34-035-20047

Well Details

Well ID: 34-035-20047
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: HISTORIC OWNER
Well Pad ID:
Farm/Lease Name: SOCIETY FOR SAVINGS
License Status: Orphan Well - Pending
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1939-08-19
Well Total Depth: 2836.00 ft
Configuration: Vertical
Latitude: 41.550000
Longitude: -81.440000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1939-08-19 QUAD=MENTOR 400M 1/2 HR. S.I. 379 M.
Reached Total Depth 1939-08-19 QUAD=MENTOR 400M 1/2 HR. S.I. 379 M.
Changed to Orphan Well Pending 2019-03-25 Changed Well To Orphan Pending
Record Last Modified 2019-03-25 QUAD=MENTOR 400M 1/2 HR. S.I. 379 M.

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 1000 Gal 0 R.P. 24 HRS.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0452974102 2014-06-23 Orphan No Violations I inspected this location pursuant to previous reports of gas odor. The gas odor complaints seem to coincide with the recent municipal construction of a walking path and pedestrian tunnel. I walked the area and could not detect any odors or detect gases with hand-held meter. Continued periodic surveillance is advised.
1394643060 2014-03-03 Field Inspected, Well Not Found No Violations I inspected the area where this well is suspected to be pursuant to a complaint. The well may be in the area where some recent earth work has been performed as part of a trail project by the City of Mayfield. A faint gas odor was apparent from time to time, but a high enough concentration to register on the gas meter. Owing to the heavy snow cover, attempts to locate the well were not successful. I will follow-up when snow melts and a better assessment can be made.
1900054990 2015-12-08 Orphan No Violations I inspected this well location pursuant to a complaint of gas odor which has been noted at various times near the walking trail area near here. At the time of this inspection, I noted the following visible elements: a 12-inch steel casing riser which extends 12 inches above grade, in an otherwise isolated, and wooded area. Sealed concentrically with cement within the casing is a 2-inch diameter pipe, the annulus of which was open to the extent that is visible. The top of the 2-inch pipe terminates within 3 inches of the larger casing. I recorded sustained readings of 10% LEL at the opening of the 2-inch pipe. The inferred wellhead is located within a larger cement pad, or vault-type structure, the purpose of which is not known. Following inspection, I spoke with a grounds and service professional (Brian Smith) from Progressive Insurance, which owns the property on which this well is located. We agreed to meet and discuss my inspection and management options.
1992985495 2005-05-17 Orphan No Violations inspected site with developer looked at old well on property 10 casing and 6 water well .
452974102 2014-6-23 0:00: OR No Violations