34-029-60324

Well Details

Well ID: 34-029-60324
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Fairfield Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: COFFMAN RUSSELL W
License Status: Storage Well
License Date: 1964-01-02
Spud Date: 1964-01-09
Spud Drilling Contractor:
Final Drill Date: 1964-02-24
Well Total Depth: 962.00 ft
Configuration: Vertical
Latitude: 40.820000
Longitude: -80.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1964-01-09
Completed 1964-02-24
Reached Total Depth 1964-02-24
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 R.P. 72 HRS.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-186127370 2019-10-18 0:00 SO No Violations 1.00
-702578920 2016-5-3 0:00:0 SO No Violations
-92883132 2020-1-23 0:00: SO No Violations 1.00
0105651997 2013-05-30 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4817 today. The well is located in Section 33, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a needle valve. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
0702578920 2016-05-03 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve only. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
105651997 2013-5-30 0:00: SO No Violations
1525869222 2018-05-09 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #6-0324. Lease access was through an agricultural road that was stable and drivable. The well location was stable with well-established vegetation. Correct and legible identification was present at the well. The 4.5production casing was equipped with a 4.5 X 2 swage and 2 valve in the open position. The 2 valve contained a 2 X 0.5 swage and 0.5 valve that was closed and plugged. No audible or visual leaks were detected. No violations were detected during this inspection.
1622555533 2014-11-25 Storage Well No Violations I inspected Columbia Gas Transmission gas well #4817. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The annulus valve is plumbed up and closed. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1873120423 2015-09-24 Storage Well No Violations I conducted a status check on this well. The well is equipped with casing plumbed into a Swage nipple valve into a 2 inch gate valve and topped with a plug. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
2036669067 2017-03-06 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #6-0324. Lease access was through an agricultural road that was stable and drivable. The well location was stabilized with well-established vegetation. Correct and legible identification was present at the well. The 4.5production casing was equipped with a 4.5 X 2 swage and 2 valve in the open position. The 2 valve contained a 2 X 0.5 swage and 0.5 valve that was closed and plugged. No audible or visual leaks were detected. No violations were detected during this inspection.