34-035-21138

Well Details

Well ID: 34-035-21138
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: GILMOUR ACADEMY CORP
Well Pad ID:
Farm/Lease Name: GILMOUR ACADEMY CORP
License Status: Producing
License Date: 1981-10-29
Spud Date: 1982-01-04
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1982-01-12
Well Total Depth: 6105.00 ft
Configuration: Vertical
Latitude: 41.500000
Longitude: -81.430000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-12-29 3767 GILMOUR ACADEMY CORP GeoDate 12/29/81
Original Spud 1982-01-04 GL=1113.7, DF=1121.7, KB=1123.7
Completed 1982-01-12 GL=1113.7, DF=1121.7, KB=1123.7
Reached Total Depth 1982-01-12 GL=1113.7, DF=1121.7, KB=1123.7
Plugged Back 1982-01-13 GL=1113.7, DF=1121.7, KB=1123.7
Completion Report Received 1982-04-10 GL=1113.7, DF=1121.7, KB=1123.7
Construction Permit Expires 1982-04-27 GL=1113.7, DF=1121.7, KB=1123.7
Record Last Modified 2017-02-15 GL=1113.7, DF=1121.7, KB=1123.7

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-04-10 3488 3512 20
3488 3512 20
3488 3512 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 35490 Gal 34000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 DOME DRILLING CO 7763.00 0.00 365
1993 DOME DRILLING CO 3410.00 0.00 365
1994 DOME DRILLING CO 17692.00 42.00 365
1995 DOME DRILLING CO 24319.00 0.00 365
1996 DOME DRILLING CO 30334.00 50.00 365
1997 DOME DRILLING CO 37202.00 17.00 365
1998 DOME DRILLING CO 26698.00 0.00 365
1999 DOME DRILLING CO 19185.00 25.00 365
2000 DOME DRILLING CO 20983.00 41.00 365
2001 DOME DRILLING CO 12140.00 15.00 365
2002 DOME DRILLING CO 10455.00 0.00 365
2003 DOME DRILLING CO 16390.00 0.00 365
2004 DOME DRILLING CO 35716.00 0.00 365
2005 DOME DRILLING CO 25419.00 22.00 365
2006 DOME DRILLING CO 15528.00 0.00 365
2007 DOME DRILLING CO 8855.00 0.00 365
2008 DOME DRILLING CO 26647.00 36.00 365
2009 DOME DRILLING CO 15210.00 0.00 365
2010 GREEN ENERGY INC 9822.00 0.00 365
2011 GREEN ENERGY INC 9003.00 0.00 365
2012 GREEN ENERGY INC 2328.00 0.00 366
2013 GILMOUR ACADEMY CORP 2858.00 0.00 365
2014 GILMOUR ACADEMY CORP 854.00 0.00 365
2015 GILMOUR ACADEMY CORP 508.00 33.00 365
2016 GILMOUR ACADEMY CORP 575.00 0.00 365
2017 GILMOUR ACADEMY CORP 4788.00 0.00 365
2018 GILMOUR ACADEMY CORP 4519.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 DOME DRILLING CO Brine 0 365
1993 DOME DRILLING CO Brine 0 365
1994 DOME DRILLING CO Brine 0 365
1995 DOME DRILLING CO Brine 0 365
1996 DOME DRILLING CO Brine 31 365
1997 DOME DRILLING CO Brine 45 365
1998 DOME DRILLING CO Brine 0 365
1999 DOME DRILLING CO Brine 0 365
2000 DOME DRILLING CO Brine 36 365
2001 DOME DRILLING CO Brine 57 365
2002 DOME DRILLING CO Brine 0 365
2003 DOME DRILLING CO Brine 0 365
2004 DOME DRILLING CO Brine 41 365
2005 DOME DRILLING CO Brine 0 365
2006 DOME DRILLING CO Brine 50 365
2007 DOME DRILLING CO Brine 0 365
2008 DOME DRILLING CO Brine 20 365
2009 DOME DRILLING CO Brine 0 365
2010 GREEN ENERGY INC Brine 28 365
2011 GREEN ENERGY INC Brine 23 365
2012 GREEN ENERGY INC Brine 0 366
2013 GILMOUR ACADEMY CORP Brine 15 365
2014 GILMOUR ACADEMY CORP Brine 0 365
2015 GILMOUR ACADEMY CORP Brine 8 365
2016 GILMOUR ACADEMY CORP Brine 0 365
2017 GILMOUR ACADEMY CORP Brine 42 365
2018 GILMOUR ACADEMY CORP Brine 32 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1559252469 2016-9-9 0:00:0 UP No Violations 1.00
-1789244959 2018-7-13 0:00: UP No Violations 1.00
-542491476 2016-12-19 0:00 UP No Violations 1.00
-761393691 2013-11-25 0:00 UP No Violations
