery enclosures are locked and secure. Load-lines are locked. Process safety equipment is present and in good condition. The fittings and connections are secure and free from signs of leakage. The owner is working on addendum signage to meet urban requirements.
0892994157 2015-01-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead mechanical plunger lift system enclosure is open on one side. Valves and connections are secure and free from signs of leakage or problems. At the time of my inspection, the area is covered with several inches of snow. Access to the wellhead and battery are via the shared residential driveway which has been plowed and is passable. Valves and connections at the battery are secure. Load-outs are bull-plugged and locked. I did not observe any problems at the time of this inspection.
1150917046 2012-04-23 UrbanProduction Wells No Violations My inspection today found no violations. Well is in compliance.
1172897284 2013-04-01 Preliminary Restoration No Violations The producing unit consists of the following elements: a production wellhead and a storage tank battery. The production wellhead is fitted with a mechanical plunger lift system and is currently producing. The pumpjack unit is enclosed in an 8-foot board-on-board enclosure which is locked. The tank battery consists of 1 100-barrel steel tank, 1 50-barrel poly tank, separator, and 2 domestic meters. The battery is enclosed in a chain-link enclosure. Safety equipment (carbon filter, spark arrestor, low-pressure relief valve) is present. The secondary containment is present and in good condition. No violations noted.
1223149374 2017-04-27 UrbanProduction Wells No Violations I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I noted the following: a wellhead with plunger-lift system and associated tank battery in separate board-on-board enclosures located on a residential parcel. The enclosure gates were locked and secure. Fittings and connections at the wellhead were secure. . Fittings and connections at the battery were secure. The load-line valves were plugged and locked. The tank lids were closed and sealed. The secondary containment drain was secure. There was some standing water in the containment area from recent rainfall. The water was clear with no signs of floating oil or sheen. The gravel-paved access road is shared with the residence , and was level and dry. I noted that the carbon filter canister, which had been recently changed out, was showing some signs of corrosion and will need to be replaced. I walked the areas surrounding the well and battery systems and observed the natural soils and vegetation to be free from signs of leaks, spills, or other adverse impact from the on-going production activity. I notified Don Nething with Ohio Valley about the need for maintenance at the carbon filter.
1341910268 2013-10-28 UrbanProduction Wells No Violations The unit is producing and no problems noted.
1433430111 2015-06-04 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and battery are located behind a single-family residence on Royalwood Road. Access to the elements are via the shared driveway. The well is comprised of a mechanical plunger lift system is a board-on-board enclosure. Fittings and connections are secure and free from signs of leakage. The surface casing is plumbed to a motor valve. The enclosure is locked and ID is present but is lacking complete required information. The battery is comprised of one 100-barrel steel production tank and 1 50-barrel brine tank in a separate board-on-board enclosure. Process safety equipment is present. Secondary containment is intact and dry. The areas surrounding the well and battery are comprised of meadow grass. Some portions are being used for equipment storage by the land owner. I did not observe any signs of impact from the on-going production activity. I advised the well owner that signage requires updating. The owner indicated that new signage is in process.
1470558610 2009-11-05 Preliminary Restoration No Violations
1583945589 2020-3-11 0:00: UP No Violations 1.00
1601782082 2012-11-06 UrbanPreliminary Restoration No Violations I visited well site with supervisor Tom Hill. Well site has paved entry for first 100 to gate. Wellhead is a pump jack and is surrounded by board on board fence. There is a dike around wellhead and the area is clean and neat with no obstructions in the area. The tank battery is surrounded by board on board fence with two 110 barrel storage tanks and the dike will hold sufficient liquid for one tank. There is one 50 barrel brine tank, a separator, and a metering run. There are two load lines secured with locks. The site lacks identification signs at this time. I placed a call to the well owners and signs will be erected within two weeks. Urban preliminary restoration not approved pending installation of signs.
1918593260 2011-09-07 UrbanProduction Wells No Violations Urban Producing Well status check. No violations found. Well is in compliance with 1501-9-9-05.
643547927 2019-5-1 0:00:0 UP No Violations
814734044 2015-6-26 0:00: UP No Violations

For data sources see[9]

References