34-031-22309

Well Details

Well ID: 34-031-22309
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Lafayette Township
Operator Name: GRESS OIL & GAS
Well Pad ID:
Farm/Lease Name: TAYLOR ESTHER
License Status: Plugged and Abandoned
License Date: 2015-10-01
Spud Date: 1974-02-13
Spud Drilling Contractor:
Final Drill Date: 1974-02-21
Well Total Depth: 4215.00 ft
Configuration: Vertical
Latitude: 40.270000
Longitude: -81.760000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1974-02-13
Completed 1974-02-21
Reached Total Depth 1974-02-21
CO 1988-05-31 53 ATWOOD RESOURCES INC GeoDate 5/31/88
Unknown 1988-05-31 Issued Date 5/31/88 Expired Date 5/31/89 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
CO 1992-07-29 4327 SOUND ENERGY CO INC GeoDate 5/31/88
CO 1996-01-31 53 ATWOOD RESOURCES INC
CO 1996-01-31 5378 GRESS OIL & GAS GeoDate 5/31/88
Plugged/Abandoned 2014-03-14
APP 2015-10-01 Proposed Formations:CLINTON, Issued Date:10/1/2015, Expired Date:9/30/2017 12:00:00 PM, Drilling unit acres:116.6, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2017-02-10
Construction Permit Expires 2017-09-30

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4048 4084 27
4048 4084 27
4048 4084 27

