X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21193

Well Details

Well ID: 34-035-21193
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: HUGE ROBERT C
Well Pad ID:
Farm/Lease Name: HUGH HENDRICKS & CEI CO
License Status: Producing
License Date: 1983-09-28
Spud Date: 1983-10-24
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1983-10-29
Well Total Depth: 2872.00 ft
Configuration: Vertical
Latitude: 41.370000
Longitude: -81.870000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-05-03 1451 R C H CO GeoDate 5/3/83
Oil and Gas 1983-05-03 Issued Date 5/3/83 Expired Date 10/30/83 Acres 0020831 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1983-09-28 2559 WNT OPERATING INC GeoDate 9/28/83
Oil and Gas 1983-09-28 Issued Date 5/3/83 Expired Date 10/30/83 Acres 0020831 Tool Type RTA Proposed Formation CLINTON Proposed Depth 02872 Proposed Drill Depth 02872
Original Spud 1983-10-24 R.L. 10-1-83
Completed 1983-10-29 R.L. 10-1-83
Reached Total Depth 1983-10-29 R.L. 10-1-83
Construction Permit Expires 1983-10-30 R.L. 10-1-83
Completion Report Received 1983-11-25 R.L. 10-1-83
Change of Owner 2001-09-05 Operator changed from 2559, WNT OPERATING INC to 2543, TIPKA ENERGY DEVLOP CO
Change of Owner 2002-02-12 Operator changed from 2543, TIPKA ENERGY DEVLOP CO to 7171, HUGE ROBERT C
Last Compliance Report 2016-11-10 R.L. 10-1-83
Record Last Modified 2017-02-15 R.L. 10-1-83

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 2740 2800 0
2740 2800 0
2006-09-11 2741 2786 15
2741 2786 15
2740 2800 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 71000 Gal 50000 FRAC;71MG H2O,50M# SD

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 WNT OPERATING INC 6104.00 191.00 365
1987 WNT OPERATING INC 4094.00 108.00 365
2000 WNT OPERATING INC 644.00 74.00 365
2001 WNT OPERATING INC 464.00 0.00 365
2002 HUGE ROBERT C 606.00 0.00 365
2005 HUGE ROBERT C 512.00 0.00 365
2006 HUGE ROBERT C 433.00 0.00 365
2007 HUGE ROBERT C 457.00 0.00 365
2008 HUGE ROBERT C 484.00 0.00 365
2009 HUGE ROBERT C 464.00 0.00 365
2010 HUGE ROBERT C 452.00 0.00 365
2011 HUGE ROBERT C 706.00 0.00 365
2013 HUGE ROBERT C 249.00 0.00 365
2014 HUGE ROBERT C 427.00 0.00 365
2015 HUGE ROBERT C 368.00 0.00 365
2016 HUGE ROBERT C 527.00 0.00 365
2017 HUGE ROBERT C 342.00 0.00 365
2018 HUGE ROBERT C 181.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 WNT OPERATING INC Brine 0 365
1987 WNT OPERATING INC Brine 0 365
2000 WNT OPERATING INC Brine 0 365
2001 WNT OPERATING INC Brine 0 365
2002 HUGE ROBERT C Brine 0 365
2005 HUGE ROBERT C Brine 0 365
2006 HUGE ROBERT C Brine 0 365
2007 HUGE ROBERT C Brine 0 365
2008 HUGE ROBERT C Brine 0 365
2009 HUGE ROBERT C Brine 0 365
2010 HUGE ROBERT C Brine 0 365
2011 HUGE ROBERT C Brine 0 365
2013 HUGE ROBERT C Brine 0 365
2014 HUGE ROBERT C Brine 0 365
2015 HUGE ROBERT C Brine 0 365
2016 HUGE ROBERT C Brine 0 365
2017 HUGE ROBERT C Brine 0 365
2018 HUGE ROBERT C Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1248794444 2018-1-22 0:00: UP No Violations 0.50
-1249411806 2015-12-18 0:00 UP No Violations 1.00
-1585280694 2017-8-14 0:00: UP No Violations 1.00
0713079562 2018-01-19 UrbanProduction Wells No Violations I inspected the well location as a follow-up to Chiefs Order #2016-413 issued for missing liability insurance. At the time of this inspection, the well was in production. I contacted well owner Robert Huge about the missing insurance. He indicated he would have the certificate sent to ODNR Columbus. I followed up with a phone call on 1/19/18 and left a message. A response was pending.
1248794444 2018-01-22 UrbanProduction Wells No Violations I inspected this well as a follow-up to a Chiefs Order 2016-413 issued for expired bond/insurance. At the time of this inspection I found the well to be capable of production with current reports. There remained no updated bond/insurance on file. I contacted Robert Huge regarding the lapsed bond/insurance. Mr. Huge said he was not aware there was a problem. I forwarded contact information for ODNR bonding and insurance representatives so that he could resolve. I reminded Mr. Huge that the active Chiefs Order stipulates that the well may not be produced until the Chiefs Order had been rescinded.
1249411806 2015-12-18 UrbanProduction Wells Violations Noted I inspected this well location as a part of routine inspection activity. The well and battery are located in a wooded area in an otherwise commercial and light industrial portion of Berea. The producing well is comprised of two 100-barrel steel tanks, separator unit and pump jack. The battery and wellhead were observed to be in separate, chain-link enclosures. At the time of my inspection, I observed the following maintenance/safety deficiencies: The interior of both the battery and the wellhead were significantly overgrown with large diameter (> 6 inches) trees. The production elements have been rendered non-functional due to advanced vegetation overgrowth and lack of maintenance. The tank battery was observed to be inaccessible. There was no unit identification. The owner must remove all unused equipment from the site including inoperable pump jack and unused storage tanks. Any equipment that remains must be maintained consistent with reasonably prudent operations. Overgrowth of vegetation and trees must be removed. The owner must display signage in accordance with 1501:9-9-05(E)(1). The owner must correct these deficiencies by 01/22/2016. Please contact Inspector Stephen Tompkins at 330-907-4647 with any questions regarding this inspection.
1471961900 2016-08-23 Temporary Abandoned Annular Disposal No Violations I inspected this well as part of evaluation of Tempoary Abandoned/Annular Disposal status. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated storage tank battery, The well was in production and was not equipped for annular disposal.
1585280694 2017-08-14 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previous compliance notice regarding lack of signage and overgrown wellhead and battery enclosures. At the time of this inspection, I observed that the signage deficiency had been remedied, and the wellhead enclosure had been cleared, however the battery enclosure remained heavily overgrown. I contacted Robert Huge about the remaining deficiency. He reported that due to an accident, he had been delayed, and requested additional time to comply. We agreed to re-visit in the next two months.
1589899730 2020-5-19 0:00: PW No Violations 0.50
1787148148 2016-08-25 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had observed that there was no identification at the well or associated battery. I had also noted that the interior of both the wellhead and tank battery enclosures was significantly overgrown with large trees and vegetation, rendering access to the interior of the respective enclosures impossible. Subsequent discussions with Mr. Robert Huge have indicated that the owner is taking steps to remedy the deficiencies. At the time of this inspection, I noted that an ID sign had been placed at the well. I had observed that the trees and other vegetation were still present. I contacted Mr. Huge and we agreed to meet at the location within the next two weeks to review the deficiencies.
713079562 2018-1-19 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1249411806 US-OH-106677 2016-02-19 ID (a-i)
1249411806 US-OH-106678 2016-02-19 OPERATIONMAINTANCE (a-c)

For data sources see[9]

References