34-029-21749

Well Details

Well ID: 34-029-21749
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Fairfield Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-000338
Farm/Lease Name: LEHMAN 24-12-2
License Status: Temporary Inactive Status 4th Year
License Date: 2017-05-10
Spud Date: 2012-11-05
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2012-11-20
Well Total Depth: 14201.00 ft
Configuration: Horizontal
Latitude: 40.840000
Longitude: -80.640000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-09-20 Proposed Formations:TRENTON BLACK RIVER, Issued Date:9/20/2012, Expired Date:9/20/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2012-10-04 Proposed Formations:POINT PLEASANT, Issued Date:10/4/2012, Expired Date:10/4/2014 12:00:00 PM, Drilling unit acres:153.24, Proposed Well Type:OG, Proposed Well Class:
Correction to Well 2012-11-02 CORRECTION TO TARGET INFORMATION: X,Y COORDINATES, LAT/LONGS & ELEVATION.
Reached Total Depth 2012-11-20 WCR IN PRELIM FILE/TEMPORARY INACTIVE CHECKLIST REC'D FROM CO ON 03/22/2016/REC'D TA2 CHECKLIST 12/01/2016
Correction to Well 2013-03-22 CORRECTION TO TARGET INFORMATION: FOOTAGE & X,Y COORDINATES FROM AS DRILLED SURVEY PLAT. UNIT SIZE CHANGED TO 145.44 ACRES.
Correction to Well 2013-04-05 UNIT SIZE CHANGED TO 145.52 ACRES.
APP 2015-06-02 Proposed Formations:POINT PLEASANT, Issued Date:6/2/2015, Expired Date:6/1/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
APP 2017-05-10 Proposed Formations:POINT PLEASANT, Issued Date:5/10/2017, Expired Date:5/10/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:TI
Construction Permit Expires 2018-05-10 WCR IN PRELIM FILE/TEMPORARY INACTIVE CHECKLIST REC'D FROM CO ON 03/22/2016/REC'D TA2 CHECKLIST 12/01/2016
Record Last Modified 2019-05-15 WCR IN PRELIM FILE/TEMPORARY INACTIVE CHECKLIST REC'D FROM CO ON 03/22/2016/REC'D TA2 CHECKLIST 12/01/2016

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-07-18 8608 14062 432
8608 14062 432
8608 14062 432

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 03/05/2013 03/10/2013 8316 4,040,690.0 352051

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 PTLCA102 PERFORMANCE TECHNOLOGIES Cross Linker Sodium Hydroxide 001310-73-2 60 0.01855 0
Proprietary Inorganic Salt TRADE SECRET 30 0.00927 0
Proprietary Alkyl Alcohol TRADE SECRET 60 0.01855 0
PTLSI372 PERFORMANCE TECHNOLOGIES Scale Inhibitor No Hazardous Components NONE 0 0 0
PTLFR200 PERFORMANCE TECHNOLOGIES Friction Reducer Proprietary Oxyalkylated Alcohol TRADE SECRET 5 0.00201 0
Proprietary Aliphatic Hydrocarbon TRADE SECRET 30 0.01207 0
PTLBW112 PERFORMANCE TECHNOLOGIES Breaker Ammonium Persulfate 007727-54-0 100 0.00911 0
Northern White Sand PERFORMANCE TECHNOLOGIES Proppant - Natural Crystalline Silica (Quartz Sand, Silicon Dioxide) 014808-60-7 100 14.7754 0
PTLGL140 PERFORMANCE TECHNOLOGIES Gelling Agent No Hazardous Components NONE 0 0 0
EC6111A NALCO Anti-Bacterial Agent Water 007732-18-5 0 0.02564 0
Glutaraldehyde (Pentanediol) 000111-30-8 30 0.00716 0
PTLAI171 PERFORMANCE TECHNOLOGIES Corrosion Inhibitor Proprietary Organic Amine Resin Salt TRADE SECRET 30 0.00075 0
Ethylene Glycol 000107-21-1 30 0.00075 0
Isopropanol (Isopropyl Alcohol, Propan-2-ol) 000067-63-0 60 0.0015 0
Proprietary Aromatic Aldehyde TRADE SECRET 10 0.00025 0
Dimethyl Formamide 000068-12-2 10 0.00025 0
Proprietary Quaternary Ammonium Compound TRADE SECRET 10 0.00025 0
PTLIS352 PERFORMANCE TECHNOLOGIES Iron Control Agent Citric Acid 000077-92-9 100 0.00058 0
Fresh Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 79.2405 0
100 Mesh Sand PERFORMANCE TECHNOLOGIES Proppant - Natural Crystalline Silica (Quartz Sand, Silicon Dioxide) 014808-60-7 100 1.4468 0
PTLBW102 PERFORMANCE TECHNOLOGIES Breaker Ammonium Persulfate 007727-54-0 100 0.00121 0
PTLMP136 PERFORMANCE TECHNOLOGIES Acid Water 007732-18-5 85 0.776 0
Hydrochloric Acid 007647-01-0 15 0.13694 0
Recycled Produced Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 3.32352 0
PTLAI171, PTLBW112, PTLFR200, PTLGL140, PTLSI372 PERFORMANCE TECHNOLOGIES Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, Scale Inhibitor Proprietary Substituted Fatty Acid Ester TRADE SECRET 0 0.04276 0
Proprietary Aliphatic Alcohol TRADE SECRET 0 0.04276 0
Sodium Chloride 007647-14-5 0 0.04276 0
Proprietary Methanol TRADE SECRET 0 0.00104 0
2-Ethylhexanol 000104-76-7 0 0.00104 0
Water 007732-18-5 0 0.06607 0
Proprietary Clay TRADE SECRET 0 0.20732 0
Petroleum Distillate Hydrotreated Light 064742-47-8 0 0.20732 0
Proprietary Polycarboxylic Acid Polymer TRADE SECRET 0 0.02227 0
Copper Sulfate 007758-98-7 0 0.00048 0
Proprietary Oxyalkylated Fatty Acid Derivative TRADE SECRET 0 0.04276 0
Tetrasodium Ethylenediaminetetraacetate 000064-02-8 0 0.04276 0
Proprietary Surfactant TRADE SECRET 0 0.20732 0
Guar Gum 009000-30-0 0 0.20732 0
Proprietary Vinyl Copolymer TRADE SECRET 0 0.04711 0
Diethylene Glycol 000111-46-6 0 0.00104 0
Proprietary Alkylene Oxide Block Polymer TRADE SECRET 0 0.00104 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-03-10 H2O 15 7723 Bbl 591500 Performance Technologies STAGE 12/12

