If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-029-21750 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.82,"lon":-80.84,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Salem Township | |
Operator Name: EAP OHIO LLC | |
Well Pad ID: US-OH-000443 | |
Farm/Lease Name: ROY D 31-15-3 | |
License Status: Producing | |
License Date: 2012-09-27 | |
Spud Date: 2012-12-05 | |
Spud Drilling Contractor: NOMAC DRILLING CORP | |
Final Drill Date: 2012-12-24 | |
Well Total Depth: 12664.00 ft | |
Configuration: Horizontal | |
Latitude: 40.820000 | |
Longitude: -80.840000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-09-27 | Proposed Formations:POINT PLEASANT, Issued Date:9/27/2012, Expired Date:9/27/2014 12:00:00 PM, Drilling unit acres:153.2, Proposed Well Type:OG, Proposed Well Class:EDPW |
Correction to Well | 2012-10-05 | CORRECTION TO X,Y COORDINATES (SURFACE & TARGET). |
Reached Total Depth | 2012-12-24 | |
Correction to Well | 2013-03-22 | CORRECTION TO SURFACE FOOTAGE & TARGET INFORMATION: FOOTAGE & X,Y COORDINATES FROM AS DRILLED SURVEY PLAT. UNIT SIZE CHANGE TO 119.46 ACRES. |
Correction to Well | 2013-06-21 | UNIT SIZE CHANGED TO 119.42 ACRES. |
Completion Report Received | 2014-06-05 | |
Construction Permit Expires | 2014-09-27 | |
Record Last Modified | 2017-10-23 |
For data sources see[2]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 04/30/2013 | 05/03/2013 | 7862 | 3,691,840.0 | 294257 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | 100 Mesh Sand | PERFORMANCE TECHNOLOGIES | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 1.34645 | 0 |
Fresh Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 73.5003 | 0 | |
PTLFR200 | PERFORMANCE TECHNOLOGIES | Friction Reducer | Proprietary Aliphatic Hydrocarbon | TRADE SECRET | 30 | 0.01317 | 0 | |
Proprietary Oxyalkylated Alcohol | TRADE SECRET | 5 | 0.00219 | 0 | ||||
PTLIS352 | PERFORMANCE TECHNOLOGIES | Iron Control Agent | Citric Acid | 000077-92-9 | 100 | 0.00057 | 0 | |
PTLBW102 | PERFORMANCE TECHNOLOGIES | Breaker | Ammonium Persulfate | 007727-54-0 | 100 | 0.001 | 0 | |
Recycled Produced Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 10.6632 | 0 | |
PTLSI372 | PERFORMANCE TECHNOLOGIES | Scale Inhibitor | No Hazardous Components | NONE | 0 | 0 | 0 | |
PTLBW112 | PERFORMANCE TECHNOLOGIES | Breaker | Ammonium Persulfate | 007727-54-0 | 100 | 0.00709 | 0 | |
EC6111A | NALCO | Anti-Bacterial Agent | Glutaraldehyde (Pentanediol) | 000111-30-8 | 30 | 0.01233 | 0 | |
Water | 007732-18-5 | 0 | 0.04325 | 0 | ||||
PTLCA102 | PERFORMANCE TECHNOLOGIES | Cross Linker | Proprietary Inorganic Salt | TRADE SECRET | 30 | 0.00441 | 0 | |
Proprietary Alkyl Alcohol | TRADE SECRET | 60 | 0.00883 | 0 | ||||
Sodium Hydroxide | 001310-73-2 | 60 | 0.00883 | 0 | ||||
PTLAI171, PTLBW112, PTLFR200, PTLGL140, PTLSI372 | PERFORMANCE TECHNOLOGIES | Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, Scale Inhibitor | Proprietary Substituted Fatty Acid Ester | TRADE SECRET | 0 | 0.04567 | 0 | |
Proprietary Methanol | TRADE SECRET | 0 | 0.00077 | 0 | ||||
Proprietary Clay | TRADE SECRET | 0 | 0.13961 | 0 | ||||
Proprietary Alkylene Oxide Block Polymer | TRADE SECRET | 0 | 0.00077 | 0 | ||||
Guar Gum | 009000-30-0 | 0 | 0.13961 | 0 | ||||
2-Ethylhexanol | 000104-76-7 | 0 | 0.00077 | 0 | ||||
Proprietary Surfactant | TRADE SECRET | 0 | 0.13961 | 0 | ||||
Sodium Chloride | 007647-14-5 | 0 | 0.04567 | 0 | ||||
Copper Sulfate | 007758-98-7 | 0 | 0.00051 | 0 | ||||
Proprietary Oxyalkylated Fatty Acid Derivative | TRADE SECRET | 0 | 0.04567 | 0 | ||||
Tetrasodium Ethylenediaminetetraacetate | 000064-02-8 | 0 | 0.04567 | 0 | ||||
Proprietary Aliphatic Alcohol | TRADE SECRET | 0 | 0.04567 | 0 | ||||
Diethylene Glycol | 000111-46-6 | 0 | 0.00077 | 0 | ||||
Proprietary Polycarboxylic Acid Polymer | TRADE SECRET | 0 | 0.01854 | 0 | ||||
Proprietary Vinyl Copolymer | TRADE SECRET | 0 | 0.04899 | 0 | ||||
