Well Details

Well ID: 34-035-21833
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: INDEPENDENCE RESEARCH UNIT
License Status: Producing
License Date: 2005-01-26
Spud Date: 2005-03-04
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-03-15
Well Total Depth: 3422.00 ft
Configuration: Directional
Latitude: 41.370000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-01-26 Proposed Formations:NEWBURG & CLINTON, Issued Date:1/26/2005, Expired Date:1/26/2006 6:00:00 AM, Drilling unit acres:56, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-03-04 RBDMS Rec
Completed 2005-03-15 RBDMS Rec
Reached Total Depth 2005-03-15 RBDMS Rec
Completion Report Received 2005-07-20 RBDMS Rec
Correction to Well 2005-08-05 CORRECTION TO TARGET INFORMATION: LOCATION= 315'SL & 170'EL OF LOT 41, TRACT 2; X= 2,235,753; Y= 624,359
Construction Permit Expires 2006-01-26 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-09-16 3182 3206 49
3182 3206 49
3182 3206 49

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 55100 Gal 30000 500 GALLONS HCL ACID…WELL KICKED OFF FLOWING 9 BBL/HR

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 BASS ENERGY CO INC 6971.00 3922.00 365
2006 BASS ENERGY CO INC 7601.00 4374.00 365
2007 BASS ENERGY CO INC 6350.00 3243.00 365
2008 BASS ENERGY CO INC 6195.00 2763.00 365
2009 BASS ENERGY CO INC 6305.00 2301.00 365
2010 BASS ENERGY CO INC 6159.00 1571.00 365
2011 BASS ENERGY CO INC 4273.00 1456.00 0
2012 BASS ENERGY CO INC 4190.00 1417.00 366
2013 BASS ENERGY CO INC 2778.00 1301.00 365
2014 BASS ENERGY CO INC 2708.00 1188.00 365
2015 BASS ENERGY CO INC 2551.00 969.00 365
2016 BASS ENERGY CO INC 1811.00 966.00 365
2017 BASS ENERGY CO INC 1961.00 888.00 365
2018 BASS ENERGY CO INC 1576.00 709.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 BASS ENERGY CO INC Brine 457 365
2006 BASS ENERGY CO INC Brine 20 365
2007 BASS ENERGY CO INC Brine 0 365
2008 BASS ENERGY CO INC Brine 65 365
2009 BASS ENERGY CO INC Brine 35 365
2010 BASS ENERGY CO INC Brine 0 365
2011 BASS ENERGY CO INC Brine 0
2012 BASS ENERGY CO INC Brine 38 366
2013 BASS ENERGY CO INC Brine 18 365
2014 BASS ENERGY CO INC Brine 0 365
2015 BASS ENERGY CO INC Brine 28 365
2016 BASS ENERGY CO INC Brine 15 365
2017 BASS ENERGY CO INC Brine 0 365
2018 BASS ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-117198200 2015-3-2 0:00:0 WR No Violations 0.50
-1262664021 2005-10-7 0:00: PL No Violations
-1769616187 2006-4-14 0:00: PW No Violations
-1895497875 2007-2-8 0:00:0 PW No Violations
-1980396354 2005-3-7 0:00:0 DD No Violations
-411711565 2013-9-23 0:00: UP No Violations
-808405738 2017-8-28 0:00: UP No Violations 0.50
0117198200 2015-03-02 Work Over Reconditioning No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located with in the confines of the Cleveland Clinic Home Care office facility on Brecksville Road. The wellhead is comprised of a mechanical plunger lift in a chain-link enclosure. The battery is comprised of 2 100-barrel production tanks, 2 50-barrel brine tanks, separators inside a separate chain-link enclosure. The battery is shared with the #2-1816 well. Fittings and connections at the wellhead are secure and free from signs of leakage. Gates and load-outs are secure and locked. Signage is present and complete. I did not observe any evidence of impact relating to on-going production activity.
0411711565 2013-09-23 UrbanProduction Wells No Violations The wellhead mechanical plunger lift and aboveground (AST) battery are enclosed in separate chain-link fences. The well is producing. The battery is comprised of 4 100-barrel steel production tanks and 1 50-barrel steel brine tank. Spacing and safety equipment are in accordance with rules. Gates are locked and ID placard is present. Secondary containment is adequate. The battery is shared with the #1816 unit. No problems or violations.
0808405738 2017-08-28 UrbanProduction Wells No Violations I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery, shared with the Independence Research Park #1, located on the Cleveland Clinic facility. Fittings and connections at the wellhead and battery were secure, with the following exception: I noted evidence of leakage (salt accumulation) of brine from a fitting at the wellhead. Also, I noted that the signage identification at the wellhead and battery were incorrect. I notified the well owner about the maintenance issues. Otherwise, the enclosure gates were secure. The load-lines were secure. The secondary containment was intact and dry. I found no other signs of problems at this inspection.
1131040641 2005-10-04 Production Wells No Violations
1262664021 2005-10-07 Preliminary Restoration No Violations
1545771813 2006-12-05 Production Wells No Violations
1769616187 2006-04-14 Production Wells No Violations Tank Battery
1821097367 2019-10-28 0:00 UP No Violations 0.50
1895497875 2007-02-08 Production Wells No Violations
1980396354 2005-03-07 Drill / Deepen / Reopen No Violations
2091060798 2010-01-27 Production Wells No Violations No violations!

For data sources see[9]