X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21904

Well Details

Well ID: 34-035-21904
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PEP DRILLING LLC
Well Pad ID:
Farm/Lease Name: BEECHMONT COUNTRY CLUB
License Status: Producing
License Date: 2006-10-12
Spud Date: 2006-10-11
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 2006-10-22
Well Total Depth: 4120.00 ft
Configuration: Directional
Latitude: 41.460000
Longitude: -81.470000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-05-18 Proposed Formations:CLINTON, Issued Date:5/18/2006, Expired Date:5/18/2007 6:00:00 AM, Drilling unit acres:178.176, Proposed Well Type:OG, Proposed Well Class:EW
APP 2006-10-12 Proposed Formations:CLINTON, Issued Date:10/12/2006, Expired Date:10/12/2007 6:00:00 AM, Drilling unit acres:178.176, Proposed Well Type:OG, Proposed Well Class:EW
Completed 2006-10-22 RBDMS Rec
Reached Total Depth 2006-10-22 RBDMS Rec
Completion Report Received 2007-01-09 RBDMS Rec
Construction Permit Expires 2007-10-12 RBDMS Rec
Change of Owner 2016-03-04 Operator changed from 1198, PIPES PURSIE E to 9640, PEP DRILLING LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-03-07 3910 3958 126
3910 3958 126
3910 3958 126

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2450 Bbl 15600 1000 GALLONS ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 PIPES PURSIE E 15987.00 479.00 355
2008 PIPES PURSIE E 9838.00 233.00 365
2009 PIPES PURSIE E 7023.00 167.00 365
2010 PIPES PURSIE E 5051.00 104.00 365
2011 PIPES PURSIE E 0.00 88.00 365
2012 PIPES PURSIE E 3903.00 62.00 366
2013 PIPES PURSIE E 3717.00 77.00 365
2014 PIPES PURSIE E 4016.00 40.00 365
2016 PEP DRILLING LLC 4096.00 33.00 365
2017 PEP DRILLING LLC 1520.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 PIPES PURSIE E Brine 1531 355
2008 PIPES PURSIE E Brine 484 365
2009 PIPES PURSIE E Brine 1186 365
2010 PIPES PURSIE E Brine 403 365
2011 PIPES PURSIE E Brine 292 365
2012 PIPES PURSIE E Brine 86 366
2013 PIPES PURSIE E Brine 83 365
2014 PIPES PURSIE E Brine 16 365
2016 PEP DRILLING LLC Brine 0 365
2017 PEP DRILLING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1072448565 2014-10-15 0:00 UP No Violations
-1361247562 2010-2-2 0:00:0 PL No Violations
-1402112311 2006-11-14 0:00 CT No Violations
0144127567 2006-10-24 Drill / Deepen / Reopen No Violations working on location
0652214500 2006-10-11 Drill / Deepen / Reopen No Violations cementing conductor
1072448565 2014-10-15 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. This well was completed on 10/22/2006. The wellhead and battery are located within the Beachmont Country Club facility on Chagrin Blvd. Access to the wellhead and battery are from the multi-use driveway shared with the facility. There is no dedicated access road. The wellhead is fitted with a mechanical plunger lift system and is located in a locked and gated chain-link enclosure. The fittings and connections are intact and appear functioning normally. The tank battery is comprised of 2 100-barrel low-boy production tanks, 1 100-barrel brine tank, and separator unit in a chain-link enclosure. The interior areas are in good condition and free from signs of leakage or problems. Spacing of elements meets requirements. Process safety gear (spark arrestor, low-pressure relief valve, carbon filter) are present. The secondary containment is intact and free from fluids. Enclosure gates are locked. I did not observe any problems at the time of this inspection.
1160661330 2006-10-11 Drill / Deepen / Reopen Violations Noted on site to cover cement job for conductor .Found company not drilling on perposed location

Checked distance to frist well apporox 160 then checked distacne to ground keeper house to south east approx 155.Advised company to submit reveised and froms to columbus for a reviesed location permit.

1161786237 2006-10-24 Drill / Deepen / Reopen No Violations on site rigging down to move
1164637085 2006-10-17 Drill / Deepen / Reopen No Violations
1164640557 2006-10-31 Drill / Deepen / Reopen No Violations status check
1361247562 2010-02-02 Preliminary Restoration No Violations No violation.
1362878898 2006-10-14 Drill / Deepen / Reopen No Violations surface
1402112311 2006-11-14 Completion Testing No Violations pits closed
144127567 2006-10-24 0:00 DD No Violations
1767728638 2017-05-30 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity and as a follow-up to a previous uncontrolled release of oil into the secondary containment (shared with the #2-1898). At the time of this inspection, I observed the following: the well had been returned to production. The fittings and connections at the wellhead were secure and free from leakage. The enclosure gates were locked and secure. I walked the areas surrounding the wellhead and battery and found no signs of leaks or impact from the on-going production activity.
2114020934 2015-12-11 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and associated tank battery (shared with the #2-1904 well) are located in a maintenance and materials storage area at the country club facility. At the time of this inspection, the enclosure gates at the wellhead and battery are locked and secure. Load lines are locked. Fittings and connections at the wellhead are secure and free from signs of leakage or problems. Areas around the wellhead and battery are comprised of grassy vegetation and various piles of sand and other material being utilized by the country club. I observed the following maintenance deficiency: The lids on two of the production tanks are missing the wing nut and are not capable of sealing. Ive notified Mark Smith with PEP Drilling Co. about the deficiency.
652214500 2006-10-11 0:00 DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1160661330 US-OH-104270 2006-10-12 Failure to comply with permit conditions

For data sources see[9]

References