34-029-60782

Well Details

Well ID: 34-029-60782
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Fairfield Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: WHAN SIMON
License Status: Storage Well
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1925-01-31
Well Total Depth: 863.00 ft
Configuration: Vertical
Latitude: 40.820000
Longitude: -80.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1925-01-31
Reached Total Depth 1925-01-31
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2013-03-11

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 R.P. 96 HRS.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1520374301 2015-4-29 0:00: SO No Violations
-1523925859 2013-5-9 0:00:0 SO No Violations
-1837336483 2019-4-11 0:00: SO No Violations
-2043701281 2017-3-9 0:00:0 SO No Violations 0.40
0556248710 2014-11-05 Storage Well No Violations I inspected Columbia Gas storage well #3645. The well is equipped with a master gate valve and a side gate valve. There was no storage tank associated with the well. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stable. No violations found.
0949398536 2018-03-19 Storage Well No Violations The purpose of my inspection was to conduct a status check inspection on well #6-0782. Access to the well remained stable and drivable. Correct identification was present at the well. The surface casing was above grade. Annular ports were closed to atmosphere. The production casing was equipped with a master gate valve and a wing valve. A 4.5 run connected the wing valve to a buried drip before the lead line. A domestic supply connection was present. No leaks were observed. No violations were observed during this inspection.
1000145451 2020-1-23 0:00: SO No Violations 1.00
1520374301 2015-04-29 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1523925859 2013-05-09 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 3645 today. The well is located in Section 31, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
1549896704 2019-02-11 Storage Well No Violations This storage well was equipped with a flanged well head with a master gate valve and a side gate valve. A domestic connection was present. No leaks were observed at the time of inspection. The access road was stable. Proper identification was posted.
1769547197 2016-02-02 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1837336483 2019-04-11 Storage Well No Violations I was on location to check this storage well with Columbia Gas and US Department of Transportation personnel during a PHMSA (Pipeline and Hazardous Materials Safety Administration) audit of the Brinker field. The well was equipped with a 5k API wellhead with one master valve. The annular pressure was gauged and read one psi. The tubing pressure read 158 psi. Proper identification was posted. The access road was stable. I observed no violations at the time of inspection.
2043701281 2017-03-09 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #6-0782. Lease access was through a graveled farm driveway. The well location was stable with well-established vegetation. Correct and legible identification was posted at the well head. The well head annular side ports contained a closed and plugged valve in each side. A master gate valve was plumbed to the top of the well head. A side gate valve was plumbed out of the side of the master gate valve. A 4 flow line was plumbed out of the side gate valve to a buried drip tank. Test valves were closed and plugged. No audible or visual leaks were detected. No violations were observed during this inspection.
230519419 2019-10-22 0:00 SO No Violations 1.00
556248710 2014-11-5 0:00: SO No Violations 0.30
949398536 2018-3-19 0:00: SO No Violations 0.20

For data sources see[4]

References