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 46000 Gal 45000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 COLUMBIA GAS TRANSMISSION LLC 143.00 0.00 0
1985 COLUMBIA GAS TRANSMISSION LLC 12.00 6.00 60
1986 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
1987 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
1991 ATWOOD RESOURCES INC 30.00 0.00 365
1992 SOUND ENERGY CO INC 0.00 0.00 0
1993 SOUND ENERGY CO INC 115.00 0.00 120
1994 SOUND ENERGY CO INC 175.00 0.00 365
1995 SOUND ENERGY CO INC 218.00 0.00 365
1996 GRESS OIL & GAS 928.00 65.00 365
1997 GRESS OIL & GAS 0.00 0.00 0
1998 GRESS OIL & GAS 83.00 0.00 61
2000 GRESS OIL & GAS 0.00 0.00 0
2001 GRESS OIL & GAS 0.00 0.00 0
2002 GRESS OIL & GAS 38.00 0.00 31
2003 GRESS OIL & GAS 168.00 0.00 365
2004 GRESS OIL & GAS 0.00 0.00 0
2005 GRESS OIL & GAS 0.00 0.00 0
2006 GRESS OIL & GAS 0.00 0.00 0
2007 GRESS OIL & GAS 0.00 0.00 0
2008 GRESS OIL & GAS 0.00 0.00 0
2009 GRESS OIL & GAS 0.00 0.00 0
2010 GRESS OIL & GAS 0.00 0.00 0
2011 GRESS OIL & GAS 0.00 0.00 0
2012 GRESS OIL & GAS 0.00 0.00 0
2013 GRESS OIL & GAS 0.00 0.00 0
2014 GRESS OIL & GAS 0.00 0.00 0
2015 GRESS OIL & GAS 0.00 0.00 0
2016 GRESS OIL & GAS 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
1985 COLUMBIA GAS TRANSMISSION LLC Brine 0 60
1986 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
1987 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
1991 ATWOOD RESOURCES INC Brine 0 365
1992 SOUND ENERGY CO INC Brine 0 0
1993 SOUND ENERGY CO INC Brine 0 120
1994 SOUND ENERGY CO INC Brine 0 365
1995 SOUND ENERGY CO INC Brine 70 365
1996 GRESS OIL & GAS Brine 0 365
1997 GRESS OIL & GAS Brine 0 0
1998 GRESS OIL & GAS Brine 0 61
2000 GRESS OIL & GAS Brine 0 0
2001 GRESS OIL & GAS Brine 0 0
2002 GRESS OIL & GAS Brine 0 31
2003 GRESS OIL & GAS Brine 0 365
2004 GRESS OIL & GAS Brine 0 0
2005 GRESS OIL & GAS Brine 0 0
2006 GRESS OIL & GAS Brine 0 0
2007 GRESS OIL & GAS Brine 0 0
2008 GRESS OIL & GAS Brine 0 0
2009 GRESS OIL & GAS Brine 0 0
2010 GRESS OIL & GAS Brine 0 0
2011 GRESS OIL & GAS Brine 0 0
2012 GRESS OIL & GAS Brine 0 0
2013 GRESS OIL & GAS Brine 0 0
2014 GRESS OIL & GAS Brine 0 0
2015 GRESS OIL & GAS Brine 0 0
2016 GRESS OIL & GAS Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1077632638 2016-12-28 0:00 FR No Violations 1.50
-1408814585 2016-3-17 0:00: PB No Violations 1.00
-1642396777 2016-3-11 0:00: PW No Violations 0.50
-1814139092 2015-12-9 0:00: PW No Violations 2.00
-1960142860 2016-5-19 0:00: FR No Violations 0.50
-2101969194 2016-7-22 0:00: FR No Violations 0.50
-412367817 2016-12-1 0:00: FR No Violations 2.00
-644231502 2015-2-11 0:00: PW No Violations
-706311174 2015-8-18 0:00: PW No Violations
-944604565 2017-4-5 0:00:0 FR No Violations 0.50
0412367817 2016-12-01 Final Restoration No Violations On the day of my inspection I found that the exposed section of 3 inch plastic flow line was still in place. The 1 inch steel riser was also still in place. I called Jeff Gress, who claimed that he though MFC had already taken care of the flow line. He said that he would call them again. I called MFC and spoke with Jim Aslinides. He claimed that they have a right of way for the 3 line that runs from the Taylor tank battery site north to US 36, where their Levingood wells are. He said that the line is currently inactive, but they may need to use it in the future. Jim said that it used to run to a Columbia Gas substation in West Lafayette, but they had it plumbed into Gresss tank battery so he could sell gas into their line. I suggested that they reconnect the line to the substation and bury it so it is in place for future use. He said that he would have someone out to look at it. Gress also claimed that the steel riser was part of a drip on Gathercos sales line, which now belongs to Aspire Energy. There is also a meter run for a main sales line that now belongs to Aspire. I called Aspire Energy and spoke with Nichole. I requested that any equipment that is no longer in use be removed. I gave her the road directions and GPS coordinates for the equipment. She said that she would pass the information on to a technician so he could go out to look at the equipment, and they would get back to me.
0644231502 2015-02-11 Production Wells Violations Noted On the day of my inspection I found that the well was equipped with a swab head and a 4.5 to 2 swage. The valves were closed. The tank battery consisted of one 100 barrel tank, a vertical separator and a meter box. The identification sign was blank. The entire tank battery and wellhead were heavily overgrown with small trees and thick brush. This well and tank battery were in a state of abandonment. This well has not produced since 2003. This well must be plugged and abandoned within 180 days of the issuance of this compliance notice.
0706311174 2015-08-18 Production Wells No Violations On the day of my inspection I found that the well was still sitting idle. The wellhead was still equipped with a swage and the valves were still closed. The well and tank production equipment was still heavily overgrown with small trees and thick brush. The thicket of brush was surrounded by corn at the time of my inspection. I found no evidence of vehicle or foot traffic leading to the well or tanks. I called Gress Oil & Gas. I was told that they were trying to sell the well, but the deal fell through and they were allegedly applying for a plugging permit now.
0944604565 2017-04-05 Final Restoration No Violations On the day of my inspection I found that there had been no change at the site. I called Dwayne McElhaney with MFC to ask what they were going to do. He said that they had been given the order to reconnect the gas transmission line to the meter run and start selling gas into the system again. Dwayne said that it was on his list of things to do, but he has not had time to get out there yet. I told Dwayne that they need to make an effort to get the work done before crops are planted. He agreed to call me when they would be out there.