Petroleum Distillate Hydrotreated Light | 064742-47-8 | 0 | 0.13961 | 0 | ||||
Water | 007732-18-5 | 0 | 0.06498 | 0 | ||||
PTLMP136 | PERFORMANCE TECHNOLOGIES | Acid | Water | 007732-18-5 | 85 | 0.94953 | 0 | |
Hydrochloric Acid | 007647-01-0 | 15 | 0.16756 | 0 | ||||
Northern White Sand | PERFORMANCE TECHNOLOGIES | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 13.1275 | 0 | |
PTLAI171 | PERFORMANCE TECHNOLOGIES | Corrosion Inhibitor | Ethylene Glycol | 000107-21-1 | 30 | 0.00056 | 0 | |
Proprietary Organic Amine Resin Salt | TRADE SECRET | 30 | 0.00056 | 0 | ||||
Proprietary Quaternary Ammonium Compound | TRADE SECRET | 10 | 0.00019 | 0 | ||||
Isopropanol (Isopropyl Alcohol, Propan-2-ol) | 000067-63-0 | 60 | 0.00112 | 0 | ||||
Proprietary Aromatic Aldehyde | TRADE SECRET | 10 | 0.00019 | 0 | ||||
Dimethyl Formamide | 000068-12-2 | 10 | 0.00019 | 0 | ||||
PTLGL140 | PERFORMANCE TECHNOLOGIES | Gelling Agent | No Hazardous Components | NONE | 0 | 0 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-05-02 | H2O | 15 | 5929 Bbl | 386140 | Performance Technologies | STAGE 13
36 SHOTS |
2013-05-01 | H2O | 15 | 6885 Bbl | 381120 | Performance Technologies | STAGE 5
36 SHOTS |
2013-04-30 | H2O | 15 | 6408 Bbl | 379740 | Performance Technologies | STAGE 1
36 SHOTS |
2013-05-02 | H2O | 15 | 6046 Bbl | 386560 | Performance Technologies | STAGE 12
36 SHOTS |
2014-05-02 | H2O | 15 | 5903 Bbl | 387380 | Performance Technologies | STAGE 9
36 SHOTS |
2013-05-03 | H2O | 15 | 5862 Bbl | 386150 | Performance Technologies | STAGE 14
36 SHOTS |
2013-05-01 | H2O | 15 | 6248 Bbl | 384736 | Performance Technologies | STAGE 7
36 SHOTS |
2013-05-02 | H2O | 15 | 6192 Bbl | 380340 | Performance Technologies | STAGE 10
36 SHOTS |
2013-05-01 | H2O | 15 | 5680 Bbl | 382640 | Performance Technologies | STAGE 4
36 SHOTS |
2013-05-02 | H2O | 15 | 6862 Bbl | 379740 | Performance Technologies | STAGE 8
36 SHOTS |
2013-04-30 | H2O | 15 | 6248 Bbl | 382580 | Performance Technologies | STAGE 3
36 SHOTS |
2013-05-01 | H2O | 15 | 5606 Bbl | 381940 | Performance Technologies | STAGE 6
36 SHOTS |
2013-04-30 | H2O | 15 | 6239 Bbl | 379120 | Performance Technologies | STAGE 2
36 SHOTS |
2013-05-02 | H2O | 15 | 6397 Bbl | 386560 | Performance Technologies | STAGE 11
36 SHOTS |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | CHESAPEAKE EXPLORATION LLC | 718551 | 7557 | 294 |
2015 | CHESAPEAKE EXPLORATION LLC | 551631 | 3818 | 363 |
2016 | CHESAPEAKE EXPLORATION LLC | 388864 | 1832 | 365 |
2017 | CHESAPEAKE EXPLORATION LLC | 310149 | 1125 | 365 |
2018 | CHESAPEAKE EXPLORATION LLC | 257991 | 547 | 364 |
2019 | CHESAPEAKE EXPLORATION LLC | 56831 | 268 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | CHESAPEAKE EXPLORATION LLC | Brine | 6047 | 294 |
2015 | CHESAPEAKE EXPLORATION LLC | Brine | 2884 | 363 |
2016 | CHESAPEAKE EXPLORATION LLC | Brine | 1830 | 365 |
2017 | CHESAPEAKE EXPLORATION LLC | Brine | 1327 | 365 |
2018 | CHESAPEAKE EXPLORATION LLC | Brine | 1143 | 364 |
2019 | CHESAPEAKE EXPLORATION LLC | Brine | 799 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1177930132 | 2012-9-13 0:00: | SC | No Violations | |
-1601422631 | 2012-12-4 0:00: | DD | No Violations | |
-1887554950 | 2012-10-15 0:00 | DD | No Violations | |
-1889816396 | 2013-7-2 0:00:0 | PL | No Violations | |
-441305200 | 2013-4-9 0:00:0 | DD | No Violations | |
-562621678 | 2012-12-12 0:00 | DD | No Violations | |
-730818307 | 2012-10-14 0:00 | DD | No Violations | |
-768729594 | 2014-5-19 0:00: | PL | No Violations | 2.00 |
-920189640 | 2012-10-24 0:00 | DD | No Violations | |
-947722342 | 2016-3-2 0:00:0 | PW | No Violations | 0.50 |
0009471531 | 2012-12-26 | Drill / Deepen / Reopen | No Violations