36 SHOTS

2013-03-05 H2O 15 8230 Bbl 551280 Performance Technologies STAGE 1/12

36 SHOTS STAGES 2-11 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2019 CHESAPEAKE EXPLORATION LLC 0 0 0

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2019 CHESAPEAKE EXPLORATION LLC Brine 0 0

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1036433271 2016-2-26 0:00: PW No Violations
-1355995844 2012-11-14 0:00 DD No Violations
-1704832102 2018-11-20 0:00 PW No Violations 0.50
-1899253135 2012-10-4 0:00: SC No Violations
-2135977681 2016-12-6 0:00: PW No Violations
-449893159 2019-11-25 0:00 TI No Violations 1.00
-562527426 2014-6-17 0:00: PL No Violations 1.00
0313990817 2016-06-21 Production Wells No Violations My purpose for inspection was to conduct a second year temporary inactive well status inspection.

There is one well on the pad. The sign board posted at the lease entrance displayed signs with the well name, address, permit number and emergency contact information. The lease road was graveled and in good repair with a locked gate at State Route 7. Erosion and sedimentation controls were in place and ground cover was well established along the road. I walked the entire location and found the well pad constructed with an earthen berm perimeter in good repair, being stabilized with well-established vegetation. Erosion and sedimentation controls are in place and functioning. The well pad was found to be enclosed by a chain link fence with barbed wire at the top. The primary entrance and escape doors were found locked. The surface of the well pad consists of gravel and is in good repair. Soil stockpile is stabilized with well-established vegetation. The Lehman 8H was constructed with 120 of 20 conductor, 758 of 13 3/8 surface casing, 1527 of 9 5/8 intermediate casing and 14196 of 5 1/2 production casing. Drilling was completed 11/20/2012. The well was stimulated 3/5/2013 and completed with 7872 of 2 7/8 tubing. The well head was constructed with a Christmas tree valve assembly and found to be protected by a perimeter of steel cattle gates further protected by concrete Jersey barriers. Proper well identification signage was displayed. A cellar grate was in place to prevent falls. The cellar contained water with approximately 4 feet of freeboard. The production tubing and casing pressure gauges indicated 0 psi. Due to the position of the intermediate casing gauge, I was unable to determine what pressure the gauge was indicating. Also, the surface casing gauge was covered with debris preventing an accurate indication of pressure on the gauge. No sheen or leaking gas was observed on the water in the cellar. The mousehole was cemented. Gate

