Well History

Well Status Well Status Date Comment
Completed 1916-01-01
Reached Total Depth 1916-01-01
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-133251293 2016-11-22 0:00 SO No Violations
-1475804712 2013-5-30 0:00: SO No Violations
-1795595309 2019-10-1 0:00: SO No Violations 1.00
-2143918907 2017-10-4 0:00: SO No Violations 0.30
-567063748 2020-1-23 0:00: SO No Violations 1.00
-731072953 2015-9-2 0:00:0 SO No Violations
0133251293 2016-11-22 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0174054077 2014-11-07 Storage Well No Violations I inspected Columbia Gas storage well #4597. The well is equipped with a master gate valve and a side gate valve. The pipe size was 3 from the side valve to the drip tank. There was no storage tank associated with the well. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stable. No violations found.
0731072953 2015-09-02 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1455561270 2018-10-04 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #6-0338. Access to the well remained drivable and stable. Correct identification was present. The surface casing annulus was plumbed above grade and open to atmosphere. The production casing annulus was closed to atmosphere. The production casing was equipped with a master gate valve that was topped with a flow tee. The tee contained a blind flange on one side and the other contained a wing valve. The wing valve was connected to a 4.5 run that lead to a buried drip prior to the distribution system. All valves were closed. No leaks were observed. No violations were observed during this inspection.
1475804712 2013-05-30 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4597 today. The well is located in Section 32, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
174054077 2014-11-7 0:00: SO No Violations 0.30
2143918907 2017-10-04 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #6-0338. The lease access and well location were stable. Correct identification was present. Annular valves were closed and plugged. The well casing was equipped with a master gate valve and side gate valve. The side gate valve was plumbed out to a buried drip. No leaks were observed. No violations were observed during this inspection.

For data sources see[3]