1077632638 2016-12-28 Final Restoration No Violations On the day of my inspection I found that the flow lines and meter run were still in place. I called Dwayne with Coshocton Pipeline to ask if he had received an order from MFC to take care of the flow line. Dwayne said that he had not been out yet and we discussed burying the flow line. He also commented that they may be looking into tying in with the Aspire Energy sales line at the meter run. I called Aspire to get an update on the status of the meter run. I spoke with Nichole again and she said that she had forwarded the information I gave her in our previous conversation to her operations group, but she has not received a response. She said that she would reach out again. I was contacted by Kevin from Aspires field operations. He said that he would call me next week to meet at the site and look at the equipment in question.
1408814585 2016-03-17 Plug / Plug Back No Violations On the day of my inspection I found that the pit had been closed and the soil graded out. The separator had been removed from the site. The 100 barrel tank had been drained and moved out to the road. There was still a 1 steel drip riser and 3 plastic flow line at the tank battery site. There is a sales line meter run and drip in the tree line where the tank battery was. Jeff Gress claimed that it was not his equipment; it was Gatherco and now belonged to Aspire Energy. I called Jeff and he said that the flow line that runs across the agricultural field south from US 36 is owned by MFC Drilling where they used to sell into Gatherco, and Jim Aslinides use to let him sell into that line. I advised Jeff that they need to look into a landowner waiver for the flow line.
1457974708 2016-03-14 Plug / Plug Back No Violations On the day of my inspection Formation Cementing bull-headed a 15 sack cement bottom plug through the 2.875 casing. Jet Wireline Services shot the 2.875 casing off at 2892. RB Drilling pulled the casing up to 2834. Formation pumped a 200 cement plug at the top of the Big Lime. Circulation was established prior to pumping the plug, and it was maintained throughout the plug. RB Drilling pulled the casing up to 892. Formation pumped a 179 cement plug through the Berea. Circulation was established prior to pumping the plug, and maintained throughout the plug. There was a discrepancy as to the depth of the surface casing. The plugging permit and completion report showed 579, but the original cement ticket from Halliburton and the cement report from the ODNR inspector Frank Meiser showed 470. Jeff Gress produced a log that also showed the bottom of the casing at 470. RB Drilling pulled up to 570. Formation pumped a 200 cement plug at the base of the surface casing. Circulation was established prior to pumping the plug and maintained throughout the plug. RB Drilling pulled the casing up to 200. Formation broke circulation and pumped until cement was circulated to surface. I monitored the cement surface plug for 1.25 hours and found that it did not drop. Jeff Gress cut the surface casing off at 36 below grade and capped it with a steel plate inscribed with the permit number.
1483463674 2017-01-03 Final Restoration No Violations On the day of my inspection I met with Jeff Sturgill, field technician for Aspire Energy, to look at the remaining equipment at the former well site. Jeff determined that the meter run belonged to MFC Drilling and it has not been in use since 2006. The meter run tied in with Aspires 2 inch sales line that runs to the Columbia Gas town border station for West Lafayette. Jeff also determined that the 2 inch line was active and being supplied from permits 2232 and 4423. Jeff closed the surface valve from the sales line to the meter run. He said that the producer (MFC Drilling) is responsible for all of the equipment from the flange back, which includes a circle chart box, a vertical drip and a series of valves and steel lines. Jeff also examined the 1 inch riser and said that it was connected directly to the sales line. He reviewed his area maps and found that there was not an underground gate valve anywhere near the equipment. He said that the only way to remove the equipment and cap the connections underground would be to shut the whole line down. He said that it might be possible in the summer, when the towns gas use is at an annual low. I contacted Dwayne McElhaney of Coshocton Pipeline, excavating contractor for MFC, to report what I had found.
1642396777 2016-03-11 Production Wells No Violations Jeff Gress notified me that a service rig was scheduled to move in on this well on 3/10/16. On the day of my inspection I found that a service rig had not moved in. The small trees around the well and tank battery had not been cleared. No attempt had been made to begin plugging operations.
1814139092 2015-12-09 Production Wells No Violations On the day of my inspection I found that the well was still shut in. The brush around the wellhead and tank battery was still overgrown. I called Jeff Gress. He claimed that he was trying to get a plugging contractor and he intended to get the well plugged this winter. I reminded him that the well was supposed to be plugged by 8/11/15 and told him that he must get the well plugged as soon as possible. I took updated photos. There were no leaks or spills.
1960142860 2016-05-19 Final Restoration No Violations On the day of my inspection I found that the 100 barrel tank had been removed. The gas line riser and flow line was still in place. The well site had been recently plowed for agricultural crops. I called Jeff Gress. He claimed that he was trying to contact the landowner, but he maintained that the riser belonged to Aspire Energy. He also claimed that he would contact MFC to remove the exposed section of flow line. I will try to get in touch with Aspire Energy about removing the riser.
2101969194 2016-07-22 Final Restoration No Violations On the day of my inspection I found that the field where the well was located was growing in corn that was over 5 feet tall. I could not see the actual site. The access road had been plowed, planted and incorporated in to the agricultural crop field.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0644231502 US-OH-127301 2016-05-04 Well shall be plugged

For data sources see[9]

References