-Tex Pumping LLC was the cementing contractor. There was good fluid circulation throughout the cementing operation. The cement job was done in stages. Following two spacers designed to recover the oil-based mud used to drill the hole and condition the hole, respectively, the tail cement slurry was pumped. O-Tex pumped 443 bbls of tail cement at 15.3 pounds per gallon (ppg). The plug was dropped, and displaced with 279 bbls of water. The plug bumped the float collar at 11:37pm on 12/26/2012. Pressure held. The float held when the pressure was released, and 3.0 bbls of water bled back. | |
0312237210 | 2012-10-15 | Drill / Deepen / Reopen | No Violations | I was on site for the cementing of the conductor for this well location with Rick Anderson. I witnessed cement come back to surface. The pad is in good condition and there are no violations at this time. |
0441305200 | 2013-04-09 | Drill / Deepen / Reopen | No Violations | I went to the site for a status check and found that the site was being prepared for well stimulation. A number of frac tanks were present on site, and a water pumping set-up was present on Depot Road where it intersects Cold Run Creek. A crew was installing a security camera. No one else was present. |
0562621678 | 2012-12-12 | Drill / Deepen / Reopen | No Violations
-Tex Pumping LLC was the cementing contractor. There was good fluid circulation throughout the cementing operation. The cement was mudscaled at 15.5 pounds per gallon (ppg), and adjusted to 15.6 ppg. O-Tex pumped 146 bbls of cement slurry at 15.6 ppg. Cement returns to the surface were observed. An estimated 13 bbls of cement returned to the surface. Cement returns were mudscaled at 13.0 ppg. The plug was displaced with 133 bbls of water. During the plug displacement, the plug did not bump the float collar when the calculated displacement plus half the volume of the shoe track was reached, so pumping was discontinued. The displacement was completed at 11:36am on 12/12/2012. The float held when the pressure was released and 0.5 bbls of water bled back. | |
0599667445 | 2012-12-08 | Drill / Deepen / Reopen | No Violations | I was at the site to witness the top--Tex Pumping LLC was the cementing contractor. O-Tex mixed and mudscaled the cement, and pumped 57 bbls of cement slurry at 15.6 pounds per gallon (ppg). Cement returns to the surface were observed. Approximately 3 bbls of cement returned to the surface. Following a 2.5 hour wait, the cement top had fallen approximately 29.5 feet. O-Tex pumped an additional 6 bbls of cement to bring the cement back to the surface. The job was complete at 1:05pm on 12/08/2012. |
0730818307 | 2012-10-14 | Drill / Deepen / Reopen | No Violations | |
0768729594 | 2014-05-19 | Preliminary Restoration | No Violations
-lined and sealed secondary containment. There are concrete barriers protecting the containment from vehicles. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators. There is a truck grounding area for trucks collecting condensate and/or produced water. There is also two compressors on this pad that is used for vapor recover from the production tanks. Along the interior of the chain link fence there is a site drain installed. Outlets are located at the east and west sides of the pad. Inside the fence, there is an earthen berm, with well-established ground cover. The soil stockpile is well stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. Preliminary restoration is complete and approved. | |
0920189640 | 2012-10-24 | Drill / Deepen / Reopen | No Violations | While enroute to other inspections, I stopped at the site to collect GPS data for the wellhead and access road. |
0947722342 | 2016-03-02 | Production Wells | No Violations | I was on location for a status check. My inspection found the access road gate locked and the access road is in good repair. An identification sign at the access road entrance, well, and tank battery. The pad is fenced and all man doors are locked. The #8H well is in production. The well is equipped with a plunger lift assembly. There is a steel dike around the tank battery.