0538214919 2012-11-07 Drill / Deepen / Reopen No Violations
0562527426 2014-06-17 Preliminary Restoration No Violations I stopped by the site to check on the status of well completion and restoration. The well has been hydraulically fractured. There is no tanks or production unit at this time. The well is equipped with a Christmas tree. Values are locked out. I walked the entire site, and found the location to be in good condition. All erosion and sedimentation controls, and drainage controls appear to be functioning. Ground cover is well established along the access road and around the drilling pad. No areas of erosion are present. Preliminary restoration approval will not be finalized at this time.
0757675359 2013-08-20 Preliminary Restoration No Violations I reviewed the site to assess the completion of preliminary restoration. There is a sign board at the access road entry featuring the well name, permit number and emergency contact information. The access road has a padlocked gate near State Route 7. The access road is in good repair. Drainage and erosion controls were in place and appear to be functioning. Ground cover was well established along the access road. I found the drilling/production pad to be enclosed entirely with a chain link fence with barbed wire at the top, and with a padlocked gate. The pad has a crushed limestone surface, and is in good repair. The pad does have some ponded water along the perimeter. The fence is in good repair. Outside the fence, there is an earthen berm. I walked the exterior perimeter and noted that the berm is generally in good repair and ground cover is generally well established. There are some areas of the berm that do not have much ground cover due to being shaley with little soil. Most of the area of disturbance has good ground cover. The soil stockpile is well stabilized with vegetation. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The well has been fracked, and has a Christmas tree valve assembly. There are bull gates and concrete barriers surrounding the wellhead and cellar to prevent vehicle impacts. There are grates over the cellar to prevent falls. The mouse hole from drilling is still present, and has not been plugged. There is no production equipment at the site. The cellar is full of water to the top. Preliminary restoration approval will not be finalized pending installation of production equipment and re-inspection.
1036433271 2016-02-26 Production Wells No Violations I was on location for a status check. My inspection found the access road gate locked and the

access road in good repair. The pad is fenced and all man doors were locked. An identification sign is posted at the access road entrance and well. The #8H is not in production. The well is equipped with a christmas tree valve assembly. The equipment on the pad consists of the following:

Site fenced and man doors locked

1130357726 2012-11-06 Drill / Deepen / Reopen No Violations
1183579594 2012-11-27 Drill / Deepen / Reopen No Violations I went to the site to check on the rig move out. The rig and all equipment were gone from the site.
1355995844 2012-11-14 Drill / Deepen / Reopen No Violations I went to the site to review the drilling progress. The rig was tripping the drill pipe at a depth of 6172.
1431732226 2017-08-31 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-1749. The access road, pad and erosion and sedimentation controls were in good repair. The security fence was locked. No signs of vandalism were observed. Correct identification was present. The well head was protected by concrete jersey barriers. The cellar was open and contained water near free board. Annular pressure gauges were plumbed above grade and identified. The 9.625 and 5.5 valves were open. The 9.625 annular gauge indicated 0 psi. The 5.5 annular gauge indicated 260 psi. The well head was equipped with a Christmas tree valve assembly. Valves were closed, chained and locked. No leaks were detected. The well remained in temporary inactive status. No violations were observed during this inspection.
1704832102 2018-11-20 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-1749. Correct identification was present at the entrance. The road and well pad remained in good repair. The perimeter security fence remained in good repair and locked. The perimeter berm and slopes remained stable with well-established vegetation. The French drain stand pipes remained open. Correct identification was present at the well head. Jersey barriers were present to prevent a collision. Grates remained over the cellar to prevent falls. The cellar contained freshwater. No leaks were observed. Gauges to measure annular casing pressure were present and labeled. The 9.625 annulus indicated 0 psi. The 5.5 annulus indicated 240 psi. The 5.5 production casing wing valve gauge indicated 0 psi. The production tree cap gauge indicated 0 psi. All valves were chained, closed and locked. No production equipment was on location. No violations were observed during this inspection.
1831688801 2015-04-07 Production Wells No Violations

-established ground cover. The soil stockpile is well stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. I emailed Steve Ault of Chesapeake on 4/24/2015 about the identification signs. He replied on 4/27/2015 that they had located the wellhead identification signs and they would be installed within the week. I recommend temporary inactive status be granted.

1899253135 2012-10-04 Surface Facility Construction No Violations I went to the site to review the construction process of the drilling pad. Pad construction was complete.
2103669645 2012-11-23 Drill / Deepen / Reopen No Violations I went to the site to check on the rig move. The move out to the next location was underway.
2135977681 2016-12-06 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-1749. The well is currently in temporary inactive status. Correct well identification remains present at the entrance and well head. Lease access and the well pad facilities remain in good repair. No other equipment is on the pad. The Owner raised and identified the 9.625 intermediate annular casing pressure gauge and the 5.5 production annular casing pressure gauge. The intermediate annular casing gauge indicated 0 psi. The production casing annular gauge indicated 260 psi. Maximum allowable annular surface pressure (MAASP) at the surface per ORC 1501:9-1-08 (N) (2) is 462 psi. The production casing valve was closed. I will continue to monitor casing pressures on a regular basis to ensure compliance.
269622251 2020-4-28 0:00: TI No Violations 1.00
313990817 2016-6-21 0:00: PW No Violations 3.50
534738574 2019-5-29 0:00: TI No Violations 0.40
538214919 2012-11-7 0:00: DD No Violations
757675359 2013-8-20 0:00: PL No Violations

For data sources see[10]