0542491476 2016-12-19 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger-lift system in a small, chain-link enclosure. The well was located at the edge of an asphalt-paved parking area and on the fringe of a ball field. The enclosure was locked and secure. The interior of the well containment was dry and free of vegetation, and evidence of leakage or other problems. Fittings and connections were secure. The associated battery is located 500 feet north of the wellhead, at the fringe of another ball field. The battery was comprised of one 100-barrel steel production tank, one 50-barrel plastic brine tank. Load lines were locked and secure. Enclosure gates were locked. Tank lids were closed and secure. Secondary containment was intact. I walked the areas around the wellhead and battery. These areas consist mainly of managed turf grass and were free from signs of drainage problems, or other signs of impact relating to the on-going production.
0761393691 2013-11-25 UrbanProduction Wells Violations Noted Safety equipment and locks have been remedied and no other problems remain.
1064584725 2003-09-25 Production Wells No Violations Inspected well site and tank battery. 210BBL seperator plasitc brine tank.
1559252469 2016-09-09 UrbanProduction Wells No Violations I inspected this well location as part of on-going work-over activity intended to replace the plunger lift production system with a pumping unit. At the time of this inspection, the plunger lift system has been removed and roads and tubing were installed pending placement of the pumping unit. I noted that there was some gas leakage around the casing head packing, and I called and notified Jim Gessel with Green Energy, who provides contract well service for this unit.
1735268112 2013-07-24 UrbanProduction Wells Violations Noted The producing unit consists of a wellhead with mechanical plunger-lift unit and above-ground storage tank (AST) battery. The wellhead is located in a chain-link enclosure which is locked. The well is currently producing. There is ID at the wellhead. I did not observe any signs of leakage or problems. The AST battery is comprised of one 140-barrel production tank, one 50-barrel brine tank, and mechanical separator in a chain-link enclosure. There is a unit ID at the wellhead. Secondary containment is good. The unit is lacking safety equipment in accordance with 1501:9-9-05E. I advised Green Energy that the safety gear should be addressed before the start of school.
1789244959 2018-07-13 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The battery and wellhead were in separate chain-link enclosures which were locked and secure. The former plunger-lift system had been replaced with a pump jack. The well was in production. The fittings and connections were secure. The load-lines were locked. Secondary containment at the battery was present and intact and dry.
1968404325 2016-08-29 Work Over Reconditioning No Violations I inspected this well location pursuant to on-going work-over being conducted by Green Energy for Gilmour Academy. The well contractor was Hagen Well Service. At the time of this inspection, crews were preparing to remove the wellhead which had been permanently welded to the 4.5-inch casing following a previous incident. The casing head was being removed by grinder saw. Crews had previously blown down the well and had assembled and flexible line to allow gas to vent away from the well during grinding. The crews had stationed a fire watch person with fire extinguisher during this activity. The wellhead was successfully removed and the crews transitioned to begin removing production tubing. Following the removal of tubing, the crews will install pumping rods and a low-profile pumping unit. I met with both Jim and Gessel of Green Energy and a member of the Gilmour Academy maintenance staff to disuss planned activities.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0761393691 US-OH-128656 2014-12-19 OPERATIONMAINTANCE (a-c)
1735268112 US-OH-117234 2015-02-05 TANKS (a-i)

For data sources see[9]

References