The equipment on the pad consists of the following: 6 - Storage tanks 400 bbl 1 - Vapor recovery unit (VRU) 1 - Gas processing unit (GPU) 1 - Vertical separator 1 - Sand separator 1 - Thermal electric generator 1 - Producing well Site fenced and man doors locked |
1177930132 | 2012-09-13 | Surface Facility Construction | No Violations | I went to the site to review the construction process of the drilling pad. The pad was excavated, and the berms up. Preliminary soil stabilization has been completed. No stone in place at this time. There is a gate at the access road, but no fence around the pad yet. |
1293463694 | 2017-02-09 | Production Wells | No Violations | The purpose for my inspection was to conduct a status check on well #2-1750-00-00. RBDMS indicates the operator is current with reporting production. The lease entrance is marked with a sign board containing signs reporting required well identification and emergency response information. At the time of my inspection, the local area had received a coating of snow that partially covered the location. The lease road was drivable. No signs of erosion were observed adjacent to the road traveling back to the pad. The soil stockpile remains stable with well- |
1365613966 | 2012-08-07 | Surface Facility Construction | No Violations | I went to the site and conducted a pre-construction site inspection with Brett Bell, Chesapeake Field Representative. |
1365617476 | 2012-12-07 | Drill / Deepen / Reopen | No Violations
-Tex Pumping LLC was the cementing contractor. There was intermittent circulation during the cementing operation. O-Tex pumped 25 bbls of gel with Bero-sel ahead of the cement. The cement was mudscaled and pumped at 15.6 pounds per gallon (ppg). O-Tex pumped 177 bbls of cement slurry at 15.6 ppg. Circulation was restored when 45 bbls of the cement had been pumped. Circulation was lost again when 80 bbls of the cement had been pumped. Circulation returned when 156 bbls of cement had been pumped. Circulation continued until about 90 bbls into the displacement, when it stopped for the duration of the job. No cement returns to surface were observed. The plug was displaced with 101 bbls of water. The plug bumped the float collar at 5:52pm. O-Tex pressured up on the casing, and the pressure held. When the pressure was released, approximately 1.0 bbl of water flowed back. Since circulation was lost and there were no cement returns to surface, a bond log will be run to determine the depth of the top of the cement. | |
1460173683 | 2012-10-17 | Drill / Deepen / Reopen | No Violations | I went to the site to check the status of the cellar floor. Jimmy Freeman of Chesapeake indicated that it would be completed with redi-mix the next day. |
1601422631 | 2012-12-04 | Drill / Deepen / Reopen | No Violations | I went to the site and had a pre-spud meeting with drilling consultants Mike Kirkpatrick and Gene Belsom. Nomac 310 hopes to commence drilling on 12/05/2012. |
1857483223 | 2016-04-05 | Production Wells | No Violations | I was on location for a status check. My inspection found the access road gate locked and the
access road is in good repair. An identification sign at the access road entrance, well, and tank battery. The pad is fenced and all man doors are locked. The #8H well is in production. The well is equipped with a Christmas tree valve assembly. There is a steel dike around the tank battery. The equipment on the pad consists of the following: 6 - Storage tanks 400 bbl 1 - Vapor recovery unit (VRU) 1 - Gas processing unit (GPU) 1 - Sand separator 1 - Thermal electric generator 1 - Producing well Site fenced and man doors locked |
1887554950 | 2012-10-15 | Drill / Deepen / Reopen | No Violations | I witnessed the cementing of the conductor casing. Express Energy Services drilled a 26 diameter hole to 120. Express installed 120 of 20 OD casing. During drilling, water was encountered at an approximate depth of between 55 and 60. Allied Cementing Co., LLC was the cementing contractor. The cement was mudscaled at 16.2 pounds per gallon (ppg), and adjusted to 15.6 ppg. Allied pumped 47 bbls of cement slurry at 15.6 ppg. The cement was displaced with 40 bbls of water. Cement returns to surface were observed. An estimated 10 bbls of cement returned to surface. Displacement was completed at 8:47pm. |
1889816396 | 2013-07-02 | Preliminary Restoration | No Violations
-established ground cover. The soil stockpile is well stabilized with vegetation. Crops and/or woodlands are growing normally outside the fenced area and berm. The area of disturbance has good ground cover. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The well has a frac valve in place, but there is no production equipment at the site. The cellar is full water to the top. Preliminary restoration approval will not be finalized pending installation of production equipment. | |
2066086276 | 2020-1-10 0:00: | PW | No Violations | 1.00 |
312237210 | 2012-10-15 0:00 | DD | No Violations | 2.50 |
599667445 | 2012-12-8 0:00: | DD | No Violations | |
9471531 | 2012-12-26 0:00 | DD | No Violations |
For data sources see[9]