34-035-21892

Well Details

Well ID: 34-035-21892
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: RANKIN C R UNIT
License Status: Producing
License Date: 2006-06-05
Spud Date: 2006-09-04
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-09-15
Well Total Depth: 3626.00 ft
Configuration: Directional
Latitude: 41.500000
Longitude: -81.410000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-03-03 Proposed Formations:CLINTON, Issued Date:3/3/2006, Expired Date:3/3/2007 6:00:00 AM, Drilling unit acres:20.54, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2006-03-17 ADDED TARGET INFORMATION TO PERMIT. TARGET INFORMATION: 195'SL & 590'WL OF LOT 7, TRACT 3; X= 2,296,490; Y= 670,205; ELEV.= 1040'.
APP 2006-06-05 Proposed Formations:CLINTON, Issued Date:6/5/2006, Expired Date:6/5/2007 6:00:00 AM, Drilling unit acres:20.54, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-09-15 RBDMS Rec
Reached Total Depth 2006-09-15 RBDMS Rec
Correction to Well 2007-01-19 CHANGE IN TARGET INFORMATION: FOOTAGE= 225'SL & 610'WL OF LOT 7, TRACT 3; X= 2,296,505; Y= 670,236 (SOURCE OF LOCATION: AS DRILLED SURVEY)
Construction Permit Expires 2007-06-05 RBDMS Rec
Completion Report Received 2007-07-06 RBDMS Rec
Correction to Well 2007-12-21 CHANGE IN TARGET INFORMATION: NEW X= 2,296,510; NEW Y= 670,235 AND NEW TARGET ELEVATION=1042'.
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-10-26 3450 3476 31
3450 3476 31
3450 3476 31

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 59222 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 BASS ENERGY CO INC 8764.00 42.00 365
2008 BASS ENERGY CO INC 32511.00 67.00 365
2009 BASS ENERGY CO INC 23195.00 35.00 365
2010 BASS ENERGY CO INC 32572.00 0.00 365
2011 BASS ENERGY CO INC 12431.00 0.00 0
2012 BASS ENERGY CO INC 16944.00 0.00 366
2013 BASS ENERGY CO INC 12468.00 0.00 365
2014 BASS ENERGY CO INC 10279.00 0.00 365
2015 BASS ENERGY CO INC 11826.00 0.00 365
2016 BASS ENERGY CO INC 7302.00 0.00 365
2017 BASS ENERGY CO INC 12333.00 0.00 365
2018 BASS ENERGY CO INC 12745.00 60.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 BASS ENERGY CO INC Brine 40 365
2008 BASS ENERGY CO INC Brine 9 365
2009 BASS ENERGY CO INC Brine 89 365
2010 BASS ENERGY CO INC Brine 66 365
2011 BASS ENERGY CO INC Brine 0
2012 BASS ENERGY CO INC Brine 62 366
2013 BASS ENERGY CO INC Brine 0 365
2014 BASS ENERGY CO INC Brine 40 365
2015 BASS ENERGY CO INC Brine 20 365
2016 BASS ENERGY CO INC Brine 0 365
2017 BASS ENERGY CO INC Brine 28 365
2018 BASS ENERGY CO INC Brine 22 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0377943516 2006-09-05 Drill / Deepen / Reopen No Violations conductor cementing good returns
0807137206 2007-12-12 Preliminary Restoration No Violations
1131982355 2010-11-23 Production Wells No Violations
1187679749 2017-10-11 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift and associated tank battery located in the back of a residential property. At the time of this inspection, I observed the following: The enclosure gates were locked. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery, and found no signs of impact or degradation attributable to the production system. The dedicated access drive and entry were in good condition.
1319175576 2006-11-16 Drill / Deepen / Reopen No Violations area graded
1408471771 2014-08-19 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 09/15/2006. The unit is producing and production reports are current. The well is located in a upscale suburban area with large lots, and densely wooded areas around the well and battery. The producing unit is accessed via a dedicated, gravel-paved access road which extends north from Cedar Road. The access road is level, and well drained with no signs of erosional deficits. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate board-on-board enclosures. The valve fittings, connections, and other production appurtenances appear to be well maintained and are free from signs of leakage or other problems. The battery is comprised of 1 steel 100-barrel production tank, 1 50-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead and are in good condition. I observed no issues or problems requiring attention at the time of my inspection.
1637670829 2006-09-05 Drill / Deepen / Reopen No Violations Rig moveing on
377943516 2006-9-5 0:00:0 DD No Violations
807137206 2007-12-12 0:00 PL No Violations

For data sources see[9]