34-035-21796

Well Details

Well ID: 34-035-21796
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: BRECKSVILLE RD
License Status: Producing
License Date: 2005-01-26
Spud Date: 2005-02-19
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-02-23
Well Total Depth: 3212.00 ft
Configuration: Vertical
Latitude: 41.390000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-01-20 Proposed Formations:CLINTON, Issued Date:1/20/2004, Expired Date:1/19/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2005-01-26 Proposed Formations:ORISKANY/NEWBURG/CLINTON, Issued Date:1/26/2005, Expired Date:1/26/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-02-19 RBDMS Rec
Completed 2005-02-23 RBDMS Rec
Reached Total Depth 2005-02-23 RBDMS Rec
Completion Report Received 2005-08-01 RBDMS Rec
Construction Permit Expires 2006-01-26 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-09-26 2979 3033 34
2979 3033 34
2979 3033 34

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 75300 Gal 0 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 DUCK CREEK ENERGY INC 10745.00 557.00 119
2006 DUCK CREEK ENERGY INC 21886.00 643.00 365
2007 DUCK CREEK ENERGY INC 7543.00 205.00 365
2008 DUCK CREEK ENERGY INC 4502.00 152.00 365
2009 DUCK CREEK ENERGY INC 2263.00 65.00 365
2010 DUCK CREEK ENERGY INC 1678.00 0.00 365
2011 DUCK CREEK ENERGY INC 7732.00 368.00 365
2012 DUCK CREEK ENERGY INC 3464.00 236.00 366
2013 DUCK CREEK ENERGY INC 2613.00 78.00 365
2014 DUCK CREEK ENERGY INC 2284.00 93.00 365
2015 DUCK CREEK ENERGY INC 1584.00 75.00 365
2016 DUCK CREEK ENERGY INC 1560.00 58.00 365
2017 DUCK CREEK ENERGY INC 1531.00 80.00 365
2018 DUCK CREEK ENERGY INC 1163.00 26.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 DUCK CREEK ENERGY INC Brine 410 119
2006 DUCK CREEK ENERGY INC Brine 145 365
2007 DUCK CREEK ENERGY INC Brine 203 365
2008 DUCK CREEK ENERGY INC Brine 88 365
2009 DUCK CREEK ENERGY INC Brine 48 365
2010 DUCK CREEK ENERGY INC Brine 50 365
2011 DUCK CREEK ENERGY INC Brine 468 365
2012 DUCK CREEK ENERGY INC Brine 224 366
2013 DUCK CREEK ENERGY INC Brine 142 365
2014 DUCK CREEK ENERGY INC Brine 173 365
2015 DUCK CREEK ENERGY INC Brine 84 365
2016 DUCK CREEK ENERGY INC Brine 128 365
2017 DUCK CREEK ENERGY INC Brine 76 365
2018 DUCK CREEK ENERGY INC Brine 8 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-103844642 2005-2-15 0:00: DD No Violations
-1370579947 2005-2-23 0:00: DD No Violations
-1563873224 2007-8-8 0:00:0 PL No Violations
-1789498735 2017-2-10 0:00: UP No Violations 0.50
-984282641 2017-10-6 0:00: UP No Violations 0.50
0103844642 2005-02-15 Drill / Deepen / Reopen No Violations location wet trouble get equipment on.
0984282641 2017-10-06 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift system and associated tank battery located adjacent to a cemetery parcel. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I did note that 210-barrel stock tank was showing some areas of severe corrosion and in need of repair/replacement soon. I walked the areas surrounding the wellhead and battery, and found no signs of impact or degradation attributable to the production system. I notified Duck Creek Energy about the pending need for repair/replacement of the 210-barrel stock tank.
1370579947 2005-02-23 Drill / Deepen / Reopen No Violations Drilling 2470
1425326430 2015-03-02 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and tank battery are located in a small undeveloped area on the east side of Brecksville Road, adjacent to the Maple Shade Cemetery. The wellhead is comprised of a plunger lift system is a small, triangular chain-link enclosure. The battery is comprised of 1 210-barrel production tank, 1 100-barrel brine tank, separator, and Dominion metering run inside a separate chain-link enclosure. Fittings and connections at the wellhead are secure and free from signs of leakage. The production tank is showing areas of moderate to severe corrosion but is intact at the time of this inspection. I did not observe any evidence of impact relating to on-going production activity.
1429363586 2019-10-28 0:00 UP No Violations 0.50
1534793481 2018-08-20 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I noted the following: The wellhead is comprised of a plunger lift system is a small, triangular chain-link enclosure. The battery is comprised of 2 100-barrel stock tanks, separator, and Dominion metering run inside a separate chain-link enclosure. The former 210-barrel stock tank that was corroded had been replaced. Fittings and connections at the wellhead were secure and free from signs of leakage. I did not observe any evidence of impact relating to on-going production activity.
1563873224 2007-08-08 Preliminary Restoration No Violations
1759908236 2019-6-18 0:00: PW No Violations
1789498735 2017-02-10 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate chain-link enclosures located on a parcel otherwise undeveloped. Fittings at the wellhead including flow-line connections and fittings were secure and free from leakage. The tank battery was comprised of one 210-barrel steel production tank, and one 100-barrel steel brine tank with mechanical separator. The battery is shared with the #2 wells(#2-1797). The secondary containment was present and intact. The visible system connections were secure and free from leakage. Load lines were plugged and secure. The well is surrounded by tall, grassy landscaping. The battery is bordered by level, landscaped areas and some wild vegetation. I walked the areas surrounding both the wellhead and battery and I did not observe any signs of erosional deficits or impacts associated with the producing unit. The access road was mostly well drained and stable with no signs of wash-out or other drainage problems.
2081578116 2009-10-21 Production Wells No Violations No violations

For data sources see[9]