X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21795

Well Details

Well ID: 34-035-21795
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DUCK CREEK ENERGY INC
Well Pad ID:
Farm/Lease Name: ROSBY
License Status: Plugged and Abandoned
License Date: 2019-03-15
Spud Date: 2004-04-08
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-04-14
Well Total Depth: 3055.00 ft
Configuration: Vertical
Latitude: 41.420000
Longitude: -81.660000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-01-15 Proposed Formations:CLINTON, Issued Date:1/15/2004, Expired Date:1/14/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-04-08 RBDMS Rec
Completed 2004-04-14 RBDMS Rec
Reached Total Depth 2004-04-14 RBDMS Rec
Completion Report Received 2004-06-21 RBDMS Rec
APP 2019-03-15 Proposed Formations:CLINTON, Issued Date:3/15/2019, Expired Date:3/14/2021 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2019-03-22 RBDMS Rec
Construction Permit Expires 2021-03-14 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-08-19 2876 2905 26
2876 2905 26
2876 2905 26

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 59500 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 DUCK CREEK ENERGY INC 191.00 0.00 42
2005 DUCK CREEK ENERGY INC 3209.00 234.00 365
2006 DUCK CREEK ENERGY INC 1734.00 154.00 365
2007 DUCK CREEK ENERGY INC 1210.00 80.00 365
2008 DUCK CREEK ENERGY INC 756.00 58.00 365
2009 DUCK CREEK ENERGY INC 711.00 61.00 365
2010 DUCK CREEK ENERGY INC 573.00 0.00 365
2011 DUCK CREEK ENERGY INC 462.00 61.00 365
2012 DUCK CREEK ENERGY INC 391.00 0.00 366
2013 DUCK CREEK ENERGY INC 517.00 51.00 365
2014 DUCK CREEK ENERGY INC 220.00 0.00 365
2015 DUCK CREEK ENERGY INC 50.00 0.00 365
2016 DUCK CREEK ENERGY INC 0.00 0.00 365
2017 DUCK CREEK ENERGY INC 0.00 0.00 365
2018 DUCK CREEK ENERGY INC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 DUCK CREEK ENERGY INC Brine 393 42
2005 DUCK CREEK ENERGY INC Brine 561 365
2006 DUCK CREEK ENERGY INC Brine 298 365
2007 DUCK CREEK ENERGY INC Brine 160 365
2008 DUCK CREEK ENERGY INC Brine 152 365
2009 DUCK CREEK ENERGY INC Brine 100 365
2010 DUCK CREEK ENERGY INC Brine 105 365
2011 DUCK CREEK ENERGY INC Brine 68 365
2012 DUCK CREEK ENERGY INC Brine 50 366
2013 DUCK CREEK ENERGY INC Brine 70 365
2014 DUCK CREEK ENERGY INC Brine 50 365
2015 DUCK CREEK ENERGY INC Brine 0 365
2016 DUCK CREEK ENERGY INC Brine 0 365
2017 DUCK CREEK ENERGY INC Brine 0 365
2018 DUCK CREEK ENERGY INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-10201690 2013-5-30 0:00: UP No Violations
-1074921126 2019-11-4 0:00: PB No Violations
-1614278002 2016-3-15 0:00: UP No Violations 1.00
-1797056818 2017-12-19 0:00 UP No Violations 0.50
0010201690 2013-05-30 UrbanProduction Wells No Violations The producing unit consists of the following elements: a wellhead with pumpjack and a tank battery system. The tank battery is comprised of one 210 and one 100-barrel steel tank, and mechanical separator. Secondary containment is present and adequate. The tank battery is shared with the Rosby 2 (#2-1794). The 210-barrel tank is beginning to fail at a weld on the side. I did not observe any other problems or violations. I contacted Duck Creek about the need for tank maintenance.
0044240901 2011-10-10 UrbanPreliminary Restoration No Violations Urban Preliminary Restoration inspection due. Preliminary Restoration Passed.
1614278002 2016-03-15 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and associated tank battery are located within a large-scale commercial municipal solid waste landfill and materials recycling facility and accessed via the shared-use, gravel-paved roadway. At the time of this inspection, I observed the following: a wellhead with pump jack system and tank battery with one 210-barrel steel production tank, one 100-barrel steel brine tank, and separator (the battery was being shared with the Rosby #2 well). The production elements were located at the fringe of a field office and parking area. Fittings at the wellhead were secure and free from leakage or problems. The well had become overgrown with tall, vegetation. Secondary containment was intact. Fittings and connections at the battery were secure with the following exception: a small portion of the welded seam on the 210-tank is beginning to fail and leak oil. A previous leak along the same seam which I had noted and notified the owner about had been repaired. I notified the owner the following maintenance issues need addressed: remove the overgrowth of vegetation from the wellhead area, repair the leaking tank weld. The areas beyond the wellhead and battery are comprised of a heavily-worked landscape of imported fill material, waste disposal activity, and materials storage. I did not observe any evidence of problems or impacts to the surrounding area from the on-going production.
1615722656 2004-04-19 Drill / Deepen / Reopen No Violations Rig on #2 well on lease pit still open no violation.
1701959977 2004-04-08 Drill / Deepen / Reopen No Violations on site rig setting up to drill.
1797056818 2017-12-19 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located in an active waste management operation. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. The well was not in active production. I walked the areas surrounding the well and found no signs of problems or impacts relating to the production operation.
2088286531 2019-10-28 0:00 PB No Violations 2.50
44240901 2011-10-10 0:00 UL No Violations 0.50

For data sources see[9]

References