34-035-21775

Well Details

Well ID: 34-035-21775
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DUCK CREEK ENERGY INC
Well Pad ID:
Farm/Lease Name: 550 HARVARD UNIT
License Status: Producing
License Date: 2003-04-04
Spud Date: 2003-04-29
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2003-05-04
Well Total Depth: 2878.00 ft
Configuration: Vertical
Latitude: 41.440000
Longitude: -81.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-04-04 Proposed Formations:CLINTON, Issued Date:4/4/2003, Expired Date:4/3/2004 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2003-04-29 RBDMS Rec
Completed 2003-05-04 RBDMS Rec
Reached Total Depth 2003-05-04 RBDMS Rec
Correction to Well 2003-07-03 TOWNSHIP CORRECTED TO "INDEPENDENCE".
Completion Report Received 2003-07-17 RBDMS Rec
Construction Permit Expires 2004-04-03 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-08-29 2743 2797 36
2743 2797 36
2743 2797 36

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 59000 Gal 0 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 DUCK CREEK ENERGY INC 0.00 0.00 0
2004 DUCK CREEK ENERGY INC 10488.00 119.00 310
2005 DUCK CREEK ENERGY INC 8382.00 66.00 365
2006 DUCK CREEK ENERGY INC 2969.00 0.00 365
2007 DUCK CREEK ENERGY INC 500.00 0.00 365
2008 DUCK CREEK ENERGY INC 2557.00 106.00 365
2009 DUCK CREEK ENERGY INC 1881.00 0.00 365
2010 DUCK CREEK ENERGY INC 1421.00 0.00 365
2011 DUCK CREEK ENERGY INC 1320.00 0.00 365
2012 DUCK CREEK ENERGY INC 1831.00 0.00 366
2013 DUCK CREEK ENERGY INC 1559.00 0.00 365
2014 DUCK CREEK ENERGY INC 1514.00 83.00 365
2015 DUCK CREEK ENERGY INC 362.00 0.00 365
2016 DUCK CREEK ENERGY INC 0.00 0.00 365
2017 DUCK CREEK ENERGY INC 0.00 0.00 365
2018 DUCK CREEK ENERGY INC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 DUCK CREEK ENERGY INC Brine 1830 0
2004 DUCK CREEK ENERGY INC Brine 1695 310
2005 DUCK CREEK ENERGY INC Brine 948 365
2006 DUCK CREEK ENERGY INC Brine 297 365
2007 DUCK CREEK ENERGY INC Brine 1789 365
2008 DUCK CREEK ENERGY INC Brine 1390 365
2009 DUCK CREEK ENERGY INC Brine 1357 365
2010 DUCK CREEK ENERGY INC Brine 995 365
2011 DUCK CREEK ENERGY INC Brine 1426 365
2012 DUCK CREEK ENERGY INC Brine 1167 366
2013 DUCK CREEK ENERGY INC Brine 1119 365
2014 DUCK CREEK ENERGY INC Brine 946 365
2015 DUCK CREEK ENERGY INC Brine 173 365
2016 DUCK CREEK ENERGY INC Brine 0 365
2017 DUCK CREEK ENERGY INC Brine 0 365
2018 DUCK CREEK ENERGY INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1371843126 2013-06-21 UrbanProduction Wells No Violations The producing unit consists of a production wellhead and an above-ground storage tank (AST) battery. The battery is comprised of 1 210-barrel and 1 100-barrel steel AST, and mechanical separator. ID is present. Secondary containment is present at the battery. The wellhead is fitted with a pump jack system and is producing. I did not observe any leaks or problems.
1592657966 2017-09-14 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate enclosures, both located on a parcel occupied by a church. The enclosure gates were locked and secure. The load-line valves were secure. Tank lids were closed and secure. The secondary containment was intact and dry. I walked the areas surrounding the well and battery and found no signs of impacts or problems. I had noted during a previous inspection that the 2-inch cross-over line at the battery was corroded. The condition remained at this inspection, although there was no sign of leakage or loss of integrity. I notified Dave Mansbury with Duck Creek about the potential problem.
2135577048 2016-11-16 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with pump jack system and associated tank battery, both located within the confines of a materials supply and storage operation. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. Tank lids were closed and secure. Secondary containment was intact and free from signs of spills or leakage. Load lines were plugged and secure. I noted the following: the 2-inch cross-over line between the production tank and brine tank was corroded and should be replaced before it fails. I contacted Dave Mansbury with Duck Creek Energy and advised about the need for maintenance at the cross-over lines.

For data sources see[9]

References